Poseidon 4002 Rack monitoring.

Similar presentations


Presentation on theme: "Poseidon 4002 Rack monitoring."— Presentation transcript:

1 Poseidon 4002 Rack monitoring

2 Poseidon: Monitor & Control

3 IT environment threats in DC
Poseidon 4002 Poseidon 4001 Based on data from: 1) „Uptime Institute“ & „PROGNOSIS - Integrated Research“ for USA during 2) American Power Conversion 2006

4 Fast reaction required
For an average data center, the temperature rises from the usual 20°C to 30°C within minutes after A/C failure. Energy consumption (and thus A/C needs) of data center has risen by 48% from 1999 to

5 Poseidon 4002: Features Web: Built-in web server
Sensors: 4xRJ11 1-Wire UNI (max 12 probes) Inputs: 6 digital inputs (dry contacts) Outputs: 2 digital outputs (24VDC relays) GSM modem: External via RS-232 Mechanical: 1U (10" or 19" cabinet)

6 Sensors Four independent active sensor ports for 1-Wire UNI sensors.

7 Monitor your DC power Monitor -48V DC voltage of the batteries
Sensor 60V 1W-uni Galvanic isolated 1-Wire UNI sensor Monitor -48V DC voltage of the batteries Monitor DC current 0..80A

8 Feature 1-Wire UNI sensors
AC 230V 0..30A probe Meassure current in separated phase wire 8 analog 0..15V 6 DI for dry contact

9 Prevent these situations
Air Conditioning system failure Power system failures Short-term as well as long-term temperature issues Water leaks A/C units, pipeline, floods Security issues Controlled access to equipment

10 Poseidon 4002 Tset Poseidon 4002 Tset is recommended starting package for monitoring your 19” rack or cabinet. There are included most popular parts in one package Poseidon 4002 Tset: Poseidon 4002 Temp-1Wire 3m Temp-1Wire Rack19 L profile 19" size V Wall plug adaptor – EU HWg PDMS 8 (SW license) Big HWg paper box 2 Manual + CD

11 Typical Application Data centers Telecom rooms Network infrastructure
UPS monitoring Rack monitoring A/C monitoring and control

12 Poseidon 4002 Alarming SNMP SMS Email - SMTP Switch power
4 destinations GSM -> GSM SMS Internet -> GSM - SMTP Local relay output Switch power Remote relay over IP

13 Local relay output ON Local thermostat function, relay switched by sensor value.

14 GSM gateway function Poseidon 4002 with GSM modem is SMS gateway for sending SMS from other Poseidon units on local network. You need one GSM modem and one SIM card only per server room. Telephone number of Mr. Green (on this drawing) you define on Poseidon 4001 web page (source of green alert) SMS can be sent from Poseidon 3266, 4001, 4002 Communication is based on TCP/IP protocol (Soap) and SMS is postponed when GSM modem is busy.

15 Poseidon 4002: complete solution
Poseidon 4002 is a 19" 1U rack mount system for datacenter monitoring. The Poseidon solution monitors temperature, humidity, electricity supply, access to the room, detectors. Alerting works by , SNMP traps, SMS, output relays. Voltage -48V DC Temperature Smoke detector Current 30A AC Humidity Door opening detector Voltage 110/230 AC Control/detector Fan failure detector Energy meter Water leak detector Relay outputs GSM modem support (IP SMS GW function)

16 Summary Check the Poseidon 4002 online (online demo).
Download flyer or manual Order the Poseidon 4002 Tset for your first steps..