Presentation is loading. Please wait.

Presentation is loading. Please wait.

Audio and Acoustic Analyzer

Similar presentations


Presentation on theme: "Audio and Acoustic Analyzer"— Presentation transcript:

1 Audio and Acoustic Analyzer
Introducing the new flagship of the handheld EXEL line. V1.011, Oct. 09

2 Audio and Acoustic Analyzer
Sound Level Meter Real Time Analyzer

3 Audio and Acoustic Analyzer
Sound Level Meter Real Time Analyzer Acoustic Analyzer

4 Audio and Acoustic Analyzer
Sound Level Meter Real Time Analyzer Acoustic Analyzer STI-PA Analyzer

5 Audio and Acoustic Analyzer
Sound Level Meter Real Time Analyzer Acoustic Analyzer STI-PA Analyzer Audio Analyzer

6 Applications Live Sound Solutions
Sound Installations and Recording Studios Broadcast Environmental Noise Measurements Service and Repair Centers

7 Configurations + M2210 Set XL2 + M2210 XL2 with M Extended Performance - Measurement Microphone with class 1 frequency response Set XL2 + M4260 XL2 with M4260 Measurement Microphone, Class 2 + M4260

8 XL2 Interfaces 8

9 Big LCD 160x160 with Backlight Function Buttons 9

10 Rotary Wheel Limit LED with red, yellow, green Indication 10

11 Shock Protection Jacket 11

12 Headphone Output 12

13 Wire Stand 13

14 Battery Compartment with Li-Po Battery included Rear Speaker 14

15 Balanced & Unbalanced Input Tripod Mount 15

16 Voice Note Microphone 16

17 Mains Power Adapter Input USB Interface Digital I/O
(prepared for later firmware extension) 17

18 Mini-SD Card 2 GByte Removable 18

19 TOSLink Output (prepared for later firmware extension) 19

20 XL2 Key Features

21 Features Flexible User Interface Visual Limit LED of high sound levels
Mini-SD Card, 2 GB removable Real Time Clock Built-in Speaker Rechargeable Li-Po Battery included Automated Sensor Detection reads electronic data sheet of M4260 and M2210 Wave File Recording Voice Notes

22 Sound Level Meter / RTA Applications Live Sound Events
Environmental Noise Monitoring

23 Sound Level Meter / RTA Measures actual level, Leq, Lmin, Lmax, LCpeak, … Frequency weighting A, C, Z Time Weighting F, S, Peak, I* Linear operating range > 100dB XL2 accuracy acc. IEC 61672, class 1 Logs automatically to Mini-SD card Real time clock *optional

24 Sound Level Meter / RTA Extended Acoustic Pack
Percentiles %: 1, 5, 10, 50, 90, 95, 99% Time Weighting: Impulse Sound Pressure Level LIeq Sound Exposure Level LAE TaktMax as specified in DIN High-resolution FFT with 0.4 Hz steps

25 Sound Level Meter / RTA All measurement results are simultaneously available. Select the available levels to be shown on the XL2 display

26 Sound Level Meter / RTA 3 or 5 levels may be displayed simultaneously in different selectable sizes

27 Sound Level Meter / RTA Displays two spectra simultaneously
Resolution selectable Broadband values displayed in parallel Measurement range selectable Measurement time and control

28 Sound Level Meter / RTA Pre-defined limits for all levels
Firmware V1.00 operates with fixed limits Level ok  Limit LED is GREEN Level near limit  LED is YELLOW Limit exceeded  LED is RED

29 Public listening area Stage FOH Loudest accesible position  Audience position Measurement Position k1 = Difference in LAeq k2 = Difference in LCPeak Live Sound Challenges Sound pollution protection limits maximum level in audience area. Loudest audience position is commonly not accessible for measurements. XL2 offers a wizard to measure correction values k1 and k2 between loudest position and measurement point

30 Correction Value Wizard
Run Pink Noise in the auditorium Measure level at the loudest position Measure level at the measurement point, e.g. at the mixing desk FOH XL2 stores results with time stamp and displays the calculated correction values k1 and k2

31 Audio Analyzer Balanced XLR, unbalanced RCA input
-112 dBu to 30 dBu (2.0 uV to 25 V) Residual THD+N <-100dB (0.001%) Frequency range: 9 Hz to 20 kHz Frequency accuracy: 0.003% Loudspeaker and headset output for signal monitoring

32 FFT Analyzer Measures LZF and Leq simultaneously
Real time FFT in 3 linear ranges displayed by 142 frequencies 7 Hz Hz 58 Hz kHz 484 Hz kHz High-resolution FFT including zoom mode up to 0.4 Hz steps with Extended Acoustic Pack in the range from 5 Hz – 20 kHz

33 RT60 Analyzer Measures 8 octave bands from 63 Hz – 8 kHz according to ISO3382 by Schroeder-method Auto triggering Auto averaging Measurement error indication Stimulus: Gated pink noise Impulse sound source

34 Polarity Testing Checks polarity of speaker cabinets, individual drivers and line signals Positive/Negative detection Using internal microphone or input signal of XLR/RCA connector

35 Polarity Testing In-depth verification of the polarity - frequency relation for speaker cabinets or other multi-way-systems Sample Screenshot left: The major part of the signal energy is measured in the mid-range frequency bands, thus the overall displayed polarity is NEGATIVE.

36 Propagation Delay For accurate setup of delay line arrangements
Measures delay between electrical reference and acoustical signal Relative measurements supported Displays distance to speaker in meter or feet

37 STI-PA* Analyzer Measures speech intelligibility of public announcement systems Complies with IEC (2003) and NFPA 72 Displays STI and CIS results Shows table of modulation indices and Leq’s Supports ambient noise post processing *optional

38 Application Profiles XL2 supports application profiles
Application profile may disable and hide any selections or measurement functions Allows fixed operator interfaces for basic users Firmware V1.0 offers a set of fixed application profiles

39 Store and Log Results Results stored as ASCII files
Storing all or subsets of measurements results Adding a voice note to measurement Records the ADPCM compressed audio signal in parallel

40 Automated Sensor Detection
Automatically detects microphone type Reads sensitivity Reads product data Shows last calibration ASD Cable Extension cable tandem up to 20 m supported

41 Powering Concept Rechargeable Li-Po battery included
typical battery lifetime > 5 hours Dry cell batteries type AA, 4 x 1.5 V typical battery lifetime > 4 hours Mains power supply 9 VDC charges Li-Po battery in operation

42 Measurement Microphones
42

43 Measurement Microphones
Omni-directional, pre-polarized condenser, free-field microphone Build-in Pre-amplifier Electronic Data Sheet installed Phantom Power 48 VDC High dynamic range Wide frequency range Low residual noise M2210 M4260

44 Comparison of Microphones
Extended Performance Capsule / Transducer 1/4” permanently installed capsule 1/2” detachable capsule with 60UNS2 thread Flatness Class 2 (IEC ) < ± Hz Hz < ± Hz - 20 kHz Class 1 (IEC ) < ± Hz - 4 kHz < ± Hz - 20 kHz Frequency Range 20 Hz - 20 kHz 1 Hz - 20 kHz Residual Noise Floor typical 24 dB(A) 18 dB(A) Upper Limit of Dynamic Range typ. 136 dBSPL 145 dBSPL Sensitivity typical -30 dBV/Pa ±4 dB (30 1kHz) -34 dBV/Pa ±3 dB (20 1kHz)

45 XL2 Accessories 45

46 Accessories Ever-Ready pouch Detachable front flap
Connectors accessible Zipper EXEL System Case Compartments for XL2, MR-PRO, M4260 or M2210 Accessories, battery and adapter

47 Accessories Battery Charger Includes spare battery
Connects to V AC Intelligent charger controller Spare Battery rechargeable spare battery Li-Po battery

48 Accessories ASD Cable For extended connections of the measurement microphones M4260 or M2210 Maintaining the automated sensor detection Length = 5 meter (16 feet) External AC power supply Suitable also for use with MR-PRO Operates XL2 and chargers Li-Po battery in parallel

49 Firmware Options Extended Acoustic Pack
Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99% Time Weighting: Impulse Sound Pressure Level LIeq Sound Exposure Level LAE High-resolution FFT including zoom mode up to 0.4 Hz steps in the range of 5 Hz - 20 kHz TaktMax and values as specified in DIN

50 Firmware Options STI-PA Option
Measures speech intelligibility of public announcement systems Complies with IEC (2003) and NFPA 72 Displays STI and CIS results

51 New Technologies in Audio