Presentation is loading. Please wait.

Presentation is loading. Please wait.

REFINARY & PETROCHEMICAL

Similar presentations


Presentation on theme: "REFINARY & PETROCHEMICAL"— Presentation transcript:

1 REFINARY & PETROCHEMICAL
Applications Sea Water Lines Pipelines Coke Drum Cyclones Vessels & Column Exchangers & Condensers Flare & Stacks Storage Tanks Compressor Pumps & Values Turbines & Gear Box Reactors Bed Weld-o-let for Penetration Transformers Heater Tubes

2 PTZ CAMERA SYSTEM

3 Application REFINERY & PETROCHEMICAL 12 Sea Water Lines
Major Components 1 Coke Drum 2 Column 3 Crude Unit 4 Catalytic cracker 5 Fractionation Tower 6 Storage Tanks 7 Spheres 8 Railroad Tank cars 9 Transformers 10 Flare Specific Components 1 Reactors Bed 2 Heat Exchangers 3 Fin Fans Coolers 4 Boilers & Furnace 5 Pressure Vessels 6 Tower Trays 7 Cyclones 8 Piping 9 Compressors 10 Gear Box 11 Pump & Valves 12 Sea Water Lines

4 PTZ CAMERA SYSTEM

5 Application REFINERY & PETROCHEMICAL Major Components
Tank Floor Scanning (SLOFEC) Boilers (RFET) Furnace (RFET) Exchangers (ECT) Fin Fan Coolers (RFET) Piping (RFET) Insulated Piping (RFET) Sphere Legs (RFET) Sea Water Lines (Leak Detection)

6 PUSH CAMERA SYSTEM

7 Application POWER PLANT Wind Mill 12 Gear Box 13 Wind Mill Blades
Remote Visual of Thermal Power Plant 1 Steam & Gas Turbine 2 Generators 3 Extraction & Oil Line 4 Main Steam Piping 5 Headers 6 Blade & Nozzle 7 Value Inspection 8 Feedwater Heaters 9 Transformers 10 Stacks 11 Condenser RFET 1 Water Wall 2 Drum to Drum tube 3 Economizer 4 Super Heater 5 Re-Heater Wind Mill 12 Gear Box 13 Wind Mill Blades Hydro Power Plant 14 Tunnel 15 Bore Hole

8 REVOLVING CAMERA SYSTEM

9 Application DEFENCE Sea Tubes Inspection (RVI)
Sea Chest Inspection (RVI) Turbine & Gear Box Inspection (RVI) Boiler tube Inspection (RFET & RVI) Hull Inspection (SLOFEC) Piping Inspection (RFET) Deck Inspection without removal of Microtech coating (RFET) UT Thickness Mapping Aircraft Engine Inspection (RVI) Barrel Inspection of Gun (RVI)

10 CRAWLER CAMERA SYSTEM

11 Application MUNCIPAL CORPORATION Remote Visual Inspection Water Lines
Sewer Line Strom Water Lines Tunnels Man Hole Leak Detection in Water lines Utility Mapping Rehabilitation of Sewer & water mains Micro Tunneling

12 REMOTE FIELD ELECTROMAGNETIC TESTING

13 Application BOILER - RFET Boiler Water Wall Inspection
APPLICATIONS Boiler water wall Inspection Boiler Drum to Drum Tubes Economizer Tubes Super Heater & Re-Heater tubes Furnace Tubes Bare & Coated Piping Insulated piping upto 2” insulation Sphere Legs & Vessel Skirt Heat Exchangers Fin Fan Cooler Tubes Boiler Water Wall Inspection 100% inspection of tubes Travel 40mtr vertically on water wall. Minimum scaffolding is required 5 Tubes can be scanned simultaneously Minimum Cleaning is required Dual frequencies are used 10% wall loss can be detected Equally sensitive to ID and OD defects Real time Inspection can be done Tubular (Boiler & Exchanger) Inspect tubes having ID as small as 0.25” (6.35mm) to tubes of 3” (76.2mm) 60-75% Fill Factor probes can be used for inspection Dual frequency enables to detect defect under Baffle Can differentiate between relevant and non-relevant signal Special Flexible probes for boiler drum to drum inspection

14 Defects : Fatigue (Thermal) Crack Capacity : 250Mw Material :
MAHAGENCO, Bhusawal Defects : Hydrogen damage & Corrosion Pitting Capacity : 250Mw Material : Tube size : Observation : RFET was carried out in selected area around Burners. Localized wall loss like Hydrogen damage, pitting & Bulges were observed. Conclusions : Later the tube were dissected and the given defects were confirmed Tata Power, Jamshedpur Defects : Fatigue (Thermal) Crack Capacity : 250Mw Material : Tube size : Observation : RFET was carried out in selected area around Burners. Severe Indication was observed. No wall was observed. Conclusions : UT scanning was carried out indication reflect the suspect of Thermal (Fatigue) cracking. Later metallurgical test was carried out and it was confirmed that tube has Thermal Cracking

15 MEW, Kuwait Defects : Bulging Capacity : 250Mw Material : Tube size :
Observation : 100% inspection of water wall was carried out using RFET. Localized severe indication were observed. No wall loss was observed and no corrosion or visual defect was observed. Conclusions : Later the tube were inspected using focused high beam light and Bulging were found visually. Later in metallurgical test deformation was confirmed. HPGCL, Yamunanagar, Haryana Defects : Pitting Capacity : 250Mw Material : Tube size : Observation : Inspection carried out on Riffle tube Found Localized Pitting in most of the Tube . Later the tube were cut opened for confirmation and pitting were observed visually. Nearly 250 of tubes were replaced Conclusions : Later the tube were dissected and the given defects were confirmed .

16 SATURATED LOW FREQUENCY ELECTROMAGNETIC TESTING

17 Application Tank Floor Scanning - SLOFEC
Capability of inspecting ferromagnetic and non-ferromagnetic materials High defect detection sensitivity and reliability Distinction between external and internal defects Detect defect of smooth couture Wall loss of 10% can be detected Works on Coated (8mm) Tank Floor Inspect close to tank wall & weld ie minimum dead zone 25mm High inspection speed (30mtr/min) High inspection temperature range (Piping) Minimum cleaning ie Hydro jetting is required Power Supply: 220 & 110Volts. Can also work with 36Volt power supply Capability of real time scan results with coloured defect mapping Complete C scan of Tank Floor can be given with exact Location, Wall loss & Defect side Internal or External Side rollers for driving along the tank wall LED for visual inspection