2015 NSBOA code updates Part 9 and Part 3.

Similar presentations


Presentation on theme: "2015 NSBOA code updates Part 9 and Part 3."— Presentation transcript:

1 2015 NSBOA code updates Part 9 and Part 3

2

3 Code Changes- Part 9, Housing & Small Buildings
Volume 2 of the National Building Code is now essentially Part 9 including Appendix A. STAIRS Permitted configurations (1) (c) Spiral stairs now permitted as long as they comply with 2010 2015

4 Code Changes- Part 9, Housing & Small Buildings
Volume 2 of the National Building Code is now essentially Part 9 including Appendix A. The minimum and maximum rise for stairs remains unchanged. 2015 2015 2015

5 Code Changes- part 9, Housing & Small Buildings
Volume 2 of the National Building Code is now essentially Part 9 including Appendix A. (2) A curved flight used as an exit shall have: (a) Handrail on each side (b) A minimum run of 240 mm (9 ½) (c) A run not less than 288 mm (11’’) when measured at a point 300 mm (12”) from the center line of the handrail at the narrow end of the tread (d) An inside radius that is not less than twice the stair width

6 Code Changes- part 9, Housing & Small Buildings
Stair run has changed Minimum run for private stairs was 210 mm ( 8 ¼ inches) in 2010 NBC, now changed to 255 mm (10 inches) in 2015 NBC. 2015 Note: The increased minimum run of the stairs will affect the size of the stairwell opening required to maintain the minimum headroom requirement of 6’4 ¾ “. As well, a 2 x 12 may be required for a stair stringer as it is necessary to maintain a minimum 3 ½ inch uncut portion of the stringer.

7 Code Changes- part 9, Housing & Small Buildings
Previous Code- Referred to “Angled” treads New Code- Refers to “Tapered” treads 2010 2015 Note: The increased minimum run of the stairs will affect the size of the stairwell opening required to maintain the minimum headroom requirement of 6’4 ¾ “. As well, a 2 x 12 may be required for a stair stringer as it is necessary to maintain a minimum 3 ½ inch uncut portion of the stringer.

8 Code Changes- part 9, Housing & Small Buildings

9 Code Changes- part 9, Housing & Small Buildings
2010 2015

10 Code Changes- part 9, Housing & Small Buildings
2015 2015

11 Code Changes- part 9, Housing & Small Buildings
2015 Code Changes- part 9, Housing & Small Buildings 2010 2015

12 Code Changes- part 9, Housing & Small Buildings
Dimensions of Landings Change from Table Eliminated

13 Code Changes- part 9, Housing & Small Buildings
Dimensions of Landings (Continued)

14 Code Changes- part 9, Housing & Small Buildings
Required Handrails Table is Unchanged

15 Code Changes- part 9, Housing & Small Buildings
Required Handrails 2010 Sentence 2 is changed 2015

16 Code Changes- part 9, Housing & Small Buildings
Continuity of Handrails 2010

17 Code Changes- part 9, Housing & Small Buildings
Continuity of Handrails 2015

18 Code Changes- part 9, Housing & Small Buildings
Continuity of Handrails 2015

19 Code Changes- part 9, Housing & Small Buildings
Continuity of Handrails 2015

20 Code Changes- part 9, Housing & Small Buildings
Height of Handrails 2010

21 Code Changes- part 9, Housing & Small Buildings
Height of Handrails 2015

22 Code Changes- part 9, Housing & Small Buildings
Ergonomic Design 2010

23 Code Changes- part 9, Housing & Small Buildings
Ergonomic Design 2015

24 Code Changes- part 9, Housing & Small Buildings
Opening in Guards 2010

25 Code Changes- part 9, Housing & Small Buildings
Opening in Guards 2015

26 Code Changes- part 9, Housing & Small Buildings
Design of Guards to no Facilitate Climbing 2010 2015

27 Code Changes- part 9, Housing & Small Buildings
Small Garages 2010 2015

28 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission Section 9.11 has been rewritten New Terminology Apparent Sound Transmission Class (ASTC) mean a single number rating of the airborne sound attenuation of building assemblies separating two adjoining spaces taking into account both the direct and flanking sound transmission paths. STC by definition considers only the direct sound transmission paths.

29 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission

30 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission

31 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission

32 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission

33

34

35 Code Changes- part 9, Housing & Small Buildings
9.11- Sound Transmission

36

37 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010

38 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010

39 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010

40 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010 2015

41 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010 2015

42 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2010

43 Code Changes- part 9, Housing & Small Buildings
9.13- Dampproof, Waterproofing and Soil Gas Control 2015

44 2015 NSBOA code updates Part 3- Large Buildings

45 Code Changes- part 3, LARGE BUILDINGs

46 Code Changes- part 3, LARGE BUILDINGs
Continued Addition of Sentences 2 & 3

47 Code Changes- part 3, LARGE BUILDINGs
Sentences 3 & 4 from 2010 Code removed

48 Code Changes- part 3, LARGE BUILDINGs
New

49 Code Changes- part 3, LARGE BUILDINGs
New

50 Code Changes- part 3, LARGE BUILDINGs
Continued

51 Code Changes- part 3, LARGE BUILDINGs
New

52 Code Changes- part 3, LARGE BUILDINGs
Continued

53 Code Changes- part 3, LARGE BUILDINGs
New- Continued

54 Code Changes- part 3, LARGE BUILDINGs
– Addition of Sentences 6, 7, 8

55 Code Changes- part 3, LARGE BUILDINGs
Was – Rewritten, addition of sentence 5 & 6

56 Code Changes- part 3, LARGE BUILDINGs
Continued

57 Code Changes- part 3, LARGE BUILDINGs
Part 3 - Changes 2010

58 Code Changes- part 3, LARGE BUILDINGs
Part 3 - Changes continued 2015

59 Code Changes- part 3, LARGE BUILDINGs
Part 3 – Changes Fire blocks in Horizontal Concealed Places Addition of Sentences 3 & 4

60 Code Changes- part 3, LARGE BUILDINGs
Superimposed Major Occupancies Addition of Sentences 3 & 4

61 Code Changes- part 3, LARGE BUILDINGs
Part 3- Changes Group D Changes allows combustible construction up to 6 storeys if the building is Sprinklered Group C, up to 6 Storeys Sprinklered: Change allows up to 6 storeys with non-combustible construction

62 Code Changes- part 3, LARGE BUILDINGs
New, Part 3- Changes

63 Code Changes- part 3, LARGE BUILDINGs
Part 3- Changes Addition of Sentence 2

64 Code Changes- part 3, LARGE BUILDINGs
Part 3- Changes Direction of Door Swing- Addition of Sentence (2) Distance Between Exits- Addition of Sentence (4)

65 Code Changes- part 3, LARGE BUILDINGs
New, Part 3- Changes

66 Code Changes- part 3, LARGE BUILDINGs
Part 3- Changes Code Changes- part 3, LARGE BUILDINGs New Section

67 Code Changes- part 3, LARGE BUILDINGs
Part 3- Changes Code Changes- part 3, LARGE BUILDINGs New Section

68 Thank you for attending the 2015 NSBOA Code Update Seminar


Download ppt "2015 NSBOA code updates Part 9 and Part 3."