Presentation is loading. Please wait.

Presentation is loading. Please wait.

Date of download: 9/26/2017 Copyright © ASME. All rights reserved.

Similar presentations


Presentation on theme: "Date of download: 9/26/2017 Copyright © ASME. All rights reserved."— Presentation transcript:

1 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: (a) Schematic cross-sectional view of the nominal material stack considered for thermal analysis. Microfluidic cooling channels are etched in a ⟨100⟩ silicon wafer, which is subsequently bonded to a ⟨111⟩ silicon wafer. GaN has a better lattice match to ⟨111⟩ silicon and is subsequently grown as a thin layer on top using molecular beam epitaxy (MBE). (b) Nominal device layout and geometry for a multifinger GaN HEMT (designed by Raytheon Technologies, Andover, MA). The HEMT comprises ten gate fingers, which are 100 μm long and 1 μm wide, pitched at 40 μm apart (center-to-center). There are five drain fingers that are 30 μm wide each, and two source bridges that are 40 μm wide each. (c) Schematic view showing the position and dimensions of the heat sources representative of the multiple GaN HEMT fingers, used for the numerical simulations. (d) Geometry of the 3D model comprising multiple cooling channels underneath a multifinger HEMT (representative of a discrete GaN transistor) when the length of the HEMT fingers (i.e., the direction of gate “width”) is kept parallel to the length of the microfluidic channels and (e) perpendicular to the length of the microfluidic channels. (f) and (g) The FE mesh for the geometries shown in (d) and (e), respectively. The finest mesh elements are used near the fingers where the heat is concentrated.

2 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Temperature distribution in the entire material stack upon solving for combined laminar flow and heat transfer problem using FEA in comsol multiphysics for (a) the parallel finger configuration and (b) the perpendicular finger configuration. The dimensions of the material stack are in micrometer, and the temperature values are in degree Celsius. The top views of the stack showing the temperature distribution near the HEMT finger regions are seen for the parallel and perpendicular orientations in (c) and (d), respectively. YZ isothermal plots showing variation of temperature along the depth of the stack, at an X-axis cross section location at the center of the HEMT fingers, are seen in (e) and (f), for the parallel and perpendicular orientations, respectively.

3 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Finger–finger variation in temperature with and without cooling for the cases when (a) gate width is kept parallel to the length of the microfluidic channels and (b) gate width is perpendicular to the length of the microfluidic channels. (c) Compares the cooling efficiency of the two design arrangements on the same axes. Much smaller finger–finger temperature variation is observed in the parallel case upon cooling. Temperature variation along the width of the center finger (hottest) is shown in (d) for both the parallel and the perpendicular cases upon cooling. Finger–finger variation in temperature for (e) gate width kept parallel to the length of the microfluidic channels and (f) gate width perpendicular to the length of the microfluidic channels, while varying spacing between heat sources, between 10 and 50 μm. Higher peak temperatures are observed in the thermal stack for tighter finger spacing, for both the cases.

4 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Temperature rise along the direction of depth below the hotspot for the cases when (a) gate width is kept parallel to the length of the microfluidic channels and (b) gate width is perpendicular to the length of the microfluidic channels. The ⟨111⟩ silicon layer offers a high thermal resistance. The majority of the temperature drop occurs across the microfluidic channels with effective heat removal from the GaN hotspots.

5 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Finger–finger variation in temperature for (a) gate width kept parallel and (b) perpendicular to the length of the microfluidic channels, while varying distance of heat sources from fluid inlets from 100 to 1000 μm. In both the cases, higher peak temperatures are observed for larger distances from fluid inlet. Variation in temperature while varying depth of the cooling microchannels and keeping the flow rate fixed for (c) gate width kept parallel and (d) perpendicular to the length of the microfluidic channels. Variation in temperature while varying the thickness of the ⟨111⟩ silicon layer above the cooling microchannels for (e) gate width kept parallel and (f) perpendicular to the length of the microfluidic channels. The peak temperature in the material stack decreases very slightly with the increase in the thickness of silicon, for both the cases considered.

6 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Simulation results for pressure drop obtained at (a) a nominal inlet flow velocity of 1000 mm/s for design 1 for inlet and outlet manifold regions, (b) inlet flow velocity of 5000 mm/s for design 1, (c) nominal inlet flow velocity of 1000 mm/s for design 2 for inlet and outlet manifold regions, and (d) inlet flow velocity of 5000 mm/s for design 2. (e) Peak temperature at any point in the material stack considered, as a function of the Reynolds number for the flow, for both the geometry variations of the gate width parallel as well as perpendicular to the length of the microfluidic channels. The channel width and depth are kept constant at 20 μm, with finger spacing of 30 μm. The rate of drop in peak temperature is observed to be nearly the same for both the cases, regardless of the HEMT orientation. Much lower temperatures are observed in the stack for higher Reynolds number values, corresponding to higher inlet flow rates, resulting in higher cooling efficiency.

7 Date of download: 9/26/2017 Copyright © ASME. All rights reserved. From: Modeling and Analysis for Thermal Management in Gallium Nitride HEMTs Using Microfluidic Cooling J. Electron. Packag. 2016;139(1): doi: / Figure Legend: Simulation results obtained with the adiabatic boundary condition at the base of the ⟨100⟩ silicon substrate and power density of 2 W/mm when (a) gate width is kept parallel and (b) perpendicular to the length of the microfluidic channels, for the nominal cooling system configuration. Finger–finger variation in temperature for (c) gate width kept parallel and (d) perpendicular to the length of the microfluidic channels, while varying spacing between heat sources, between 10 and 50 μm for this case. (e) Peak temperature at any point in the material stack considered, as a function of the Reynolds number for the flow, for both the geometry variations of the gate width parallel as well as perpendicular to the length of the microfluidic channels.


Download ppt "Date of download: 9/26/2017 Copyright © ASME. All rights reserved."

Similar presentations


Ads by Google