Studio 5000 Logix Designer ®
V27- V28 Features Chris Como Product Manager – Studio Logix Designer
2
Studio 5000 Capabilities Going Forward
Logix Designer View Designer Architect Application Code Manager Making a more collaborative environment with specific focus on workflow and re-use.
3
V27 Studio 5000 Logix Designer
View Designer Integration
4
V27 Logix/View Features Logix & View Shared Tag Definitions Extended data around tags & structures – “Meta Data” High Speed Button Control Jog Motor A-B Controller Based Alarm Log
5
V27 High Speed HMI Button Control
New Logix and View Communications method New instruction in Logix that HMI will interact with High speed deterministic communications similar to I/O Benefits Reduced lag and improved accuracy for manual jog operations from traditional HMI More flexible than physical buttons with comparable performance Eliminates need for custom logic to verify active communications Jog Motor A-B Logix detects comms failure and automatically resets the button request Considerations: When a Jog instruction and button are used, the controller establishes a Class-1 connection to the terminal. This is similar to how I/O are communicated and can provides a high speed link to exchange data ever ~50msec with determinism and failed communications shutdown. However, to avoid the user having to think about the mapping of jog operations to bits within an I/O tag, the controller and terminal interact with each other to establish a communications link over the class-1 connection. This way you get the benefit of the class-1 communications without the hassle of having to keep everything linked up via I/O tags. One side effect of this is that only the new Rockwell HMI platform will be able to leverage the jog instruction to control machine operations. The more tradition approach to jog control via bit mapping will be required for Legacy and competitive HMIs. While the new communications ensures a speedy exchange of data it is still possible that an HMI that is loaded with a very large application could result in delays within the terminal. This could result from large complex screens and asynchronous tasks being performed on the terminal. This type of impact would only effect a small percentage of applications. Because of how the controller interacts with the Jog instruction’s tag, the tag can only exist at program and controller scope (similar to an Alarm instruction). However, it can be passed into an AOI via an InOut parameter. Additionally, the new Meta Data capability will permit the InOut tags to be referenced via the AOI tag reference so you can create an Add-on Graphic that points at the AOI tag and the AOG will be able to obtain the Jog tag referenced by the AOI invocation. June 13, 2011
6
V28 Studio 5000 Logix Designer
ControlLogix® 5580 Controller
7
ControlLogix® 5580 Controller
Control Focused on Logix Machine Performance Helps Enable faster system performance Future proofing Your System and enabling The Connected Enterprise Onboard display 1GB Embedded EtherNet/IPTM port enables high-performance I/O and Motion control Controller Task Monitor / Embedded Web Page Up to 45% Increased memory capacity Improved performance and throughput Studio 5000, Version 28 Support Digitally signed and encrypted Controller firmware Controller-based Change Detection and logging Role-based access control to routines and Add-On Instructions Smart Productive Secure
8
V28 Studio 5000 Logix Designer
5069 Compact I/O
9
5069 Compact I/O 1 Adapter, 14 Modules EtherNet/IP Adapter AENTR
Input - 24Vdc IB16 IB16F IB6F-3W Output - 24Vdc OB16 OB16F Input – Analog/Temperature IY4 IF8 Output – Analog OF4 OF8 Output – Relay Isolated OW4I OX4I High Speed Counter HSC2xOB4 Field Power Distribution FPD Address Reserve ARM
10
Channel Level Data Structure
Digital Analog All information associated with a channel is contained within the channel structure Data structures have been “future proofed” by allocating reserved bits for new features The addition of the “Health” status provides for a single check to determine the validity of the data Each “Health” status is a 2 bit field providing 3 data states Good Uncertain Faulted A transition of the “Health” status will rollup and trigger the diagnostic counter to increment Future proofing: Meaning that the code within Logix Designer will not have to change going fwd to adapt new HW. We are standardizing on this structure going fwd to allow a much easier and robust way of adopting new HW.
11
Logix Designer Notable Mentions
Small, yet important improvements…
12
Sequential Function Chart Editor
V27 Keyboard Shortcuts for Quick Navigation Ctrl Home Ctrl End On a per sheet basis. So if you have multiple sheets it will be in reference to the active sheet.
13
UDT Editor Copy and Paste from External Sources V27
Right Mouse Click icon Returned Ability to Copy and Paste from Excel into UDT Editor
14
Ladder Editor CPT Instruction Dialog V27 Previously Updated
Original Expression visible and Pop Up Dialog able to be moved Expression Hidden by Pop Up Dialog Original Expression in the CPT Expression visible when expression editor is opened
15
FBD Editor Re-order Sheets Organize Sheets Now Sheet 2
Re-Order then Click OK
16
General Editor Identification of Called Routine By Active Power Rails
No JSR for “WS1_SpdRef” Routine No Green Power Rails Routine will not show green power rails when: No Appropriate JSR to call the routine If the Program it is contained in is “Inhibited” Will NOT flicker On and Off with actual execution but rather looks at the call to the routine to make sure that it can be jumped to or executed.
17
No JSR for “fbd” routine
General Editor V28 Determination of a “Lonely Routine” During Project Verification No JSR for “fbd” routine Warning Message During Verify Right now in V28 this is ALWAYS ON and will still search the Unscheduled Program Future will add the ability to turn off Warning completely OR in the unscheduled Task only. During project verify locate routines with no corresponding JSR (Jump to Subroutine)
18
Logical Organizer Locating Routines/Programs Easier Between Organizers
V28 Locating Routines/Programs Easier Between Organizers Launches Logical Organizer Navigates to the Context you Searched from Bi-directional Right Mouse Click icon Find
19
Structured Text Editor
V28 Customized Comment Header Include Header on Create Auto-Create Customized Header Need to add future capability to auto insert the Routine name and Author, and Date with the Syntax as <> which is used for the SW to dictate an insertion is needed. Customizable Header for Consistent Structured Text Routine Documentation
20