1 Fan Coil Actuator FCA/S 1.x.x.2
Intelligent Building System ABB i-bus® KNX Fan Coil Actuator FCA/S 1.x.x.2 © ABB STOTZ-KONTAKT GmbH 2CDC N0201

2 Fan Coil Actuator family
Type description: Device F C A /S 1. x. x 1 Device version number 1 2 Device version number 2 Without manual operation With manual operation Valve drive, electrician (PWM, 3-point) Valve drive, analogue 1 fold (of fan) /S MDRC A Actuator C Coil F Fan FCA/S FCA/S Picture: 2CDC071001S0015, 2CDC071002S0015, 2CDC071003S0015, 2CDC071004S0015 FCA/S FCA/S © ABB STOTZ-KONTAKT GmbH 2CDC N0201

3 Fan Coil Actuator family
Overview of a 4-pipe system Fan Coil Units Hot water circulation loop Cool water circulation loop Picture: FanCoil-Units1 (F.R.) Boil and cold water supply © ABB STOTZ-KONTAKT GmbH 2CDC N0201

4 Fan Coil Actuator family
Design of a Fan Coil Unit Valves Fan Motor Switchbox with controller Drip tray Filter Heat exchanger Picture: Rohrsystem_allgemein2 (F.R.) © ABB STOTZ-KONTAKT GmbH 2CDC N0201

5 Fan Coil Actuator familiy
Pipe systems 4-pipe system 3-pipe system Picture: Rohrsysteme-alle3 (F.R.) 2-pipe system © ABB STOTZ-KONTAKT GmbH 2CDC N0201

6 Fan Coil Actuator family
Technical data Fan speed 3 (interlocked) Rated current 6 A Additional output 1 20 AX (16 AC load, AC3) or 16 A (10 AX) Inputs 3 (universal: temperature, contacts) Valve electrician (FCA/S , FCA/S ) or analogue (FCA/S , FCA/S ) Valve outputs signal voltage 2, analogue 0 … 10 V or 4, electrician (PWM, 3-point) Connection screw terminal Tightening torque max. 0.6 Nm Enclosure IP 20, EN Mounting on mounting rail 35 mm, DIN EN Width 6 module á 18 mm FCA/S FCA/S Pictures: 2CDC071001S0015, 2CDC071002S0015, 2CDC071003S0015, 2CDC071004S0015 FCA/S FCA/S © ABB STOTZ-KONTAKT GmbH 2CDC N0201

7 Fan Coil Actuator Connection schematic Label carrier
7 6 13 12 11 5 10 8 9 15 16 1 2 3 4 14 Example Label carrier Button Programming LED Programming (red) Bus connection terminal Inputs a, b, c Output A (valve e.g. HEATING) Output C (valve e.g. COOLING) Fan (3 x 6 A, 3 speed) Output H (16 A) Button/LED Manuelle operation (yellow) Button/LEDs output A (yellow) Button/LEDs output C (yellow) Button/LEDs fan speed (yellow) Button output H Buttons/LEDs inputs a, b, c (yellow) Display output H FCA/S Picture: 2CDC071004S0015, 2CDC072014F0012 © ABB STOTZ-KONTAKT GmbH 2CDC N0201

8 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. © Copyright [2015] ABB. All rights reserved. © ABB STOTZ-KONTAKT GmbH 2CDC N0201