P11073-10207 Status Ballot results, major changes
HL7 International Conference & Working Group Meeting, Madrid, 05/09/2017 Dr. David Gregorczyk
2
Agenda 1 First Round Ballot Results 2 Latest Changes from Comments
3 Clarifications / Findings P Status | Dr. David Gregorczyk | 05/09/2017
3
Agenda 1 First Round Ballot Results 2 Latest Changes from Comments
3 Clarifications / Findings P Status | Dr. David Gregorczyk | 05/09/2017
4
First Round Ballot Results
Balloting of Draft 6, closed on 3rd March 29 Balloters 76 comments Response rate: 96% Approval rate: 84% Abstain rate: 7% Next balloting phase is running and closes on 17th May Still no comments submitted yet P Status | Dr. David Gregorczyk | 05/09/2017
5
Agenda 1 First Round Ballot Results 2 Latest Changes from Comments
3 Clarifications / Findings P Status | Dr. David Gregorczyk | 05/09/2017
6
General Typographic mistakes Missing or misleading explanations
Missing bibliography/normative references P Status | Dr. David Gregorczyk | 05/09/2017
7
Alert system wide signal state
Comment Add info about audible and visual signal system state in order to allow better modelling of audio pause. Each subsystem should have its own activation state. Activationstate of the AlertSystem then reflects only the general condition monitoring. Remedy Insert SystemSignalActivation attribute to AlertSystem, which describes a compound alert signal activation for audible, visible, and tangilbe alert signals P Status | Dr. David Gregorczyk | 05/09/2017
8
Revised birthday mode Comment
Birthday model does not match HL7 model, e.g., - HL7 v2 PID-7 or HL7 FHIR extension. Remedy Adapted FHIR solution in pm:PatientDemographicsCoreData/pm:DateOfBirth P Status | Dr. David Gregorczyk | 05/09/2017
9
Component type without alert system
Comment There are cases where a device component should not possess an alert system, e.g. SCO, Clock, and SystemContext. Remedy Introduced intermediate type in accordance to naming scheme: pm:AbstractAlertingDeviceComponentDescriptor for any component that supports alert systems. Components without alert systems remain pm:AbstractDeviceComponentDescriptor P Status | Dr. David Gregorczyk | 05/09/2017
10
AlertSignalState finite state machine
Comment This finite state machine is not proven to be correct, nor will it be possible to cover every device's internal alarm logic. Remedy Figure will be moved to annex as a sample instance Inserted a table with valid activation and presence flags combinations instead P Status | Dr. David Gregorczyk | 05/09/2017
11
Archive service descriptor retrieval
Comment In order to allow the retrieval of a descriptor/state range make Descriptor revision have a start and an end revision index. Remedy Added a version frame parameter named DescriptorRevisions to msg:GetDescriptorsFromArchive and msg:GetStatesFromArchive P Status | Dr. David Gregorczyk | 05/09/2017
12
Battery object Comment
Add objects that represents the battery/power supply of the mds Remedy Added an optional battery descriptor and state that represents battery information pm:BatteryDescriptor pm:BatteryState Information is taken from classic DIM. Some explanations have been improved based on information taken from IEC (International Electrotechnical Vocabulary) P Status | Dr. David Gregorczyk | 05/09/2017
13
SCO object Comment For modular systems, modules that are dynamically plugged/ removed would typically be modeled as VMDs. Such VMDs potentially have their own remote control capabilities. So it would seem that the VMD could also have SCO objects, similar to its own AlertSystem Remedy Added optional SCO to pm:VmdDescriptor P Status | Dr. David Gregorczyk | 05/09/2017
14
LifeTimePeriod Comment
Consider adding a "life-time" period. Example: a non-invasive pressure is measured intermittently. Some application shows the data, e.g. with a time stamp. After a specific time, the value is not useful anymore, its lifetime has expired. Remedy Added LifeTimePeriod attribute to pm:AbstractMetricDescriptor and pm:AbstractMetricState P Status | Dr. David Gregorczyk | 05/09/2017
15
Manually derived measurements
Comment Metric Category should also contain an enumeration for a manually derived measurement that is entered by a clinician and may need to be flagged accordingly. This is frequently done in spot-check situations. Remedy Added attribute „DerivationMethod“ to designate if a metric value is derived automatically or manually P Status | Dr. David Gregorczyk | 05/09/2017
16
Agenda 1 First Round Ballot Results 2 Latest Changes from Comments
3 Clarifications / Findings P Status | Dr. David Gregorczyk | 05/09/2017
17
Clarifications / Findings
Are there any things that we should clarify here? Examples: Metrics Alert Systems Contexts Remote Control Versioning Any comments we should bring into the actual balloting round? P Status | Dr. David Gregorczyk | 05/09/2017
18
Thank you for your attention.
David Gregorczyk System Architect Schlussfolie / Final Slide: Platz für Namen, Position und Kontaktdaten des Verfassers / Room for author's name, position and contact details Oder: Aufforderung zur Diskussion / Or: prompt a discussion Oder: "Vielen Dank für Ihre Aufmerksamkeit." / Or: "Thank you for your attention."