1 Use of Pythagorean Theorem in #9 Single Implant Case
Guide Right ™ Use of Pythagorean Theorem in #9 Single Implant Case 3 mm X 30 mm guide post 3 mm guide sleeve 3 mm X 1.5 mm offset guide post 3 mm open guide sleeve Pythagorean Theorem ► Cosine software analysis Invivo5 Anatomage Featuring: LINEAR CORRECTIONS DIAGNOSTIC Guide SURGICAL Guide BEL

2 Fabrication of DIAGNOSTIC guide

3 Line marked on teeth to position original axis
facial view Line marked on teeth to position original axis for initial 3/32” drill mm & 3 mm guide post.

4 3 mm X 30 mm guide post in 3/32” hole

5 3 mm guide sleeve placed on the 3 mm guide post
and cast lubricated with petroleum jelly

6 Initial layer of Triad® Gel added to the guide sleeve cleats
and cured to stabilize the guide sleeve.

7 showing the 3 mm guide sleeve attached to the cured acrylic
DIAGNOSTIC Guide showing the 3 mm guide sleeve attached to the cured acrylic ready to be placed for cone beam X-ray.

8 Additional and final layer of Triad® Gel
extended to lingual and incisal surfaces of adjacent teeth

9 PRE-OPERATIVE Software Evaluation Invivo5 Anatomage

10 INITIAL EVALUATION axial plane cross sectional plane · buccal-lingual
of DIAGNOSTIC guide sleeve position axial plane cross sectional plane · buccal-lingual # 9 Invivo5 Anatomage Invivo5 Anatomage tangential plane · mesial-distal 3D volume

11 Axial Plane Greater accuracy in implant placement is achieved when the line representing the bucco-lingual plane is set at 90° to the buccal surface of the arch. Yellow line passing through the axis of the implant creates the view seen in the cross sectional view (next slide). Dragging the yellow line in the software will change the cross sectional view as the line rotates about the axis of the implant. The markings on the concentric circles are 5 mm apart allowing measurements to be calculated. virtual implant Invivo5 Anatomage # 9

12 preferred implant placement
# 9 cross sectional plane · bucco-lingual Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual axial plane cross sectional plane · bucco-lingual Invivo5 Anatomage Invivo5 Anatomage tangential plane · mesio-distal 3D Volume

13 LINEAR CORRECTION # 9 Illustrating preferred implant placement position (bucco-lingual) The virtual implant is moved parallel & facial 1.3 mm to the location of the DIAGNOSTIC guide sleeve. Yellow line passing through the axis of the implant. virtual implant actual guide sleeve 5 mm grid intervals to allow measurements to be calculated. Invivo5 Anatomage cross sectional view.

14 LINEAR CORRECTION # 9 Illustrating preferred implant placement position (mesio-distal) Illustrating the preferred implant placement in the tangential view The center of the virtual implant is located 1 mm mesial to the center of the DIAGNOSTIC guide sleeve. virtual implant 5 mm grid intervals to allow measurements to be calculated. actual guide sleeve Invivo5 Anatomage tangential view

15 preferred implant placement
tangential plane · mesio-distal Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual axial plane cross sectional plane · bucco-lingual Invivo5 Anatomage Invivo5 Anatomage tangential plane · mesio-distal 3D Volume

16 Review of Pre-op Corrections
#9 LINEAR CORRECTION 1.5 mm offset guide post rotated 45º toward the mesial & facial. Cosine is applied to determine correction data. * see next 3 slide

17 Pythagorean Theorem COSINE Calculations for Guide Right™ Guides
The cosine of 45° is recommended for Guide Right corrections BECAUSE rotating the offset guide post half way between 2 adjacent planes (90° apart) is 45°.

18 Correction based on the calculations from the Pythagorean Theorem
To move the position of the guide sleeve 1 mm both mesially & buccally: ► use a 1.5 mm offset guide post ► and rotate the offset guide post 45º to a mesio-buccal position. Cosine of 45° X 1.5 mm = X 1.5 mm = 1.06 mm

19 A= cosine of 45º X 1.5 (0.707 X 1.5 mm = 1.06 mm mesio-facial
facial mm A = 1.5 mm 45° mesial mm mesio-facial 45° Bell case mesio-facial guide post center

20 A= cosine of 45º X 1.5 (0.707 X 1.5 mm = 1.06 mm facial 1.0
45° mesial mm mesio-facial

21 Fabrication of SURGICAL guide

22 1.5 mm offset guide post rotated 45º toward the mesial & facial.
palatal view 1.5 mm offset guide post rotated 45º toward the mesial & facial.

23 Initial application of Triad® Gel
to capture the cleats on the open guide sleeve to form the SURGICAL guide.

24 Additional Triad® Gel added to adjacent teeth

25 Final SURGICAL guide

26 SURGICAL guide (facial view)

27 POST-operative RESULTS
Software Analysis Invivo5 Anatomage

28 # 9 POST-OP RESULTS showing actual implant placement. axial plane
cross sectional plane · bucco-lingual Invivo5 Anatomage tangential plane · mesio-distal 3D Volume

29 Axial Plane # 9 POST-OP results Invivo5
Greater accuracy in implant placement is achieved when the line representing the bucco-lingual plane is set at 90° to the buccal surface of the arch. Yellow line passing through the axis of the implant creates the view seen in the cross sectional view (next slide). virtual implant The markings on the concentric circles are 5 mm apart allowing measurements to be calculated. Dragging the yellow line in the software will change the cross sectional view as the line rotates about the axis of the implant. Invivo5 Anatomage

30 Cross Section (bucco-lingual)
# 9 POST-OP results Yellow line passing through the axis of the implant. virtual implant superimposed over actual implant 5 mm grid intervals to allow measurements to be calculated. actual open guide sleeve Invivo5 Anatomage Only one wall of open guide sleeve is visible.

31 Tangential (mesio-distal)
# 9 POST-OP result virtual implant superimposed over actual implant. 5 mm grid intervals to allow measurements to be calculated. actual guide sleeve Invivo5 Anatomage

32 Guide Right™ Products shown in this case
1 - 3/32” drill mm X 30 mm Guide Post 1- 3 mm Guide Sleeve 1 - 3 mm x 1.5 mm Offset Magnetic Guide Post 1 - 3 mm Open Guide Sleeve Guide Post Bending Tool Triad® Gel

33 A System of Components for the fabrication and correction of diagnostic & surgical templates in one or two dimensions In-office or lab fabrication Evaluate with 2D & 3D imaging Allows linear and angular correction Enables precision implant placement Cost effective

34 Guide Right™ Surgical Guide System
DéPlaque Guide Right™ Surgical Guide System fabricate ▪ evaluate ▪ correct ▪ verify ▪ place Start With Precision. Place With Confidence.™