Dozer: Sensors Calibration and Hydraulic Calibration
2
Pitch Sensor Location Mount the sensor on the blade
Allow the sensor to rotate 90 degrees for tilt calibration In this graphic it is positioned in the normal operating position
3
Pitch Sensor Calibration
Required if AS400 is permanently installed on the machine to measure blade pitch Park machine on level ground Make sure the left mast is vertical (if possible) in the forward/aft direction If it is not possible to make the left mast vertical, put the machine and blade in the normal working position Press “Calibrate” to zero the pitch sensor.
4
Pitch Sensor Calibration
5
Pitch Sensor Calibration
6
Valve Calibration - Basics
Allows smooth automatic control GCS900 monitors the valve movement and computes a response curve. Can be done with and without GPS /ATS Before starting the valve calibration you need to ensure that the machine measurements are entered into the CB430 The valve calibration should be done with warm oil and at normal operating revs.
7
Lift Calibration Must be in Manager mode
Setup / Installation Menu / Valve Calibration Select “Lift” A set of screens follow – perform the instructions
8
Calibration without GPS/ATS
The following screens appear if the GPS/ATS sensors are not detected or due to a low accuracy condition
9
Calibration without GPS/ATS
10
Calibration without GPS/ATS
11
Calibration without GPS/ATS
12
Calibration with GPS/ATS
Similar screens to previous method without the requirement to measure blade height differences (GPS/ATS does this for you!)
13
Calibration with GPS/ATS
14
Calibration with GPS/ATS
15
Calibration with GPS/ATS
16
Calibration with GPS/ATS
17
Calibration with GPS/ATS
18
Lift Calibration Place in Auto Press the Auto/Manual switch
System will then automatically move the blade and monitor the movement against the valve command
19
Lift Calibration
20
Lift Calibration
21
Lift Calibration
22
Tilt Calibration Process is similar to the lift calibration
Tilt Calibration requires the AS400 sensor to be rotated 90 degrees to measure the blade tilt
23
Tilt Calibration
24
Tilt Calibration
25
Tilt Calibration
26
Tilt Calibration
27
Tilt Calibration
28