1 2017 CALACT Maintenance Forum
IntelligAire III & ClimaAire 1D Presented by: James Cole Western Region Service Manager – Bus HVAC

2 IntelligAire III Monitoring Screen

3 CanDiag Diagnostic Kit 204-1927
Laptop PC requires Windows® XP, Windows® 7

4 USB/CAN ADAPTERS New Version Old Version

5 Installing CanDiag Must have administrative rights and internet access to properly install Uninstall previous versions of CanDiag before installing version 1.6.0

6 CanDiag Icons

7 Diagnostics

8 Updating CanDiag Issue with CanDiag update link

9 CanDiag Firmware Version

10 IntelligAIRE III Updating & Firmware
Updating CanDiag & Firmware

11 IntelligAIRE III Updating CanDiag & Firmware

12 Updating CanDiag Issue with CanDiag update link
Contact James Cole at the Thermo King booth, or for temporary link until issue is corrected in program

13 CanDiag Setup

14 IntelligAire III Login
service irkolin

15 Custom Password 1) Left click on down arrow and hold
2) Drag cursor down to ‘change password’ 3) Release

16 Diagnostics

17 Module selection Main Module ID0 0 Main Module ID0 1 Main Module ID0 2

18 Module Screens Real Time Data Programmable Features & Test Modes Alarm
Codes Energized Outputs

19 IntelligAIRE III Configuration Files telligAIRE III

20 IntelligAIRE III Configuration Set Up telligAIRE III

21 IntelligAIRE III Configuration Set Up telligAIRE III

22 Flash Load/Configuration Files
IntelligAIRE III Can DIAG Flash Load/Configuration Files

23 IntelligAIRE III Configuration Files

24 DEMO

25 IntelligAIRE III IntelligAIRE III Sensor Calibration

26 Firmware Flash Load Cables

27 Bench Loading IntelligAire III Firmware

28 Bench Loading IntelligAire III
24v or 12v Power Supply

29 Warranty Procedure 41-9353 Main Module

30 EEPROM Backup

31 Service Bulletin 572-28 Firmware Revision 04.00.00

32 Firmware Cable Port Identification

33 Introduction to IntelligAIRE III
Flash Loading/Com Port Set Up Introduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN Start (lower left on desktop) Devices & Printers

34 Thermo King, Bus Service Manager
IntelligAIRE III Flash Loading/Com Port Set Up troduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN

35 Flashloading / Com Port Set Up
IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 P4 P2 P6

36 Flashloading / Com Port Set Up
IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 Cycle power to complete flashload P4 P2 P6

37 Shutdown Alarm Lockout
SB645-1 3 alarm events in 100 hour increments 17 possible shutdown codes Separate counter for each code Code 49 “pending lock out fault” 2 alarm events

38 Shut Down Alarm Lockout

39 Shutdown Alarm Lockout

40 IntelligAIRE III DDM

41 IntelligAIRE III dEg System Set Up Mode
Setup Mode is disabled if the lockout bit is set in the configuration file. To enter, press and hold the Up/down key for 3 seconds. Team work

42 IntelligAIRE III Service Test Mode
Pt Pre Trip Down/select key 3 seconds Select key to scroll UP or Down to start test on/off to exit Pre-Trip test only available from DDM, not CanDIAG program Team work

43 IntelligAIRE III Service Test Mode Team work

44 IntelligAIRE III Pressure Readout Mode
SP1 Team work

45 IntelligAIRE III Temperature Readout Mode
rtS Rts – 1 second Actual temp. – 2 seconds Team work

46 IntelligAIRE III - - - Alarm Readout mode Active alarms only
Yellow-Check Red-Shut down Active alarms only Active alarms only Team work

47 Keypad Set Up & Diagnostics

48 Data Monitoring Files

49 Data Monitoring Files

50 Data Monitoring Files

51 Data Monitoring Files Use MMO Spreadsheet

52 Data Monitoring Files Demo Accessing Files Reading Files
Windows C drive Program files Thermo King CanDIAG Data Monitor MMO Highlight column A Data Text to column Delimited Next Check semi colon Finish

53 ClimaAire 1D

54 ClimaAire Controllers
ClimaAire 1D ClimaAire II

55 ClimaAire 1D

56 ClimaAire Set Up Kit

57 Overview of Controller Functions
„t1“ - Test mode 1 – basic test A/C unit function TEST MODE 1 allows operating the unit manually for charging or testing. „rt “ - Manual relay test „EL“ - evaporator low speed relay (EFRL) „En“ - evaporator medium speed relay (EFRM) „EH“ - evaporator high speed relay (EFRH) „CL“ - compressor clutch and condenser relay (CR) „bP“ - boost pump relay (BPR) „C0“ - modulating coolant valve (MCV)–low side output–for old ClimaAIRE I „C1“ - modulating coolant valve (MCV) – high side output „d0“ - damper output – low side output – for old ClimaAIRE I „d1“ - damper output – high side output „Pr “ - Set up of program number and firmware version reading „CA“ - Calibration of temperature sensors „SE“ - Set Up parameters „AL“ - Reading and clearing alarms „Hr“ - Reading hour meter

58 Alarm Indicators Red Alarm Symbol • Cycling of Clutch 05 Red alarm
Yellow Alarm Symbol • Cycling of Clutch 05 Red alarm • Long delay of HPCO and LPCO 06 Red alarm • Inverter Alarms – detail are described in SR10E Red alarm • RTS – Low value 07 Yellow alarm • RTS – High value 08 Yellow alarm • CTS – Low value 09 Yellow alarm • CTS – High value 10 Yellow alarm • ATS – Low value 11 Yellow alarm • ATS – High value 12 Yellow alarm

59 ClimaAire 1D Pocket Card

60 James Cole Western Region Service Manager – Bus HVAC