TCT BLM response from tertiary halo at 6.5 TeV

Similar presentations


Presentation on theme: "TCT BLM response from tertiary halo at 6.5 TeV"— Presentation transcript:

1 TCT BLM response from tertiary halo at 6.5 TeV
E. Skordis On behalf of the FLUKA team Input from: R. Bruce E. Skordis Collimation Working Group #206 27/6/2016

2 BLM response history E. Skordis
Collimation Working Group #206 27/6/2016

3 TCTH+VA pictures TCT_VA BLM is further away in comparison with the TCT_H BLM Collimation Working Group #206 27/6/2016 E. Skordis

4 Collimation Working Group #206 27/6/2016
E. Skordis

5 Ion Vaccum Pump VPI-30L E. Skordis
Collimation Working Group #206 27/6/2016

6 Impact at TCTH Collimation Working Group #206 27/6/2016 E. Skordis

7 Impact at TCTV Collimation Working Group #206 27/6/2016 E. Skordis

8 BLM Responses Beam1 Left of IP1
Primary response appears with BOLD Horizontal Impact Parameter: Negative Jaw (closer to BLM): 2.611mm Positive Jaw: 1.234 mm Negative/Positive impacts ~ 5 Horizontal Halo 6.5 TeV BLM response Simulated Collimator BLMTI.B4L1 BLMTI.C4L1 TCTPH.4L1 10.3 1.24 TCTPV.4L1 0.58 4.52 (Values are normalised to the BLM_TCP.C response for horizontal losses at 3.5 TeV which corresponds to Gy/p ) cm configuration Collimator Settings: Primaries: 5.5 σ Secondaries in P7: 6.5 σ Tertiaries in IP1: 9 σ TCTPH: cm TCTPV: cm (halfgap) Vertical Halo 6.5 TeV BLM response Simulated Collimator BLMTI.B4L1 BLMTI.C4L1 TCTPH.4L1 9.36 1.15 TCTPV.4L1 0.6 4.58 Collimation Working Group #206 27/6/2016 E. Skordis

9 Conclusions Updated geometry model with BLM position and addition of the Vacuum pump Illustrated the sensitivity of the BLM response on the geometry and BLM location Simulated the BLM response of TCT BLM response from tertiary halo at 6.5 TeV in Point 1 Results can be used together with the BLM experimental signal in order to calculate the number of protons lost in each collimator properly taking into account the crosstalk effect Thank you! Collimation Working Group #206 27/6/2016 E. Skordis

10 Back up Slide NEW collimator settings/ input
OLD collimator settings/ input Horizontal Impact Parameter: Negative Jaw (closer to BLM): 2.611mm Positive Jaw: 1.234 mm TCTPH: cm (halfgap) Negative/Positive impacts ~ 5 Horizontal Impact Parameter: Negative Jaw (closer to BLM): 0.755mm Positive Jaw: 0.446 mm TCTPH: cm halfgap Negative/Positive impacts ~ 1 Collimation Working Group #206 27/6/2016 E. Skordis