Recent Result for the STF-2 Cryomodule Operation

Similar presentations


Presentation on theme: "Recent Result for the STF-2 Cryomodule Operation"— Presentation transcript:

1 Recent Result for the STF-2 Cryomodule Operation
T. Dohmae, M. Egi, K. Hara, T. Honma, E. Kako, Y. Kojima, T. Konomi, T. Kubo, T. Matsumoto, T. Miura, H. Nakai, K. Nakanishi, G. Park, T. Saeki, H. Shimizu, T. Shishido, T. Takenaka, K. Umemori, Y. Yamamoto Kirk 07/Dec/2016

2 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

3 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

4 STF Cryomodules 4 cavities per batch STF Cavity Package 07/Dec/2016
STF-1 (4 cavities) in 2008 S1-Global (4+4 cavities) in 2010 4 cavities per batch Proc. in SRF2011 Proc. in SRF2009 STF-2 (12 cavities) in 2014~ STF Cavity Package Quantum Beam (2 cavities) in 2012 Capture CM in STF-2 accelerator Proc. in IPAC12 WEPMB017 in IPAC16 07/Dec/2016

5 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

6 Brief History for STF-2 Cryomodule
Date Content 2011 ~ 2013 V.T. for 12 cavities / RF conditioning for 12 couplers Jun/2013 Cleaning up STF tunnel Jul/2013 ~ Apr/2014 Cavity string assembly (three times) Oct/2013 ~ Jan/2014 Module assembly (CM1/CM2a) Jul/2014 Complete certification for High pressure Gas Code Oct/2014 ~ Dec/2014 1st cool-down / low power test Apr/2015 ~ Jul/2015 5MW Klystron / Single waveguide system completed Jul/2015 ~ Sep/2015 Coupler conditioning at room temperature Oct/2015 ~ Dec/2015 2nd cool-down / high power test Jan/2016 ~ Jul/2016 Multi-beam Klystron & Waveguide system completed Jul/2016 ~ Sep/2016 Sep/2016 ~ Nov/2016 3rd cool-down / LFD, Q0 measurement, 8 Cavities Operation & LLRF study F.Y. 2017 4th cool-down test (?) F.Y ~ Beamline construction / Beam operation starts (?) 07/Dec/2016

7 Brief history of STF-2 project
07/Dec/2016

8 STF-2 Accelerator Layout
To be constructed CM2a Cold box CM1 View from downstream Waveguide system Capture CM To be constructed Cold box Chicane RF Gun View from upstream 07/Dec/2016

9 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

10 Performance for STF-2 Cryomodule
RF conditioning was done very carefully as monitoring heating at HOM couplers, unusual RF output from HOM couplers, and radiation level. Short pulse  Full pulse  Long run STF-2 RF Parameters QL : 5.0 x 106 Filling time : 900μsec Flat-top : 100μsec (short pulse) Flat-top : 800μsec (full pulse) Total width : 1700μsec First and third cavity string achieved “No degradation” in CM test. (Q0 measurement will be done from this autumn) Second had significant trouble (heavy field emission) due to additional (and irregular) clean room work (probably). 07/Dec/2016

11 Performance Degradation
Statistics for cavity performance; Above 31.5 MV/m: 11 cavities Degradation: 4 cavities Three types of performance limit; One cavity: Quench w/o F.E. Two cavities: F.E. Quench One cavity: Quench by enormous heat loss Three degraded cavities in STF-2 are connected in series.  Common cause for degradation Q0 measurement is not done yet in STF-2. It will start from this autumn. Heavy F.E. in V.T. 22 cavities in 6 cavity strings Statistics for cavity string (four cavities per batch); Four cavity strings: No degradation Quantum Beam: Degradation, but around ILC spec. CM-1b in STF-2: Significant degradation 07/Dec/2016

12 Cavity string/Beam pipe connection in Tunnel
Local clean booth Ion pump Ion pump Three degraded cavities in series Use of simply local clean booth Local clean booth was used for four beampipe connection parts Exchange of metal valve near cavity string #2 Metal valve was a little bit bigger, disturbed thermal shield attachment Extra Argon gas purging at gate valve opened Usually, when gate valve opens, both sides should be under vacuum but, we had to do Argon gas purging for the both sides due to complicated process of cryomodule assembly 07/Dec/2016 A little bit bigger metal valve

13 Improvement of clean room items
Many experiences in High quality local clean booth Slow pumping system High quality particle counter Ultrasonic rinsing for ion pump Will be introduced in 2017(?) 07/Dec/2016

14 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

15 8 Cavities Operation by Vector-sum @31MV/m
Preliminary result 8 Cavities were tuned on resonance by piezo, and stable vector-sum operation was done at 31MV/m. 07/Dec/2016

16 Q0 – Eacc Curve in STF-2 CM Miss! Q0 was uniformly lowered?
Lower Q0 is not related to F.E. Main error is generated from reproducibility of static heat load and distribution of helium mass flow Data analysis is still on-going (To be presented in TTC Meeting at MSU) 07/Dec/2016

17 Comparison of Q0 – Eacc Curve between V.T. and C.T.
Light F.E. Preliminary result Heavy F.E. 07/Dec/2016

18 Outline Progress of STF Cryomodules Brief History of STF-2 Cryomdoule
Result from 2nd Cooldown Test in 2015 Result from 3rd Cooldown Test in 2016 Summary & Future Plan 07/Dec/2016

19 Summary STF-2 cryomodule test have been done three times since 2014
Eight cavities achieved above 31.5 MV/m as ILC spec. Three cavities had significant degradation from V.T. One cavity already had heavy F.E. in V.T. 8 cavities operation was successfully done at 31MV/m Vector-sum control by LLRF was used LFD compensation by Piezo drive was perfectly done Two cavities in Capture CM were also simultaneously operated Q0 in 3rd cooldown test was uniformly lowered from V.T. Data analysis and investigation are still on-going Static Heat Load was significantly large 07/Dec/2016

20 Future Plan 4th cool-down test is done in F.Y. 2017 (?)
Beamline construction is done in F.Y (?) Beam commissioning starts from F.Y (?) 07/Dec/2016

21 Thank you very much for your attention
We will present the detailed result for 3rd cooldown test in IPAC17 and SRF2017! 07/Dec/2016

22 Back-up slides 07/Dec/2016

23 Additional items for beam commissioning
Multi-beam Klystron (10MW) Waveguide system for eight cavities Pumping unit for 2K liq. helium Quadrupole magnet system 07/Dec/2016

24 Radiation level near Cryomodule
Position of radiation detector: Upstream beampipe Downstream beampipe Below cryomodule (cavity) Radiation property: Cavity #5 & 7: Heavy F.E. Cavity #6: No x-rays, but enormous heat loss Cavity #9: Heavy F.E. already in V.T. 07/Dec/2016