CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS

Similar presentations


Presentation on theme: "CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS"— Presentation transcript:

1 CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS

2 Mobile (Container) DC Container DC is a method of deploying data centers that is designed to add data center capacity and to reduce an organization's cooling and power consumption costs Builds on capability of integrating cabinets, cooling, electrical distribution, sensors, and fire suppression systems into a single package

3 Why Container DC ? Rugged Containers Reduced CAPEX Energy Efficient
Plug & Play Relocatable Fast time to execute Minimal use of space All in one DC

4 Canovate Mobile Data Center

5 From Concept to Reality

6 40 Foot Container painted to customer requirements.
4 by 28 KW outside compressor & condenser units supporting 4 DX based in row cooling systems. DX based eliminates links to a chiller. Caged for unauthorized access.

7 ROXTEC cabling entrances to ensure IP 65 rating.

8 Generator Unit Diesel generator based on customer requirement KW supplied based on customer requirement.

9 Sealed Entrance Door

10 Entrance Door Sensors Video based entry detection connected to EMS system for secure access. Smart card reader also installed with link to EMS system

11 Cold and hot aisles

12 Cold Aisle Sealed Cold Aisle Removable Panels 10 Cabinets
42U 600 * 1000 4 In Row Coolers Single 80% Perforation Doors Cold Aisle

13 Hot Aisle Sealed Hot Aisle Removable Panels
Double 80% Perforation Doors Hot Aisle

14 Cabinet interiors

15 Cabinet with Mounting Rails and PDU’s
Two PDU’s with Per Outlet Power (POP) switching 1500 KG Static Load AL Frame A and B feed for redundancy Monitored by EMS system Cabinet with Mounting Rails and PDU’s Depth adjustable mounting rails included

16 IP PDU’s with POPS Feature
Per Outlet Power Sensing and Control  Integrated temperature and humidity sensors Wireless sensor connectivity -up to 9 sensors Industry leading accuracy level: 97% accuracy in measuring Camera connection capability 16

17 Cooling units

18 COLD AISLE CONTAINMENT + Gas Based DX (Refrigerant R 410) Front Cooler
28 kW cooling capacity in 42U 300x1000 Cabinet Automatically controlled between 11 to 28 kW by inverter technology for maximum energy efficiency COP ratio is above 4 for maximum energy efficiency External Compressor unit to have better noise level Cooling units work 100% sensible (without condensed water) Specially developed for cold & hot aisle containment applications Modular construction In-Row cooling technology Eliminating raised floor requirement Variable speed fans: EC-Technology Modular design: Allowing capacity expansion Hot-swappable fans Multipoint Injection System

19 Cooling Units N + 1 Redundant Design. (3+1)

20 Cooling Controller and Monitor
Speed, alarms, thresholds

21 Hot Swappable Fans

22 sensors

23 Smoke Temperature, Humidity Sensors

24 Air Flow Sensor Opposite each In Row unit, additional check for fan performance

25 . Water Sensor Rope type water sensor

26 Environmental Monitoring System
Designed to monitor the working environment and control access to electronic equipment in racks and data center applications Real time monitoring through LAN or WAN Monitoring technique based on SNMP Precision air conditioning system monitoring and management Security system monitoring Fire protection system monitoring and management Power consumption statistics and analysis Monitoring Master Unit Monitoring Master Unit with outlets

27 SNMP Environmental Monitoring System

28 Electrical

29 Modular UPS Solution Online Double Conversion
Power rating ranges from 25kVA to 250kVA Possibility to connect two frames parallel to reach maximum 500KVA power Modular Design using hot-swappable power modules Intelligent Battery Management by DSP Intelligent Protection System 29

30 Modular UPS System Control Panel

31 Modular Power Distribution Panel
Modular and Scalable Capacity up to 3200 A Shock-Safe Adding extra circuit without prior scheduling Temperature control Dielectric properties Short-circuit withstand Electrical distribution panel can be configured according to your datacenter power requirements 31

32 Electrical Distribution System
Generator feeds EDS, power distributed to A and B UPS systems, from UPS, to IP PDU and In Row Cooling Electrical Distribution System

33 Fire suppression

34 Fire Suppression System

35 Fire Suppression System

36 Fire suppression nozzle – two each aisle

37 Battery backup

38 Battery Backup Cage

39 deployment

40 Ready for Deployment

41 Ready for Deployment

42 THANK YOU FOR YOUR ATTENTION
QUESTIONS? 42