2017 CALACT Maintenance Forum
IntelligAire III & ClimaAire 1D Presented by: James Cole Western Region Service Manager – Bus HVAC
2
IntelligAire III Monitoring Screen
3
CanDiag Diagnostic Kit 204-1927
Laptop PC requires Windows® XP, Windows® 7
4
USB/CAN ADAPTERS New Version Old Version
5
Installing CanDiag Must have administrative rights and internet access to properly install Uninstall previous versions of CanDiag before installing version 1.6.0
6
CanDiag Icons
7
Diagnostics
8
Updating CanDiag Issue with CanDiag update link
9
CanDiag Firmware Version
10
IntelligAIRE III Updating & Firmware
Updating CanDiag & Firmware
11
IntelligAIRE III Updating CanDiag & Firmware
12
Updating CanDiag Issue with CanDiag update link
Contact James Cole at the Thermo King booth, or for temporary link until issue is corrected in program
13
CanDiag Setup
14
IntelligAire III Login
service irkolin
15
Custom Password 1) Left click on down arrow and hold
2) Drag cursor down to ‘change password’ 3) Release
16
Diagnostics
17
Module selection Main Module ID0 0 Main Module ID0 1 Main Module ID0 2
18
Module Screens Real Time Data Programmable Features & Test Modes Alarm
Codes Energized Outputs
19
IntelligAIRE III Configuration Files telligAIRE III
20
IntelligAIRE III Configuration Set Up telligAIRE III
21
IntelligAIRE III Configuration Set Up telligAIRE III
22
Flash Load/Configuration Files
IntelligAIRE III Can DIAG Flash Load/Configuration Files
23
IntelligAIRE III Configuration Files
24
DEMO
25
IntelligAIRE III IntelligAIRE III Sensor Calibration
26
Firmware Flash Load Cables
27
Bench Loading IntelligAire III Firmware
28
Bench Loading IntelligAire III
24v or 12v Power Supply
29
Warranty Procedure 41-9353 Main Module
30
EEPROM Backup
31
Service Bulletin 572-28 Firmware Revision 04.00.00
32
Firmware Cable Port Identification
33
Introduction to IntelligAIRE III
Flash Loading/Com Port Set Up Introduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN Start (lower left on desktop) Devices & Printers
34
Thermo King, Bus Service Manager
IntelligAIRE III Flash Loading/Com Port Set Up troduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN
35
Flashloading / Com Port Set Up
IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 P4 P2 P6
36
Flashloading / Com Port Set Up
IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 Cycle power to complete flashload P4 P2 P6
37
Shutdown Alarm Lockout
SB645-1 3 alarm events in 100 hour increments 17 possible shutdown codes Separate counter for each code Code 49 “pending lock out fault” 2 alarm events
38
Shut Down Alarm Lockout
39
Shutdown Alarm Lockout
40
IntelligAIRE III DDM
41
IntelligAIRE III dEg System Set Up Mode
Setup Mode is disabled if the lockout bit is set in the configuration file. To enter, press and hold the Up/down key for 3 seconds. Team work
42
IntelligAIRE III Service Test Mode
Pt Pre Trip Down/select key 3 seconds Select key to scroll UP or Down to start test on/off to exit Pre-Trip test only available from DDM, not CanDIAG program Team work
43
IntelligAIRE III Service Test Mode Team work
44
IntelligAIRE III Pressure Readout Mode
SP1 Team work
45
IntelligAIRE III Temperature Readout Mode
rtS Rts – 1 second Actual temp. – 2 seconds Team work
46
IntelligAIRE III - - - Alarm Readout mode Active alarms only
Yellow-Check Red-Shut down Active alarms only Active alarms only Team work
47
Keypad Set Up & Diagnostics
48
Data Monitoring Files
49
Data Monitoring Files
50
Data Monitoring Files
51
Data Monitoring Files Use MMO Spreadsheet
52
Data Monitoring Files Demo Accessing Files Reading Files
Windows C drive Program files Thermo King CanDIAG Data Monitor MMO Highlight column A Data Text to column Delimited Next Check semi colon Finish
53
ClimaAire 1D
54
ClimaAire Controllers
ClimaAire 1D ClimaAire II
55
ClimaAire 1D
56
ClimaAire Set Up Kit
57
Overview of Controller Functions
„t1“ - Test mode 1 – basic test A/C unit function TEST MODE 1 allows operating the unit manually for charging or testing. „rt “ - Manual relay test „EL“ - evaporator low speed relay (EFRL) „En“ - evaporator medium speed relay (EFRM) „EH“ - evaporator high speed relay (EFRH) „CL“ - compressor clutch and condenser relay (CR) „bP“ - boost pump relay (BPR) „C0“ - modulating coolant valve (MCV)–low side output–for old ClimaAIRE I „C1“ - modulating coolant valve (MCV) – high side output „d0“ - damper output – low side output – for old ClimaAIRE I „d1“ - damper output – high side output „Pr “ - Set up of program number and firmware version reading „CA“ - Calibration of temperature sensors „SE“ - Set Up parameters „AL“ - Reading and clearing alarms „Hr“ - Reading hour meter
58
Alarm Indicators Red Alarm Symbol • Cycling of Clutch 05 Red alarm
Yellow Alarm Symbol • Cycling of Clutch 05 Red alarm • Long delay of HPCO and LPCO 06 Red alarm • Inverter Alarms – detail are described in SR10E Red alarm • RTS – Low value 07 Yellow alarm • RTS – High value 08 Yellow alarm • CTS – Low value 09 Yellow alarm • CTS – High value 10 Yellow alarm • ATS – Low value 11 Yellow alarm • ATS – High value 12 Yellow alarm
59
ClimaAire 1D Pocket Card
60
James Cole Western Region Service Manager – Bus HVAC