ANSI/SPRI ES-1 Metal Edge Systems
3
ES-1 Edge Systems Why should you specify and require ES-1 tested edge metal system with all of your low slope roofing systems? It’s good roofing practice. It’s required by BUILDING CODE. It provides the best overall value and long term performance for your ACCOUNT.
4
ES-1 Testing Standard ANSI/SPRI ES : Wind Design Standard for Edge Systems used with Low Slope Roofing Systems Required by the 2003, 2006, 2009 IBC and the 2007 FBC.
5
ES-1 Testing Standard ANSI/SPRI ES : Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems IBC Section : Low-Slope Membrane Roof System Metal Edge Securement , Except Gutters, Shall Be Designed and Installed For Wind Loads In Accordance With Chapter 16 and Tested For Resistance In Accordance With ANSI/SPRI ES-1 2007 Florida Building Code: Requires RAS-111 or ANSI/SPRI ES-1 RICOWI (Roof Industry Committee on Weather Issues) Study of 145 FM Roof Losses Shows 59% of Losses Due To Failure of Edge Metal
6
ES-1 Testing Standard RE-2 Fascia Test
7
ES-1 Testing Standard RE-3 Coping Test
8
ES-1 Certified Edge Metal
Anyone Can Have Their Fabricated Edge Metal System Tested In Accordance With ES-1 at Any Qualified Testing Laboratory National Manufactures: Including Garland, There Are 3 Major National Manufacturers That Provide ES-1 Tested Edge Metal Systems Many Other Low Slope Roofing Manufacturers Offer ES-1 Tested Edge Metal Systems Under Private Label Agreement With the National Manufacturers Other Regional Manufacturers and Sheet Metal Fabricators Have ES-1 Tested Systems Available NRCA Fabricator Certification Program
9
NRCA Program Not All NRCA Member Roofing Contractors May Make ES-1 Certified Metal Edge Systems Must Be NRCA Member Company Must Apply For Edge Metal Program Including Fees: $5,500 Initial Application Plus $1,350/Year Must Have Two On-site Facility Inspection By Intertek Testing Laboratory Must Form Parts and Have Them Tested In Intertek’s Laboratory With Applicable Additional Testing Charges
10
NRCA Program Program Facts:
Only 104 Roofing Contractors Nation-Wide Participate In Program; Total Participation Has Not Increased In Recent Years Limited Profiles Tested and Approved: Two Raised Edge Metal Profiles With Exposed Hex Head Fasteners Two Embedded Gravel Stop Profiles; Must Be Stripped-in To Be Water-tight Seven Coping Profiles Of Different Configurations; Each Uses Exposed Hex Head Screws or Hand Crimped Drip Hems or Both No Snap Down Facia or Coping Systems!
11
Typical NRCA Approved System
12
2,000 feet of Coping and Miters
R-Mer Edge Coping Eudora Middle School Greg Leslie 2,000 feet of Coping and Miters
13
R-Mer Edge Coping Features and Benefits:
Fully Tested For ANSI/SPRI ES-1 Compliance 24 and 22 Gauge Steel, and .040” and .050” Aluminum Prepainted Materials .040”, .050”, and .063” Post-Painted Aluminum In Any Custom Color Factory Welded and Post-Painted Aluminum Miters, Tees, and Transitions Radius Aluminum Coping: Factory Welded and Post-Painted
14
R-Mer Edge Coping 2009/2010 Design Improvements:
Rear Leg Modified for Increased Strength 16 Gauge x 16” Long Anchor Chairs
15
2,600 feet of Fascia and Coping
R-Mer Edge Fascia Blackwood Elementary Bill Pancoast 2,600 feet of Fascia and Coping
16
R-Mer Edge Fascia Features and Benefits:
Fully Tested for ANSI/SPRI ES-1 Compliance 24 and 22 Gauge Steel, and .040” and 050” Aluminum Prepainted Materials .040”, .050”, and .063” Post-Painted Aluminum In Any Custom Color Standard Sizes of Cant Dam Stocked In Cleveland and Atlanta for On-Schedule Building Dry-In
17
R-Mer Edge Fascia 2009/2010 Design Improvements: Easier installation
More efficient fabrication Easier to package, stock, and ship. Fully Tested for ANSI/SPRI ES-1 Compliance
18
R-Mer Edge Extruded Fascia
19
R-Mer Edge Extruded Fascia
Fascia Cover is Heavy Gauge Aluminum Extrusion Available In 6”, 7”, 7-3/4”, 8-1/2”, 9-1/4”, and 10” Face Stocked In Mill Finish; All Colors are Post-Painted Kynar; Ideal for Custom Color Applications Fully Tested for ANSI/SPRI ES-1 Compliance: Highest Strength Metal Edge System Available Can Be Furnished To Fit Curved Wall
20
ES-1 Certified Edge Metal
How Will This Affect My Roofing Budget? 250 Square Roof With 700 lf of .050” Fascia: Add $4,500 ($0.18/sq ft) as Compared to NRCA Style Shop Fabricated System Add $5,500 ($0.22/sq ft) as Compared to Non-Compliant Drip Edge 1,200 Square Roof with 1,600 lf of Coping and 1,000 lf of Fascia: Add $18,500 ($0.15/sq ft) as Compared to NRCA Style Shop Fabricated System Add $22,000 ($0.18/sq ft) as Compared to Non-compliant Sheet Metal Coping
21
Product Support Installation Instructions
22
Product Support Installation Instructions Performance Specification
23
Product Support Installation Instructions Performance Specification
Wind Resistance Calculations
24
Product Support Installation Instructions Performance Specification
Wind Resistance Calculations ES-1 Test Reports
25
Garland R-Mer Edge HOW To Offer Garland ES-1 Tested Edge Metal Systems: Budget For It! Specify It! Require Substitutions Requests To Be Submitted Prior To Bid and Include The PE Sealed Product Test Report Inform Your Account To Recognize The Value of Having A Tested and Building Code Compliant Edge Metal System Protecting Their Investment
26
Garland R-Mer Edge Don’t forget WHY: It’s Good Roofing Practice
It’s Required By BUILDING CODE It Provides The Best Overall Value and Long Term Performance For Your ACCOUNT
27