Download presentation
Presentation is loading. Please wait.
1
(University of Sofia “St. Kliment Ohridski”)
The CMS muon system Borislav Pavlov (University of Sofia “St. Kliment Ohridski”) for the CMS Collaboration haha
2
Introduction Introduction CMS Muon System DT CSC RPC Moun Trigger
Summary haha 6th BPU Conference B. Pavlov
3
CMS: design & construction
Muon System haha 6th BPU Conference B. Pavlov
4
System Conditions & Requirements
Muon identification Muon Trigger Unambiguous BX identification Trigger single and multimuon with well defined pt thresholds few GeV to 100 GeV Muon momentum measurement Charge assignment correct to 99% confidence level up to 7 TeV Momentum resolution Stand alone dpt/pt = % at pt = 10 GeV dpt/pt = % at pt = 1 TeV Global dpt/pt = % at pt = 10 GeV dpt/pt = % at pt = 1 TeV Barel h < 1.3 Particle rates < 10 Hz/cm2 Low Magnetic field Endcap < h < 2.4 Particle rates Hz/cm2 Magnetic field Uniform axial > 3 T in ME1/1 Highly non-uniform radial field Up to 1 T in ME1/2 haha 6th BPU Conference B. Pavlov
5
CMS Muon System Reduced RE system MB4 |h| < 1.6 MB3 MB2 MB1 ME3
¼ longitudinal slice Reduced RE system |h| < 1.6 MB1 MB2 MB3 MB4 1.6 ME3 ME4/1 restored ME2 ME1 haha 6th BPU Conference B. Pavlov
6
Cathode Strip Chambers - CSC Resistive Plate Chambers - RPC
Requirements Spatial resolution (F) (per station) 75 mm ME1/1 and ME1/2 150 mm for the others (At the trigger level < 2mm) Correct BX identification > 92% per chamber ( 99% global) Trigger Track Efficiency >99 % per chamber Resolution (per station) Position RF : mm Z : mm Angle: 1 mrad BX identification Efficiency >98% per station Drift Tubes - DT Cathode Strip Chambers - CSC BARREL ENDCAP Resistive Plate Chambers - RPC (Dedicated Trigger Detector) Good timing : Resolution < 3ns (RMS), 98% within a 20ns window Good Rate capability Low cluster size High efficiency > 90% per chamber ( 95% global) rF resolution ~ 1cm haha 6th BPU Conference B. Pavlov
7
(Gas tightness, HV, Front End)
Drift Tube Chambers 42mm 13 mm 4 Layers = 1 Superlayer (SL) Mylar Electrode Strip Cathode Al Strips Wire Independent Subunit (Gas tightness, HV, Front End) GAS: Ar/CO2 (85/15) HV: Wires V Strips V I-beams V F SL q SL Honeycomb Tmax: ns Single Wire mm F Drift Velocity : ~ 55mm/ns Resolution : < 300 mm mm q haha 6th BPU Conference B. Pavlov
8
DT Local trigger - Bunch Track Identifier (BTI)
Based on meantime technique MT is independent on the track angle and position MT1 = 0.5 * (T1 + T3) + T2 MT2 = 0.5 * (T2 + T4) + T3 Signals are shifted in registers BTI looks for coincidence every clock period hits in ≥ 3 planes At a time T=Tmax after muon crossing the drift times are aligned i.e. the hits form an image of the muon track Allows effective bunch crossing identification haha 6th BPU Conference B. Pavlov
9
The Barrel Muon system comprises 250 chambers
Barrel Muon DT 1 4 2 3 5 6 7 8 9 10 11 12 60 MB1 3SL 2 RPC ~2.0 x 2.54 m kg 60 MB2 3SL 2 RPC ~2.5 x 2.54 m kg 60 MB3 3SL 1 RPC ~3.0 x 2.54 m kg 40 MB4 2SL 1 RPC ~4.2 x 2.54 m kg 10 MB1 2SL 1 RPC 10 MB2 2SL 1 RPC 10 MB3 2SL 1 RPC The Barrel Muon system comprises 250 chambers In 7 flavors for 5 wheels Total 1700 m2 haha 6th BPU Conference B. Pavlov
10
DT Production Sites Production sites CIEMAT AACHEN TORINO LEGNARO haha
6th BPU Conference B. Pavlov
11
Cosmic Event in a CMS sector
haha 6th BPU Conference B. Pavlov
12
Magnetic field = 1T Cosmic muon trajectory in the barrel DTs
haha 6th BPU Conference B. Pavlov
13
Cathode Strip Chambers (CSC)
Gas:Ar(40%) + CO2 (50%) + CF4(10%) Gas gap 9.5mm Wire spacing ~3mm HV wires ~ 3.6 kV Trapezoidal Chambers (100 or 200 in F), 6 layers Radial cathode strips – measure F ( mm) Wires orthogonal to strips Precise timing measurement (BX) - ~4.5 ns Coarse measurement of the radial position (16-54 mm) haha 6th BPU Conference B. Pavlov
14
CSC Outer section of 4’th station staged 6 planes per chamber
468 chambers 6000 m2 sensitive area 2 Million wires 220 K cathode channels 1 chamber ~ 1000 readout chanels ME1/1 –special design Inserted in endcap Calorimeter support haha 6th BPU Conference B. Pavlov
15
CSC production sites Dubna PNPI – 114 assembled IHEP – 148 assembled
Chamber with on-board electronics haha Dubna FNAL – 148 assembled Dubna – 72 assembled 6th BPU Conference B. Pavlov
16
Final Testing before installation at SX5
ISR FAST Site Final Testing before installation at SX5 haha 6th BPU Conference B. Pavlov
17
CSCs on YE+1 and YE-1 YE+1 YE-1 14 June, 2006 haha B. Pavlov
6th BPU Conference B. Pavlov
18
Chamber commissioning at SX5
using test pulses and cosmic rays Cosmic Ray First particles detected by installed “CMS” subsystem!! haha 6th BPU Conference B. Pavlov
19
Resistive Plate Chambers
Resistive Plates – bakelite with bulk resistivity (2 ± 1).1010Ωcm Gas gap (2mm ± 20μm wide) Gas mixture, containing 96% C2H2F4(Freon), 3,5 % isobutan, SF6 – 0,5 % Graphite electrodes with resistivity 300 kΩ / cm Insulating PET film (0.3 mm thick) Detecting copper strips 40μm thick,2–4 cm wide and 1250 mm long Spacers (cylinders with diameter 10 mm and height 2mm) Copper shielding Linseed oil treatment haha 6th BPU Conference B. Pavlov
20
RPC - Principle of Action
haha 6th BPU Conference B. Pavlov
21
CMS RPC Fast detectors for the first level trigger of the experiment
Considerably good space resolution Able to work in areas with background ~ 10 3 Hz/cm 2 Price – as low as possible Requirements Time resolution ≤ 1.8 ns (98 % within 20 ns) Efficiency > 95 % Rate capability ≤ 1kHz/cm2 Average cluster size < 2 strips Number of streamers < 10% Operation plateau > 300V Power consumption 2-3 W/m2 Operational voltage 8.5 –10 kV haha 6th BPU Conference B. Pavlov
22
Main Barrel RPC Types Length: 2.455 m Width: 1.5, 2.0 , 2.5 m
Pitch: 40.8, 40.6, 41.0 mm # Strips for Gap: 48, 36, 48, 60 Left Right RB4 Width: 1.48 m Pitch: 34.8 mm # Strips for Gap: 42 Left Right RB3 Width: 1.5, 2.0 , 2.5 m Pitch: 27.3, 29.3 mm # Strips for Gap: 84, 90 Out RB2 In Width: 1.5, 2.0 , 2.5 m Pitch: 22.7, 24.3 mm # Strips for Gap: 84, 90 Out RB1 In haha 6th BPU Conference B. Pavlov
23
Barrel RPC Production ISR Pavia Sofia GT Bari GT HT RB1 in Pavia
Chambers production and quality certification involve several steps. Pavia Sofia GT Bari GT Single gap Double gap HT Chamber assembling Sites Chamber test Sites RB1 in Pavia RB2 & RB4 in Bari RB3 in Sofia (& Bari) 120 RB1 at HT 240 RB2 and RB4 at GT 120 RB3 in Sofia (& Bari) haha 6th BPU Conference B. Pavlov
24
RPC Production Sites Bari Sofia Pavia haha B. Pavlov
6th BPU Conference B. Pavlov
25
ISR RPC storage and test area
RPC tests at ISR ISR RPC storage and test area haha 6th BPU Conference B. Pavlov
26
Installation of DT and RPC
At ISR Coupling RPC to DT Fast test Transportation to SX5( CMS surface hall) At SX5 Installation in the CMS Detector Started in June haha 6th BPU Conference B. Pavlov
27
Cosmic event in the RPCs
haha 6th BPU Conference B. Pavlov
28
Endcap RPC CERN Project Co-ordination ISR Assembly Station
China Korea Pakistan Gap production Front-end electronics CERN Project Co-ordination ISR Assembly Station haha 6th BPU Conference B. Pavlov
29
RPC Production Sites Korea Pakistan ISR Lab Test of first chambers
haha Test of first chambers 6th BPU Conference B. Pavlov
30
Muon Trigger haha 6th BPU Conference B. Pavlov
31
Magnet test and Cosmic runs are going now
Summary CMS Muon System – big international project - 3 Continents Magnet test and Cosmic runs are going now DT Chambers DT production ended (266 out of 250) Delivered to CERN - 262 Installed CSC Chambers Production finished (496 out of 468 CSCs) Delivered to CERN – 495 Installed - 432 RPC Chambers 460 (out of 480) barrel RPCs assembled. End of production - December. Delivered to CERN – 380 Installed - 278 Endcap RPC – YE+1 and YE+2 installed Endcap RPC - YE+3 and YE-1 will be installed until the end of the year haha 6th BPU Conference B. Pavlov
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.