Download presentation
Presentation is loading. Please wait.
1
Sampling Point from flare location
Table 7. Mean air quality and meteorological parameters for gas flaring plant locations P, Q and R Sampling Point from flare location 20m 35m 50m 75m 100m 500m 700m DPR Limits FEPA Limits S/N Parameters Equipment Value 1 SO2 (µg/m3) Gas Detector 26.90 21.67 27.90 23.12 17.07 <0.01 26-260 2 NO2(µg/m3) 42.89 39.05 32.51 33.07 25.10 0.012 150 75-113 3 H2S (µg/m3) 19.48 20.78 17.03 11.08 14.55 0.21 -- 4 CO (mg/m3) 18.80 19.08 10.47 11.40 6.12 1.01 10 5 VOC (µg/m3) 8.03 7.54 8.02 3.17 1.06 0.08 - 160 6 CH4 (µg/m3) 45.90 38.11 40.98 27.09 22.76 1.74 7 Ambient Temperature (oC) Thermometer 42.80 40.17 35.80 30.10 31.60 29.80 31.30 8 SPM (µg/m3) Laser part. Count 8.12 4.09 4.74 1.96 1.18 60-90 9 Relative Humidity (%) Humidity meter 61.5 64.5 61.8 64.90 63.20 62.10 62.30 Smoke Density (Ringleman) BS 2742:1969 2.0 1.0 11 Atmospheric Pressure (kPa) Digital Barometer 100.9 12 Heat (Flare) Radiation (W/m2) Radiometer 4710 4033 3061 2458 1369 582 173 6310 13 Wind Speed (m/s) Anemometer 0.60 1.50 1.20 0.70 0.80 1.10 14 Wind Direction NE NW Uyigue L et al. Physicochemical Analysis of Gas Flaring Impact on the Environment of Host Communities in the Niger-delta. Journal of Environment Pollution and Human Health, 2017, Vol. 5, No. 1, doi: /jephh-5-1-4 © The Author(s) Published by Science and Education Publishing.
Similar presentations