1 SALIENT FEATURES OF 500 MW BOILER
TYPE OF BOILER: Single Drum Top supported, Fusion welded WW Panel, Controlled circulation system, Tangential fired, Radiant Dry Bottom Pulverized coal fired outdoor Balanced Draught Cut corner 51mm OD WW Tubes at 63.5 mm pitch Rap around Buck stay system FIRST PASS: Boiler Furnace Depth mtr Furnace Width mtr Height of Furnace (upto Radient roof) mtr. SECOND PASS: Depth mtr Width mtr Total Height of Boiler- 90mtr.

2 BOILER EXPANSION DETAILS
FIRST PASS: Vertically Downward Expansion at Ring Header (10.250mtr elev.) : 330mm Horizontal Expansion at Ring Header (10.250mtr elev.) : 36mm SECOND PASS : Vertically Downward Expansion at Ring Header (44.060mtr elev.) : 174mm (44.060mtr elev.) : 58mm

3 BOILER DRUM EXPANSION :
Vertical Downward Expansion at mtr elev.=29mm Horizontal Expansion at mtr elev.= 53mm

4 BOILER PARAMETERS (BMCR)
STEAM FLOW AT SH OUTLET t/h PRESSURE OF SUPERHEATED STEAM kg/sq.cm TEMP.OF SUPERHEATED STEAM C STEAM FLOW AT REHEATER OUTLET t/h ENTRY PRESSURE OF REHEATED STEAM kg/sq.cm ENTRY TEMP. OF REHEATED STEAM C EXIT PRESSURE OF REHEATED STEAM kg/sq.cm EXIT TEMP. OF REHEATED STEAM C FEED WATER INLET TEMP C FEED WATER TEMP BEFORE ECO C FEED WATER TEMP AFTER ECO C

5 TEMP.AT LTSH OUTLET C TEMP.AT S/H DIVISIONAL OUTLET C TEMP.AT FINAL S/H OUTLET C

6 DESIGN PARAMETERS OF BOILER
BOILER DRUM PRESSURE kg/sq cm SH OUTLET PRESSURE kg/sq cm FINAL SH TEMP C REHEATER OUTLET PRESSURE kg/sq cm BOILER HYD. TEST PRESSURE kg/sq cm REHEATER HYD. TEST PRESSURE kg/sq cm

7 HEATING SURFACE OF BOILER
ECONOMISER sq mtr WATER WALL sq mtr STEAM COOLED WALL sq mtr LTSH sq mtr SH DIVISIONAL PANELS sq mtr PLATEN SH (FINAL SH) sq mtr SH ROOF sq mtr RH FRONT COILS sq mtr RH REAR COILS sq mtr TOTAL HEATING SURFACE AREA = sq mtr

8 WATER HOLDING CAPACITY OF BOILER
BOILER DRUM (FULL) : cubic mtr CIRCULATION SYSTEM : cubic mtr ECONOMISER : cubic mtr SUPERHEATER(LTSH,SH Div. Panel, Final SH): 130 cubic mtr REHEATER : cubic mtr TOTAL VOLUME : cubic mtr DM WATER REQUIRED FOR HYD. TEST (DRAINABLE) : cubic mtr

9 SOOT BLOWER DETAILS WALL SOOT BLOWERS : 88 Nos. (FUTURE - 16 Nos.)
(FRONT & REAR AT EACH ELEVATION - 6 Nos. EACH, RHS &LHS -5 Nos. EACH, TOTAL 4 ELEVATIONS) LRSB : 40 Nos. (FUTURE - 4 Nos.) APH SOOT BLOWERS :2 Nos.

10 COMPARISON BETWEEN NATURAL & ASSISTED CIRCULATION BOILERS
S/H S/H DRUM DRUM BOILER WALLS BOILER WALLS ECO ECO CC PUMP FEED LINE FEED LINE RING HEADER RING HEADER NATURAL CIRCULATION BOILER (SUB CRITICAL BOILER 30MW-250MW) DRUM CG. 26 MTR – 58 MTR ASSISTED CIRCULATION BOILER (500MW) DRUM CG – MTRS FORCE CAUSING FLOW OF WATER THROUGH TUBES F = WCOLD X H1 - W HOT X H2

11 CRITICAL BOILERS OR ONCE TROUGH OR MONOTYPE BOILER
S/H STEAM BOILER WALLS SEPERATOR WATER ECO DRAIN FEED PUMP

12 IMPORTANT FEATURES OF 500 MW BOILER
C.C. PUMPS ORIFICE PLATES IN BOTTOM RING HEADER RIFLED TUBES IN WATER WALLS DIVISIONAL SUPERHEATERS ECO LINK CONNECTIONS FROM BOTTOM OF BOILER DRUM DOWN COMMERS CONNECTION TO ONLY BOTTOM RING HEADER. ECO RECIRCULATION CONNECTION TO BOTTOM RING HEADER REAR. 2 NOS. TRISECTOR TYPE AIR PREHEATERS. 8 NOS. BOWL MILLS ( XRP 1043 TYPE) & GRAVEMETRIC 36” SIVE FEEDER ( FEEDER LOCATION 21 ML ) 4 NOS OIL ELEVATION & 8 NOS. COAL ELEVATION. 2 NOS. I.D FANS, 2 NOS. F.D.FANS, 2 NOS. SEAL AIR FAN, 11 SILENCERS , 20 SAFETY VALVES HEA INNITERS. COAL CONSUMPTION – 8400 T/HR.

13 NUMBER OF TUBES & DIAMETERS
DESCRIPTION NO. OF TUBES / PANELS DIAMETER OF TUBE IN MM RISER TUBES( W/W O/L HDR. TO DRUM) 68 NOS. 159 WATER WALL ( FUSION WELDED ) FRONT-269 NOS., REAR-269 NOS, LHS-212 NOS, RHS-212 NOS. 51 HANGER TUBES 44 NOS. 63.5 SCREEN TUBES 177 NOS. REAR ARCH EXTENDED SIDE W/W PANEL LHS-37 NOS.& RHS-37 NOS. ECONOMISER 92 X 3 BANKS 38.1 LTSH 62 X 2 BANKS 47.63 DIVISIONAL PANELLETE 6 ASSY. & 8 PANELS i.e. 48 NOS. 44.5 FINAL SUPERHEATER 25 COILS REAHEATER FRONT-74 NOS. & REAR 74 NOS. 54 RADIENT ROOF 1ST PASS 150 NOS. SUPER HEATER CONNECTION TUBES(DRUM TO RADIENT ROOF ) 21 NOS. B.P. SIDE WALL ( FRONT ) 60 NOS. B.P. SIDE WALL ( REAR ) 31 NOS. B.P. ROOF TUBES 126 NOS. B.P.FRONT SCW TUBE B.P.REAR WALL TUBE 137 NOS.

14 SAFETY VALVES LOCATION
M.S.LINE HRH LINE CRH LINE DRUM SAFETY VALVE 2 4 6 ERV (ELECTROMATIC RELIEF VALVE)