ComCam Interfaces Travis Lange ComCam TDR May 10, 2017
2
Outline Mechanical Interfaces Utility Interfaces Software
Cryostat to L3 flange Cryostat to ComCam Sled Utility Box to ComCam Sled Utility Interfaces TMA Bulkhead to Utility Box Block Diagram Software HCU control logic
3
ComCam Layout ComCam Sled Utility Box Refrigeration Pathfinder Volume
Cryostat Stage Assy Corrector Optics, Shutter and Filter Changer
4
Mechanical Interfaces
Utility Box to ComCam Sled Utility Box to Refrigeration Pathfinder Utility Box to TMA Bulkhead Cryostat to L3 Flange Cryostat Stage Assy to ComCam Sled
5
Utility Box Interface Definition Drawing
Credit: Scott Newbry
6
Cryostat Interface Definition Drawing
Credit: Justine Haupt
7
Utilities at Bulkhead Plate: LSE-64
380VAC 3-phase power Stepped down to 220VAC single-phase DAQ Fibers (12 multi-strand) Using 1 of the DAQ fibers CCS Fiber (1 multi-strand) 2 Copper Communications Wires May use 1 wire for Master Control Module…TBD 22 Refrigeration Hoses (+5 for spares) N/A for utility box Dynalene supply and return Cooling utility box volume, cryotels and power supplies Clean Dry Air Purging of utility box volume
8
ComCam Block Diagram Filter Changer and Shutter
Power Conversion: 380VAC 3-phase to 220VAC single-phase CCS Fiber Dynalene Coolant DAQ Fiber Cryostat Stage Assembly Filter Changer and Shutter
9
Interface to Refrigeration Pathfinder
Not specifically covered in this review Mechanical volume (Ø940mm x 771mm) for pathfinder at back of utility box Utilities needed for refrigeration pathfinder Turbo pump and controller Ion pump and controller HCU Cryo and cold system heaters Vacuum gauges, readout and power supply RTDs and digitization electronics Pressure transducers and digitization electronics VQM Gate valves and pneumatic controls for valves Protection system?
10
Interface to Refrigeration Pathfinder
Very little work on refrigeration pathfinder currently Interface to Utility Box not well defined Based on current layout with “I&T” HX in the ComCam model, refrigeration team confirms 3 circuit system will fit LCN generated for FY18 funding of refrigeration pathfinder Design to begin in FY18
11
Software Interface Components within utility box specified to be same as Camera utility trunk components wherever possible For the same components, CCS will already have control scripts For new/different components, CCS will need to create new controls Current architecture has one HCU to control the cryostat and another HCU to control the filter changer and shutter Camera utility trunk has many more HCUs Control logic for startup/cooldown most likely different from Camera Startup/cooldown procedures for the cryostat are being defined now in TS7/TS8 CCS and DAQ can accommodate ComCam on the TMA and Camera testing in the maintenance area (or vice versa)