1
CatView Ltd Disposable View Catheter
Moshe Refael CEO
2
Contents The technology platform The product Development roadmap
Regulatory pathway Investment sought.
3
Key Personal The Entrepreneurs: Moshe Refael – CEO
Prof. Steve Lipson. Optics, Technion Haifa Prof. Ariel Roguin. MD, Rambam Hospital Haifa Dr. Yaron Hefetz Optics, GE Haifa Avinoam Baruch, Mech. Eng.
4
Current Endoscopy Methods
Regular metal pipe line guides NO Viewing guides available on the market (not created.. yet)
5
The problem Part 1 There are 4 major problems:
Light scattering by blood cells. Optical absorption by plasma To provide an image using a few optical fibers. To introduce a stent in the right position
6
The solution The planned catheter guide To have a channel for introducing a clear liquid in front of the camera, in order to clear the red blood cells and improve the transparency
7
The solution To provide a viewing guide which allows placement of the stent in the optimum position.
8
The angiographic beauty of stenting
The regular procedure The angiographic beauty of stenting
9
Stent Placement Guide Balloon Stent
10
CatView Product The Solution:
* To develop a guide with real-time visual observation capabilities, with or without a working channel. * Following this, surgeons will be able to conduct their guides in real time as in gastroscopy.
11
The Technology Platform
The project will create a platform for minimal invasive treatment such as: Heart Catheterized procedures Anaesthetization. Lungs – Bronchoscopy. Urology – in-vivo observation and biopsy Brain blood vessel inspection and treatment
12
CatView’s Catheter Features
Camera creating 80 pixel image Optical fiber bundle with 100 fibers, outer diameter 250µm, for illumination and imaging Nozzle to introduce a clear physiological fluid in front of the imaging lens Navigation drive Total 325± 25 µm diameter
13
The calculation is as follows:
Optic Calculation Requirements The calculation is as follows: The required resolution according to the MD’s is 500µm The cross-sectional area of the artery is: 4=15.5mm2 Image is projected onto 100 optical fibers Four fibers used for illumination
14
Fluid injection Annular space around the fiber optic to transport clear fluid to the imaging region Pump to introduce the fluid
15
Product Overview The Diastolic Head The Intracorpus probe Proximate
Joystick Light source Liquid Pump Proximate Interface USB Interface
16
Front end- Probe Lens Liquid spraying nozzles Navigating head
17
Probe’s Cross\cut section
Fiber Optic Bundle Vacuum & pressure tubular + SPRED LIQUIDS
18
Cross Cut section 2
19
Navigator system
20
Probe’s cross section Fiber Optic bundle Vacuum liquid nozzle
Transparent liquid pipe Fiber Optic bundle Vacuum liquid nozzle
21
Proximate Unit Liquids pipe Optic fiber Lens Beam Splitter
Reflected Image Light source CMOS Camera Camera Board
22
Activities Technological: Detailed design study. Management:
Breadboard system Testing Management: Market search & Business Plan Patent search & PCT filing. Helsinki Approval Marketing (for raising money) Preliminary experiments on animals Regulatory strategy FDA path (Human experiments – 3rd year) Technical writing
23
Gantt R &D Activities 2016 2017 2018 Characterizing Optical design
Mechanical design Purchasing* Building of first model Lab test first round Re-design after test improvement Business Plan Strategic regulation Helsinky certification Animal trails FDA approval Human trails Marketing** Money In 500$ K $1.5M $ 4M * Fibers, Camera board, Beam splitter, pump, Joystick ** marketing = Raising money