1 LIAISON®: Instrument Overview

2 Contents Highlights Hardware overview User interface Main features
The Diagnostic Specialist Contents Highlights Main features Samples and Reagents Accessories Hardware overview User interface L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

3 LIAISON®: Main features
The Diagnostic Specialist LIAISON®: Main features L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

4 LIAISON®: Main features
“Flash” chemiluminescence detection system Paramagnetic microparticle solid phase Continuous loading of samples and reagents Random access or batch mode 2-point calibration (stability up to 4 weeks) Auto-dilution, auto-reflex, STAT Maximum throughput: ~180 results/h L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

5 LIAISON®: Samples and reagents
The Diagnostic Specialist LIAISON®: Samples and reagents L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

6 Sample management Continuous loading of sample racks
LIAISON®: Samples and reagents Sample management Continuous loading of sample racks On board capability: 144 samples Active opening flap Barcode recognition of racks and samples (compatibility with different tube diameter) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

7 Integral label with barcode
LIAISON®: Samples and reagents Reagents (1) Reagent Integral: typical layout Magnetic Particles Other Reagents Handle Calibrators Holder Aluminum Seals Nose Stirring wheel Integral label with barcode L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

8 Reagents (2) Kit configuration: Reagent Integral
LIAISON®: Samples and reagents Reagents (2) Kit configuration: Reagent Integral mini-CD (IFU, method file) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

9 Reagents (3) On board capability: 15 integrals (1500 tests)
LIAISON®: Samples and reagents Reagents (3) On board capability: 15 integrals (1500 tests) Continuous loading of “reagent integrals” (recognition via barcode) On board refrigerated area (on-board stability up to 8 weeks) Active opening flap L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

10 LIAISON®: Samples and reagents
LIAISON® Controls Characteristics and control run requirements are dependent on assays QC software L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

11 LIAISON® Accessories The Diagnostic Specialist
L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

12 Wash/System Liquid Supplied as concentrated
LIAISON® Accessories Wash/System Liquid Supplied as concentrated 1L  9L with distilled/deionized water Water quality requirement: “NCCLS grade III” Inventory controlled by sensor 1 liter 10 liters L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

13 Starter Reagents Starter 1, Starter 2 Primary bottles on board
LIAISON® Accessories Starter Reagents Starter 1, Starter 2 Primary bottles on board Inventory controlled by sensors L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

14 Reaction modules Continuous loading Inventory controlled by sensors
LIAISON® Accessories Reaction modules Continuous loading 1 reaction module = 6 cavities (6 tests) stacker capacity = 120 reaction modules (720 tests) Inventory controlled by sensors L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

15 Light Check Required for“System Test” “SYSTEM TEST”:
LIAISON® Accessories Light Check Required for“System Test” “SYSTEM TEST”: (daily pre-routine check) Priming Checking of pipetting accuracy and precision Checking of signal background and level L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

16 Solid waste bag Collector of disposed (emptied) Reaction Modules
LIAISON® Accessories Solid waste bag Collector of disposed (emptied) Reaction Modules Level controlled by software counter L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

17 Cleaning Kit CLEAN Tool PUMP Tool
LIAISON® Accessories Cleaning Kit CLEAN Tool For weekly (daily) customer maintenance procedure (automated CLEAN test) PUMP Tool For monthly customer maintenance procedure L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

18 LIAISON®: hardware overview
The Diagnostic Specialist LIAISON®: hardware overview L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

19 Instrument tour LIAISON®: hardware overview
L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

20 Instrument tour Left pipettor Right pipettor 2 pipetting needles
LIAISON®: hardware overview Instrument tour Left pipettor (samples, calibrators) Right pipettor (reagents) 2 pipetting needles (Teflon coated; internal and external programmable wash) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

21 Instrument tour LIAISON®: hardware overview
L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

22 (housing for Reaction Modules)
LIAISON®: hardware overview Instrument tour Stacker (housing for Reaction Modules) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

23 (housing for Starter 1 and Starter 2)
LIAISON®: hardware overview Instrument tour Starter box (housing for Starter 1 and Starter 2) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

24 LIAISON®: hardware overview
Instrument tour Sample area (fits 12 sample racks, each rack has 12 available positions) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

25 Instrument tour Reagent area (15 lanes, refrigerated)
LIAISON®: hardware overview Instrument tour Reagent area (15 lanes, refrigerated) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

26 (3 areas accessible by the pipettors)
LIAISON®: hardware overview Instrument tour Pipetting areas (3 areas accessible by the pipettors) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

27 (for internal/external wash)
LIAISON®: hardware overview Instrument tour Needle wash stations (for internal/external wash) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

28 Incubator (36±1°C, 16 slots, one reaction module each)
LIAISON®: hardware overview Instrument tour Incubator (36±1°C, 16 slots, one reaction module each) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

29 Washer (3 needles, in magnetic field)
LIAISON®: hardware overview Instrument tour Washer (3 needles, in magnetic field) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

30 Measure chamber (Starter injection; measure)
LIAISON®: hardware overview Instrument tour Measure chamber (Starter injection; measure) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

31 (emptied reaction modules)
LIAISON®: hardware overview Instrument tour Solid waste (emptied reaction modules) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

32 Instrument tour Wash/System liquid Wash/System liquid
LIAISON®: hardware overview Instrument tour Wash/System liquid (2x10L, Double tank, sensor-controlled) Wash/System liquid (10L, sensor-controlled) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

33 (10L, sensor-controlled)
LIAISON®: hardware overview Instrument tour Liquid waste (10L, sensor-controlled) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

34 Reaction Modules from stacker to waste
LIAISON®: hardware overview Reaction Modules from stacker to waste Meas. Wash Pip. Inc. Pip. Waste Staker L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

35 LIAISON® User Interface
The Diagnostic Specialist LIAISON® User Interface L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

36 General characteristics
LIAISON®: User Interface General characteristics Touch screen monitor Easy and intuitive menu-structured software Multi-language Sample result traceability (kit info, flags, etc.) Access-right structure Flexible LIS connection L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview

37 References User Manual (multi-language) Quick Guide (multi-language)
LIAISON®: User Interface References User Manual (multi-language) Quick Guide (multi-language) L-CS-304-P (081222) (Rev. A) Liaison - Instrument Overview