Download presentation
Presentation is loading. Please wait.
117
ABB i-bus® EIB Application Unit Application program Times Groups/1 Programming software PZM1
118
Application Unit AB/S 1.1 Automation functions in buildings
Real-time clock for date and time Logic Time 200 I0 application Functions of a PLC, e.g.: logic operations, gate, timing element, staircase lighting function 200 objects, 50 gates Parameterisation via graphical interface Logging application Logging via EIB and RS 232 to several printers 50 objects and 50 log texts Times Groups/1 application Parameterisation software PZM1
119
Times Groups/1 and PZM1 AB/S 1.1
Overview The application program Times Groups/1 enables the installer to implement complex time switch programs to carry out building automation functions with EIB. The user of the installation can use the parameterisation software PZM1 to adapt the time switch program to his requirements in a very simple way. The flexibility in the operation of the system, e.g., in a school is therefore guaranteed.
120
Times Groups/1 and PZM1 AB/S 1.1
Overview The application program Times Groups/1 contains a year timer with week and day routines enables parameterisation via a graphical interface data is stored in the ETS2 database group addresses are transmitted in both directions Programming software PZM1 operates under Windows without ETS2 same operation as above with restricted function setting of date, time, daylight saving time, etc. modification of switching times, day routine, week routine, etc. (redefinition and modification of group addresses is not possible)
121
Times Groups/1 and PZM1 AB/S 1.1
4. The time switch program is transferred to the user of the EIB installation by the installer 3. Time switch program is exported 2. Project data is stored in the ETS2-DB, AB/S is downloaded 5. Parameterisation soft- ware PZM1 on user´s PC ETS EA/S 232.5 1. Installer of the EIB installation assigns parameters with ETS Application unit AB/S 1.1 6. Time switch program is imported PZM1 7. The user of the EIB installation adapts the time switch program to his requirements and transfers it to the AB/S
122
Times Groups/1 and PZM1 AB/S 1.1
Terms Time switch program Defines when bus telegrams with specific group addresses and specific values are sent on the bus. Day routine Contains the time switch program for a day between 00:00 and 23:59. Day routines can be activated and deactivated by the time switch program and bus telegrams. Week routine Defines the assignment of day routines to the days of the week. Special days Individual days or periods that deviate from the normal week routine. Wenn zu bestimmten Zeiten immer wieder mehrere Bustelegramme mit bestimmten Gruppenadressen und bestimmten Werten gesendet werden sollen, dann können diese in einer sogenannten Menge zusammengefasst werden. Man kann eine Menge daher auch als Funktionsgruppe bezeichnen.
123
Times Groups/1 and PZM1 AB/S 1.1
Terms Group “Functional group” is a combination of group addresses which are sent at the same time. Group members Group addresses that belong to a group. Group triggers Group addresses which trigger a functional group. The type and value of the trigger group address influences the group function. „0“ switches ON, „1“ switches OFF Value < 230 switches ON, value > 250 switches OFF The behaviour on bus failure (read value or use initial value) can be selected.
124
Times Groups/1 and PZM1 AB/S 1.1
Functions Addresses and objects 250 group addresses 250 objects 250 associations Time switch program 15 day routines 800 switching times 1 week routine 100 special days 5 years of daylight saving times in advance Groups 20 groups 300 group members At least 1 group trigger
125
Times Groups/1 AB/S 1.1 Screen Shot
126
PZM1 AB/S 1.1 Screen Shot