Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: (a) Active compression brace, (b) experimental setup, and (c) active compression brace wrapped around the calf
2
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: Cyclic tests setup: the ACB was wrapped around a rigid leg mannequin having the PicoPress probe in the interface
3
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: Cyclic tests results for three trials of applied current: (a) 100 mA, (b) 150 mA, and (c) 200 mA
4
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: (a) A representative example from one of the participants showing the trace of total interface pressure exerted by the ACB on the calf and applied electrical current and (b) experimental and simulation results for actuation pressure versus applied current per SMA wire
5
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: Experimental and simulation differences versus current for each participant
6
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: Relationships between RMSD of simulation and experimental results with calf CSA minus calf fat CSA
7
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: (a) NRMSD between simulation and experimental results for produced pressure by ACB before and after analytical model calibration (a) for each applied current and (b) for each participant
8
Date of download: 10/8/2017 Copyright © ASME. All rights reserved. From: A Shape Memory Alloy-Based Compression Therapy Prototype Tested With Individuals in Seated Position J. Med. Devices. 2017;11(4): doi: / Figure Legend: Mean and standard error of participant ratings of comfort obtained (a) after the human tests with ACB and (b) after comparative tests of three different devices