1
FIDEGAS Gas detection systems
2
FIDEGAS CA presentation
Control unit for the detection of toxic and explosive gases provided with standard 4-20mA input for 2, 4 & 8 detectors. Exclusively developed to be installed with FIDEGAS S/3 (EEx d II C T6) detectors. Cover (keypad) in English & Spanish FIDEGAS CA is provided of: 2 actuation levels: Prealarm and Alarm Available outputs at 12V DC, 230V AC & D.C. Alarm & cabling fault indicators LEDs: prealarm, alarm, fault, 100% L.E.L., auxiliary battery Events memory Connection cable: Halogen free shield cable with 1mm2 section for a maximum length of 250 m. Control unit & detector EARTH connected ATEX certificate issued by Madariaga Official Laboratory LOM 03ATEX2095 when FIDEGAS S/3 detectors are connected.
3
FIDEGAS S/3. Exproof detectors
available gases FIDEGAS S/3-2 Explosives FIDEGAS S/3 T1 & T2 Toxics For other gases, consult EEx d II C T6
4
1 2 FIDEGAS S/3. Exproof detectors
maintenance Each filter/sensor has its own electronic circuits Do not swap sensors or circuits. Recalibrate FIDEGAS S/3 detector every 2 years during its working life (at manufacturer´s factory) Check the correct functioning of the detector with testing gas every 6 months 1 2
5
FIDEGAS S/3. Exproof detectors
maintenance Dissassemble and replacement of FIDEGAS S/3 detector Release the cables from the connector marked with 1, 2, 3, & Earth connection. Releasing the self-blocking take out the whole set (cable + connector/s). 2. Release sensor´s connector. 3. Unscrew the filter/sensor. Do not twist the flat cable, neither hook it with other elements. 4. Electronic circuit can be dissassembled after releasing 2 subjection screws. Each filter/sensor has its own electronic circuit Do not swap sensors or circuits.
6
FIDEGAS CA Quick installation guide
7
Place the connector in those non used connectors
FIDEGAS CA Quick installation guide 1. Mount on the wall the control unit (door to be opened from left to right). 2. Control unit´s bag includes the following replacements: 2 1A fuses Thermal retractable tube to isolate the detector-panel shield connection cable avoiding short-circuits Conectors It allows the correct functioning of the panel when one or more are not connected (or if they has been disconnected for revisions). Screw M-4. Electronic circuit 3. Control unit – detector connection Fuse 1A. Protect the detectors. All fault LEDs lightining up mean blowed fuse Connect: control unit-detector Isolate the shield using the thermal retractable tube and connect it to EARTH in the proper connector. Place the connector in those non used connectors
8
FIDEGAS CA Quick installation guide 230V CA Outputs 12V CC Outputs
Do the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 230V and total consumption does not exceed the B fuse value of 2A. FIDEGAS CA2. Conector 230V AC PREALARM: This output its timed to activate the extraction during 2 minutes. IT SHOULD NOT ACTIVATE ALARMS Between C & NO (ALARM) Between C & NC (GAS CUT) 12V CC Outputs Do the connection between C & NC or C & NO, being sure that the devices connected (electrovalve, contactor, siren, etc.) work at 2V and total consumption does not exceed the C fuse value of 0,5A. Example of 12V output connection to an electrovalve FIDEGAS CA2. Conector 12V DC Dry contact (close contact and no powered). Between C & NC (ALARM) Between C & NO (GAS CUT) CONSIDERATIONS: When connecting 230V -or after a main fault- wait for 30 s before REARMING the system. Pay attention to the fuses capacity (mentioned in the manual) When all fault LEDs will be lightining up, check the state of the fuse ( D - E )
9
1 2 3 FIDEGAS CA Quick installation guide
FIDEGAS S/3 DETECTORS testing: 1 Put the cap on the sensor head Testing bottle concentration is not suitable for calibration neither precision test. Ii is only recommended to check the detectors correct functioning. 2 Introduce cannula In the cap´s hole 3 Release gas for 2 s. to activate alarm Wait 3 s before releasing more gas as required gas concentration to activate the ALARM keeps 2 m in the mask aprox..
10
FIDEGAS C presentation
Control unit for the detection of toxic and explosive gases for 2, 6 & 12 detectors. Exclusively developed for FIDEGAS S/10 detectors. Cover (keypad) in English & Spanish FIDEGAS C is provided with: 2 actuation levels: Prealarm & Alarm Available outputs at 12V DC & 230V AC LEDs: Power, prealarm, alarm, output Rearm push button Prealarm Output FIDEGAS S/10 detector Power supply: 12V DC Consumption: 120 mA Type of sensor: Catalytic Useful life: 5 years Coverage area: 15 m2 Available for: Natural gas (Methane), Butane-Propane Measurement range: From 0 to 100% L.E.L. Protection Grade: IP 435
11
Stand-alone detectors
12
FIDEGAS C30 presentation Stand-alone EXPROOF detector (EExd II C T6) for explosive gases (Natural gas-Methane-, Butane-Propane, Hydrogen) provided with a relay output for acting when gas presence reaches a level equal or higher than 20% Low Explosive Limit (L.E.L.). Available at 12V or 24V. Coverage area: 16 m2 aprox. Type of sensor Catalityc (with synterized metal) Alarm level 20% L.E.L. Useful life 4 years Coverage area 16 m2 aprox. Protection grade I.P. 435 Code of explosive atmosphere EEx d II C T6
13
FIDEGAS S/10 stand-alone
presentation Stand-alone detector for explosive gases (Natural gas-Methane-, Butane-Propane,) provided with a relay output for acting when gas presence reaches a level equal or higher than 20% Low Explosive Limit (L.E.L.). Available at 12V or 24V. Coverage area: 16 m2 aprox. Use shield cable 4 x 0,25 mm2 maximum length 300m (4 x 0.50 mm2 – 600 m). Output NC Type of sensor Catalityc Alarm level 20% L.E.L. Useful life 5 years Protection grade I.P. 435
14
applications applications FIDEGAS CA FIDEGAS C Batteries rooms Cellars
Chemical industry Chicken farms Nuclear industry Refrigeration Fertiliser plants Fumigation Grain storage Greenhouses Laboratories Paper mills Water treatment Steel works Swimming pools Food processing applications FIDEGAS C Boiler rooms Kitchens Laboratories
Similar presentations