PAD-MAD requirements for Access in ISOLDE target area

Similar presentations


Presentation on theme: "PAD-MAD requirements for Access in ISOLDE target area"— Presentation transcript:

1 PAD-MAD requirements for Access in ISOLDE target area
Stefano Marzari

2 Project 24.5.2012: Storage MEDICIS PAD-MAD Doors Exchange point
Vehicle garage Isolde Primary area Limited stay area Controlled area Laboratories Projected new buildings 2 3 5 1 4 1 shielded door 2 ventilation door 3 storage door (primary area side) 4 storage door (hot cell side) 5 MEDICIS door > 100 mSv/h 0.1…2 mSv/h < 25 µSv/h < 2.5 µSv/h

3 Simulation with Isolde proton beam parameters on HRS target.
>100 mSv Fluka from Leonel : Simulation with Isolde proton beam parameters on HRS target. Without contribution of: Storage of 100 activated targets (0.25 to 3 years decay) -Medicis bunker with 1 Sv at 10 cm ~150 µSv ~150 µSv MEDICIS Labo ~10 µSv

4 Access cases study: Case 1: proton ON Case 2: proton ON: target from storage to Hot cell with remote handling vehicle Case 3: proton STOP: hot/new target to/from exchange point (KUKA robot work) Case 4: proton STOP: hot target from exchange point to storage Case 5: proton STOP: New target to exchange point Case 6: proton STOP: Hot target autopsy Case 7: proton STOP: Hot target to MEDICIS Case 8: proton STOP: target from Storage to MEDICIS and vice-versa Case 9: proton STOP: Target area inspection with remote handling vehicle Case 10: proton STOP: short Shut down Case 11: proton STOP: long Shut down

5 Case 1: proton ON No access Limited access

6 Case 2: proton ON: target from storage to Hot cell with remote handling vehicle
No access Limited access

7 Case 3: proton STOP: hot/new target to/from exchange point (KUKA robot work)
No access Limited access

8 Case 4: proton STOP: hot target from exchange point to storage (and vice-versa)
No access Limited access 3 Sequences: max.10 minutes Move the vehicle in front of door 3 Open door 3 Pass the door with vehicle Take target on exchange point Close door 3 Put the target in the storage => Patrol in the primary zone

9 Case 5: proton STOP: New target to exchange point (normal access through PAD-MAD)
No access Limited access

10 Case 6: proton STOP: Hot target autopsy
No access Limited access 3 4 Sequences: max.20 minutes Move the vehicle in front of door 3 Open door 3 Pass the door 3 with vehicle Take target on exchange point Close door 3 Open door 4 Pass door 4 Close door 4 Put the target in the hot cell SAS Pass the door 4 with vehicle => Patrol in the primary zone

11 Case 7: proton STOP: Hot target to MEDICIS
No access Limited access 3 5 Sequences: max.15 minutes Move the vehicle in front of door 3 Open door 3 Pass the door 3 with vehicle Take target on exchange point Close door 3 Open door 5 Put target on MEDICIS Close door 5 => Patrol in the primary zone

12 Case 8: proton STOP or proton ON : target from Storage to MEDICIS (and vice-versa)
No access Limited access

13 Case 9: proton STOP: Target area inspection with remote handling vehicle
No access Limited access

14 Case 10: proton STOP: short Shut down
No access Limited access After access: => Patrol in the primary zone

15 Case 11: proton STOP: long Shut down
No access Limited access After access: => Patrol in the primary zone