Download presentation
Presentation is loading. Please wait.
1
Design Aides for Concrete Masonry Members
EPSCoR Research Fellowship Angela Jones Jennifer Tanner, PhD University of Wyoming
2
Origin of Masonry Old building material Random rubble masonry
3
Brick Brick making is estimated to be 10,000 to 12,000 years old.
4
Fired Brick
5
Grouted Brick Masonry Bearing wall construction
Large scale use seen in The late 1800s Monadnock Building, Chicago
6
Concrete Masonry Units
Process of constructing CMU began in 1882. First CMU Cast were 30” units cast on site.
7
Concrete Masonry Units
Mechanical Vibration Zero slump concrete Current production process highly automated
8
Design Provisions Uniform Building Code BOCA National Building Code
(Building Officials and Code Administrators International) The Standard Building
9
International Building Code
Emerged in 1994 Phase out previous codes By 2000 Broad-based principles
10
Masonry Code Masonry Standards Joint Committee Code
Final review of the first edition approved in 1988. MSJC Code is revised on a three year cycle.
11
Goals Evaluate peak stress conditions Allowable Stress Design
Strength Design
12
Allowable Stress Design
Older analysis Widely used Elastic Behavior External Loads
13
Strength Design Newer analysis ACI 530 code (2002) More complex
Variability in materials
14
Strength Design Newer analysis Limit states
15
Strength Design Newer analysis Probability of failure
Statistical Analysis
16
Analysis Interaction Diagrams Single Wythe Masonry Walls
#4, #5, #6 Reinforcement 6”, 8”, 10”, and 12” walls 12” and 24” reinforcement spacing Solid and Partially Grouted Walls
17
Analysis Interaction Diagrams Axial Capacity Flexural Capacity
Balance Point Tension Controlled Compression Controlled Flexural Capacity Column Analysis T-Beam Analysis I-Beam Analysis
18
Simple Analysis effective width, bf Fb C hf kd bw h T = As*fs
Steel Reinforcement 0 < kd < 1.25” Allowable Stress Design
19
T-Beam Analysis effective width, bf Fb F1 F2 hf kd F3 bw h
Steel Reinforcement 1.25” < kd < h-hf Allowable Stress Design
20
I-Beam Analysis effective width, bf Fb F1 hf F2 F3 F4 bw kd h F5
Steel Reinforcement F6 F7 h-hf < kd < h Allowable Stress Design
21
I-Beam Analysis effective width, bf Fb F1 hf F2 F3 F4 bw h F5
Steel Reinforcement kd F6 F7 F8 h < kd Allowable Stress Design
22
Simple Analysis effective width, bf fb hf a C bw T = As*fs h
Steel Reinforcement a = 0.8*c Strength Design
23
T-Beam Analysis effective width, bf fb hf a C bw T = As*fs h
Steel Reinforcement a = 0.8*c Strength Design
24
Face Shell Dimensions ASTM C90 Minimum Face shell thickness:
6” block = Minimum 1” Face Shell 8” block = Minimum 1 ½ “ Face Shell 10” block = Minimum 1 ½ “ Face Shell 12” block = Minimum 1 ½ “ Face Shell
25
Results Axial Capacity Flexural Capacity
26
ASD 24 Inch Spacing
27
ASD 48 Inch Spacing
28
SD 24 Inch Spacing
29
SD 48 Inch Spacing
30
Conclusion Below The Balance Point Above The Balance Point
Solid grouted equations are sufficient. Above The Balance Point Solid grouted design would not be conservative. More Complex design should be used for compression controlled points.
31
Masonry Code Resources
American Concrete Association Portland Cement Association Masonry Standard Joint Committee International Building Code
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.