Download presentation
Presentation is loading. Please wait.
3
HEPA and ULPA Filter Testing
Presented By Charlie Kwiatkowski PFS Sales & Product Manager Purolator Air Filtration Kenly, NC
4
Topics Of Discussion DOP Efficiency Tester Q-107 Dual Laser
Leak/scan Testing Particle Counters High Efficiency Air Filters Fire Resistance Summary
5
DOP Efficiency Tester (Q-107)
Developed 1940s Guaranteed Performance Efficiency Pressure Drop Upstream Aerosol Hot DOP (Dioctlyphthalate) A Non Destructive Test
6
Q-107 Penetrometer
7
Dual Laser Efficiency Developed Late 1970’s Non Destructive Test
Counts Size & Individual Particles Filter Pressure Drop
8
Dual Laser Efficiency This machine has the ability to see particles that are .1 and larger (12) separate bins (Particle Sizes) that can be looked at. This machine will use PSl’s clean challenge.
9
Leak/Scan Testing Non Destructive Test Locate Gross Leaks
Photometer or Particle Counter Manual Autoscan Cleanroom Applications
10
Autoscan A Non-destructive Test to Locate Leaks
Particle Counter Method Removes Operator Variability
11
Particle Counters Monitor Dust/Particles Determines Particle Size
Scan Test Incandescent Light .3 Micron Laser Light .07 Microns
12
Higher Efficiency Air Filters
HEPA (High Efficiency Particulate Air) 1940s .3 Micron ULPA (Ultra Low Penetration Air) 1970s MPPS SULPA (Super Ultra Low Penetration Air) 1980s MPPS
13
Fire Resistance UL 900 (Fire Retardant)
Class 1 (Minimum Smoke & Flame) Class 2 (Moderate Smoke & Flame) UL 586 (Performance) Exposure To Heat & Flame
14
Summary DOP Tester Q-107 Penetrometer/Dual Laser Cold DOP Testing
Pin Hole Leaks Particle Counters Particle Size High Efficiency Air Filters HEPA (High Efficiency Particulate Air) ULPA (Ultra Low Penetration Air) SULPA (Super Ultra Low Penetration Air) Fire Resistance UL 900 UL 586
15
Questions