CHEMCAD Seminar Transport and Storage John Edwards, P&I Design Ltd
January 2015 1
2
HANDLING AND STORAGE SESSION OBJECTIVES
Review energy balance theory Understand derivation of resistance coefficients Develop user resistance coefficients Control valve characteristics & sizing parameters Centrifugal pump sizing and rating Design and rate piping distribution networks Design and rate complex networks using Nodes Reference: Crane, “Flow of Fluids through Valves, Fittings and Pipes”, 410M Download:
3
HANDLING AND STORAGE FLUID FLOW BASIC THEORY
Continuity Equation Q volume flow a pipe area v velocity p pressure w density z height h line losses Bernoulli’s Equation Combining for p1= p2 and z1 = z2
4
HANDLING AND STORAGE CIRCULAR PIPE FRICTION FACTORS
Darcy Equation Form (CHEMCAD & CRANE 410M) L pipe length D pipe diameter f friction factor v velocity G 9.81 m/s2 Darcy > Fanning Friction Factor Fanning Friction Factor Equation Form
5
HANDLING AND STORAGE FRICTION FACTORS IN CHEMCAD
Jain Equation Solves Darcy Friction Factor Matches Colebrook equation within 1.0% for 10-6 < ε / D < 10-2 and 5000 < Re < 108 Jain is CHEMCAD default method Churchill Solution Validity Applicable for all values of ε / D and Re
6
MOODY DIAGRAM (DARCY f)
7
HANDLING AND STORAGE FRICTION FACTOR CORRELATIONS
Blasius more accurate for smooth pipe
8
CHEMCAD LOSSES IN PIPES AND FITTINGS ROUGHNESS COEFFICIENTS ε
9
Pressure Loss Coefficient Darcy Gradual Enlargement Kr
LOSSES DUE TO FITTINGS Pressure Loss Coefficient Darcy Gradual Enlargement Kr Entry to pipe K = 0.5 Exit from pipe K = 1.0 Sudden enlargement Sudden contraction L pipe length D pipe diameter f friction factor v velocity G 9.81 m/s2
10
CHEMCAD LOSSES IN PIPES AND FITTINGS DARBY 3K METHOD
11
CHEMCAD LOSSES IN PIPES AND FITTINGS
STANDARD L/D VALVE AND FITTING LOSSES FROM CRANE 410 USER SPECIFIED OPTIONS INCLUDE L/D Manufacturers’ data Kr Derived from orifice calculation KS Sudden expansion or contraction coefficient (Crane K1) 3K Darby Method Enter appropriate K1 Ki KD L/D methods tend to under predict friction loss for larger D pipes. 3K method is most accurate for all Re and fitting sizes.
12
TEES STRAIGHT AND REDUCING
“Tee Flow Thru Run” in pipe with largest flow rate L/D CHEMCAD=8.4 DARBY 3K=17 Flow-out Branch Flow-thr Run Flow-thr Run Flow-in Branch “Tee Flow Thru Run” CHEMCAD in both pipes Equates to DARBY 3K “Flow Out Branch” in branch pipe L/D CHEMCAD=58 DARBY 3K=51.2 “Flow In Branch” in branch pipe L/D CHEMCAD=43.2 DARBY 3K=51.2 UnitOp 1 UnitOp 2 UnitOp 3 Expansion Contractions always In smallest diameter pipe Unequal Tees install reducer in branch pipe UnitOp 1 UnitOp 2 UnitOp 3
13
CHEMCAD LOSSES IN PIPES AND FITTINGS
14
CRYOGENIC BATCH REACTOR OPTIMISATION
PIPE DESIGN ECONOMIC VELOCITIES CRYOGENIC BATCH REACTOR OPTIMISATION
15
ORIFICE PLATE TAPPINGS
2½D – 8D taps for flow restriction
16
EXPANSIONS AND CONTRACTIONS
17
CRYOGENIC BATCH REACTOR OPTIMISATION
FLOW SCALERS WITH PRESSURE NODES CRYOGENIC BATCH REACTOR OPTIMISATION Flows calculated from PIN and POUT Pipe (PIPE) Valve (VALV) Control Valve (CVAL) Pump (PUMP) Compressor (COMP) Expander (EXPN)
18
CRYOGENIC BATCH REACTOR OPTIMISATION
PIPE NETWORKS - NODES(CALCULATORS) CRYOGENIC BATCH REACTOR OPTIMISATION All Network Flows and Pressures are interdependent Junction pressures are equal and flows balance Flows are calculated as a function of : Inlet Pressure (Pin) & Outlet Pressure (Pout) Flow Scalers calculate flow as a function of : Nodes link all Flow Scaling UnitOps Elevation of node entered > elevation change calculated
19
PUMP NPSH
20
PUMP NPSH
21
PIPE SYSTEM SIMPLE DESIGN
Case 5.03 Piping Design Section 5-p155 NPSH Nett Positive Suction Head
22
PIPING SYSTEM DESIGN CASE 5.03
Case 5.03 Piping Design Section 5-p155 Objectives Pipe UnitOp Pump UnitOp Elevation change Pipe size(p121) Suction ft/s Diam 4 in Discharge 10 ft/s Diam 3 in Simulation Basis Units English Component Glacial Acetic acid Thermo H – UNIFAC L - LH Feed Stream Q 220 gpm T 70°F P 20 psia Discharge P P > 20 psia T 140°F Pump Discharge T o be determined
23
PIPING SYSTEM DESIGN CASE 5.03
Case 5.03 Piping Design Section 5-p155 Objectives Pump selection 1.Manual method 2.Controller Pipe UnitOp Mode Single phase Sizing Rating Pipe Schedule Default Schedule 40 (p548) Size Determined by velocity Roughness Commercial steel Friction Churchill Elevation change Down – Negative Up - Positive Pump Discharge Initial trial 60 psia η 0.8 (Refinery p66)
24
PIPING DESIGN USING NODES CASE 5.04
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158
25
PIPING DESIGN USING NODES CASE 5.04
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158 Piping design Deliver acetic acid 120 gpm 70 deg F at 20 psia to process Nodes Set inlet state Set elevations Set outlet state Flow scaler Here the pump Calculates Flow
26
PIPING DESIGN USING NODES CASE 5.04 INLET AND OUTLET NODES
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158 Inlet Node Outlet Node
27
PIPING DESIGN USING NODES CASE 5.04 PIPE FLOW AS FLOW SCALER
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158 Allows Flow to be set by UnitOp
28
PIPING DESIGN USING NODES CASE 5.04 NODE BETWEEN FLOW SCALERS
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158 P set Variable or Fixed Flow set Fixed or Variable Boundaries for the pressure
29
PIPING DESIGN USING NODES CASE 5.04 PUMP PERFORMANCE CURVE
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158
30
PIPING DESIGN USING NODES CASE 5.04 NODE BETWEEN FLOW SCALERS
Case 5.04 Pump Sizing and Pipe Branches Section 5-p158 Excel Data Map Facility for Key Data Reporting
31
Piping Design and Rating
Simulation of more complex piping systems, as found in service distribution networks, to determine the pressure drops and the flows throughout the system. This case develops the design of a cooling water distribution system supplying three shell and tube heat exchangers. CASE 5.05 COOLING WATER SYSTEM PIPING SYSTEM RATING Piping Design and Rating Case 5.05 Cooling Water System Section 5-p163 Simulation Basis Units Common SI Component Water Thermo H – Ideal Vapor Pressure L - LH Feed Stream W kg/h T 15°c P 5 bar Heat Exchanger Duties 50 kW 100kW 150kW Heat Exchanger ∆P 0.5 bar Piping Design 3 m/s allow for upgrade to kg/h Restriction Orifice 0.5 bar pressure drop in spillback line Control Valve Sizing Flow based on 150kW POUT 3.5 bar Control valves are adjusted manually to achieve required duty
32
Piping Design and Rating
PIPING SYSTEM RATING CASE 5.05 Piping Design and Rating Case 5.05 Cooling Water System Section 5-p163
33
Piping Design and Rating
CASE D2.04 DYNAMIC TANKER OFFLOAD Piping Design and Rating Case D2.04 Road Tanker Offload Section 2-p25
34
Piping Design and Rating
CASE 5.02 VALVE SIZING TWO PHASE FLOW Piping Design and Rating Case 5.02 Control Valve Sizing and Flow Split Section 5-p152 Liquid NH3 225 psig -9 deg F Flow lb/h 50% split to two users 15 psig -1 deg F 0.2 psig -28 deg F Size control valves