Introduction Intelligent Manager For VRF System
2
01 / Main Features of IMM 02 / System Overview 03 / Functions 04 / Highlights 05 / Comparison with other players
3
IMM, connects the air conditioners to the INTERNET
1)Main Features of IMM IMM, connects the air conditioners to the INTERNET
4
1)Main Features of IMM SYSTEM STRUCTURE Router PC-IMM M-interface
Air-Conditioner System
5
2)System Overview PC, Laptop, Pad MAX. 4 M-interfaces in a IMM system
Maximum: 1024 indoor units 256 outdoor units 64 refrigerant system
6
2)System Overview
7
2)System Overview M-INTERFACE gateway port side view
8
2)System Overview Auto topology: Max. 16* ODUs, 256 IDUs
Up to maximum 4* refrigerant systems can be connected to one M-interface. 4 ports for XYE 4 ports for K1K2E XYE K1K2E XYE K1K2E XYE K1K2E XYE K1K2E
9
2)System Overview Manual topology: Max. 64* ODUs, 256 IDUs
Up to maximum 16* refrigerant systems can be connected to one M-interface. 4 ports for XYE 4 ports for K1K2E One group port Max 64 IDUS Max 4 systems, 16ODUS XYE K1K2E XYE K1K2E XYE K1K2E XYE K1K2E
10
2)System Overview Local LAN access
11
2)System Overview Remote WAN access through VPN connection
12
2)System Overview VPN control Access Long distance PC (IMM)
Through VPN IP/Ethernet Firewall Router Local PC (IMM) A/C Units
13
Energy saving management
3)Functions Web Access Function Device monitoring Schedule Control Energy saving management Electricity Charge Distribution
14
3)Functions Web Access Function
PC, laptop, pad or a smart phone can be used like a remote controller. Via the Internet using a Web browser such as IE, Firefox, Safari or Chrome Up to 4 simultaneous connections IP address of the M-interface User ID and PW
15
3)Functions Device monitoring
Click & Operate a user-friendly interface allows even non-experts to perform building systems management easily. Check the status of all of the IDUs/ODUs/M-interfaces. Control single/Multi IDUs.
16
3)Functions User Friendly Indoor Unit Power off Cooling Heating
Air-inlet Error Lock Offline Schedule Outdoor Unit Power off Cooling Heating Error Offline M-interface Online Offline
17
3)Functions Schedule Control 4 time sections for one schedule
Several schedule can set in each day for each single unit or group. Automatically controls facility start/stop, switch the operating mode, setting temperatures and enable/disable the remote control according to the present time schedule. 3)Functions Schedule Control
18
Prevent to forget turn off
3)Functions Schedule Control Example: One Schedule pattern (Save Power) Time AM 8:30 OFF ON Auto 27 ℃ South Hall Conference 26 ℃ 25 ℃ North Hall Office 28 ℃ Working Time PM6:00 Save Energy Monday to Friday (Midea CAC Office) Over Time Working PM9:00 12:00 Prevent to forget turn off PM1:30 Lunch
19
3)Functions Energy saving management Selection Specifications
Cooling temp. limit Set the lowest limit of cooling temp., and limit the remote controller control Heating temp. limit Set the highest limit of heating temp., On and off unit limit Limit the indoor unit on and off operations of the remote controller Mode limit Limit the unit cooling, heating mode operations Fan speed display Limit the fan speed control by the remote controller Swinging limit Limit the swinging control by the Remote controller limit Limit the air conditioner operations by the remote controller Energy saving management
20
Midea Patented technology
3)Functions Electricity Charge Distribution Electricity charge apportionment can be done easily when the power consumed , its very convenient to bill for power charges of the tenants in a commercial building, offices in a rental building, or rooms in a hotel. The IMM will record the Energy used by each ODU Capacity demand of Each IDU Midea Patented technology 24 Hrs Electricity charges by tenant are calculated by IMM Hourly power consumption of each IDU report to IMM Energy will be apportioned by the ODU to each IDU
21
3)Functions Safeguard Mechanisms for Electricity Charge Distribution in case of power loss The Indoor capacity demand is calculated according to the set. Temp. /room. Temp./rated HP/running mode, etc. Every hour, the M-interface calculates the Electricity charges of each tenant. And automatically send to IMM as well. In case of 20% of IDUs power fails, ODU will stop for protection. Even if the communication between ODU and Power Ammeter fails , the power consumption record still exists. Even if the power of IMM fails, the record still exists. The idle machines and public area A/C will be distributed to all the tenants.
22
3)Functions Note: Connecting a power meter allows the charges to be calculated for a variety of usage patterns: such as charges for the power used on a per day basis or just the charges for the power used by the outdoor unit or the charges for the tenants.. Digital Power Ammeter (DTSXXX)
23
4)Highlights Warning Message Powerful data backup
Visual Navigation Warning Message Powerful data backup User Security control Multiple Languages
24
4)Highlight Visual Navigation
Allow to import Building drawing or picture(jpg, gif, png,etc.), to directly control the corresponding IDU on the ‘map’.
25
4)Highlight Visual Navigation
User can put the units in a exact places of the picture Make the operation management more convenient Visual Navigation
26
4)Highlight Warning Message
If error occurs, it will be notified with warning message. The system is able to send error messages to designated mobile phone number automatically via public phone lines.(* optional) * It is necessary to purchase an additional piece of equipment named ‘SMS Modem’ from Midea
27
4)Highlight Warning Message This message also can be sent via Email.
The system is able to send error messages to designated address automatically via Midea’s server.(* optional) * It is necessary to customized this function when you purchase IMM software. And the will come from @midea.com.cn
28
4)Highlight Powerful data backup
Double data backup (Inner hardware and Hard Disk Drive) In case of power failure or system crash, the M-interface will automatically backup the data to the equipment. 1. Indoor/outdoor unit name 2. Power distribution data 3. Operation history (by IMM) 4. IMM power On/Off history 5. System configuration 6. Others And the IMM software will also store operational data to the HDD of PC every hour. Note: A backup for power failure UPS is necessary to be field supplied.
29
4)Highlight User Security control
ID and password, user, administrator and service person can be registered separately. Administrators have an authority to set accessible levels IMM functions on users. Service person have even more special authority.
30
4)Highlight 9 different languages: Multiple Languages English
Russian French German Italian Spanish Simple Chinese Korean Polish
31
5) Comparison with other players
Midea D Brand H Brand G Brand Appearance of Interface Design with different color and icons. Industrialized design, simple icon and appearance. Use numbers to distinguish different units. Convenient Operation Friendly operation, allows users to select any combination of units with mouse, even in different systems Allows users to select the units at special status, for example, choosing all the cooling units. Allows users to select a single unit or some group of units Function Description Energy saving management(Mode, fan-speed, cooling/heating temperature, etc.) No energy saving management Electricity charge distribution: Patterned technology Allows more than one clients to login at the same time Allows one main client and two vise clients to use at the same time Allows one client
32
5) Comparison with other players
Midea D Brand H Brand G Brand Gateway The gateway is able to save and back-up the datas, even if the computer and gateway fail, data recovery is possible, provide strong safety for data. The gateway is able to save the data before uploading to PC, after uploading, no back-up after uploading The gateway is not able to save data Content of Report Electricity charge distribution table Operating status of all the unis Indication of the electricity meter of outdoor units Operating record System log
33
Climate Solutions for Green Environments!