Presentation is loading. Please wait.

Presentation is loading. Please wait.

THREE-PHASE TRANSFORMER

Similar presentations


Presentation on theme: "THREE-PHASE TRANSFORMER"— Presentation transcript:

1 THREE-PHASE TRANSFORMER
CHAPTER 5 THREE-PHASE TRANSFORMER Electrical Machines

2 INTRODUCTION A three-phase transformer can be obtained in two different ways. Three numbers of identical single-phase transformers can be suitably connected to make a three-phase transformer. Such three-phase transformers are called a bank of three-phase transformer. Alternatively, a three-phase transformer can be constructed as a single unit. Electrical Machines

3 ADVANTAGES OF SINGLE UNIT THREE-PHASE TRANSFORMER
1. It occupies less space 2. Its weight is less 3. Its cost is comparatively less 4. It is much easier to transport 5. It is more efficient 6. Core size is comparatively small. Electrical Machines

4 DISADVANTAGES OF SINGLE UNIT THREE-PHASE TRANSFORMER
When one of the phases of a single-unit three-phase transformer becomes faulty, the entire unit of three-phase transformer needs to be removed from the supply for repair. But in the case of a bank of three-phase transformer, only the faulty transformer is removed from the supply for repair while the other two transformers remain connected in the system without interrupting the supply completely. Electrical Machines

5 CONSTRUCTION Core type Shell type Electrical Machines

6 Star–Star (Υ–Υ) Connection of Three-phase Transformer
Electrical Machines

7 Delta–Delta (Δ–Δ) Connection of Three-phase Transformer
Electrical Machines

8 Delta–Star (Δ –Υ) Connection of Three-phase Transformer
Electrical Machines

9 Star–Delta (Υ–Δ) Connection of Three-phase Transformer
Electrical Machines

10 Open Delta (V–V) Connection of Three-phase Transformer
Some of the features of open delta connection are • The power handling capacity of open delta circuit is times that of delta–delta circuit. • The secondary terminal voltage becomes unbalanced with increase in load. • The power factor is 86.6% of the balanced load factor. • The two transformers in open delta connection will be operated at different power factor. Electrical Machines

11 Scott (T–T) Connection of Transformer
It is a type of circuit used to derive two-phase electric power from a three-phase source, or vice-versa. The Scott connection evenly distributes a balanced load between the phases of the source. Electrical Machines

12 CONVERSION FROM THREE-PHASE TO TWO-PHASE
Electrical Machines

13 Double Star Connection
Electrical Machines

14 Double Delta Connection
Electrical Machines

15 Six-phase Star Connection
Electrical Machines

16 Diametric Connection Electrical Machines

17 Advantages of using tertiary winding in transformer
i) This transformer has the ability to redistribute the flow of fault current ii) It reduces the unbalancing in the primary due to unbalancing in three-phase load. iii) Auxiliary load at different voltage levels from the tertiary winding can be supplied from this transformer in addition to its main secondary load. Electrical Machines