Download presentation
Presentation is loading. Please wait.
1
Emory University School of Medicine
Complications of PCI : Perforation Requiring Pericardiocentesis , Device Embolization and Snares SCAI Fall Fellows Course 2012 John S. Douglas Jr. MD Professor of Medicine Emory University School of Medicine
2
Disclosure Statement of Financial Interest
Within the past 12 months, I or my spouse/partner have had a financial interest/arrangement or affiliation with the organization(s) listed below. Affiliation/Financial Relationship Company Consulting Fees/Honoraria None Major Stock Shareholder/Equity None Royalty Income None Ownership/Founder None Intellectual Property Rights None Other Financial Benefit None
3
Complications of Percutaneous Coronary Intervention
Coronary Perforation Stent Misadventures Snares; other retrieval strategies
4
Coronary perforation during PCI in the IIb/IIIa Era
Cleveland Clinic 5,500 Patients; 31% Abciximab; 9 Deaths 24% 30 P=0.02 No Abciximab % Abciximab 6% 1.3 1.5 Perforation Death J Am Coll Cardiol 1999; 33, 72A
5
Coronary Perforation Classification
Type 1 Crater extending outside lumen only Type 2 Pericardial or myocardial blush without > 1mm exit hole Type 3 Contrast jet through > 1mm exit hole Ellis et al. Circulation 1992; 88: I-787
6
Causes of Coronary Perforation During PCI 1995-1999 at Christ Hospital
36 Perforations 15 Odds Ratio Perf. 16 Type 3 Perf. 29 10 Number of Patients 5 Guide Wire Balloon Stent Rotablater DCA Laser/TEC Dippel et al. Cathet Cardiovasc Intervent 2001; 52:
7
Risk associated with Type 3 Perforation
Ellis et al. 1992 Dippel et al. 2001 Tamponade 63% 43% Surgery 75% 50% QMI 29% Death 14% 21%
8
Cardiac Tamponade Complicating PCI – An 8 year experience at William Beaumont Hospital
36 Patients 60 56 44 42 39 % 29 In-Lab Out-of-Lab Surgery MI Death (mean 5 hours) Fejka et al. Circulation 2001; 104: II-417
9
Type III Coronary Perforation : 56 Cases From The Stent Era (1993-2009 )
Incidence : 56 of 24,465 ( 0.23%) Independent predictors were complex lesion , CTO , rotablation , and IVUS guidance Device implicated : balloon 50% , guidewire 18% , atheroablation 7.2% Treatment strategy : balloon 60% , covered stent 46% , coil 1.8% , multiple methods 39% Al-Lamee et al J Am Coll Cardiol Intv 2011;4 :87-95
10
Outcomes Following Type III Perforation
Tamponade & pericardiocentesis in 29% CPR was required in 20% ; IABP in 20% MI ( 3 X CK-MB ) in 43% In – hospital MACE in 55% ; death in 18% Outcomes with GPI were worse (MI 70% , CABG 30% , death 22% and MACE in 90% ) Stent thrombosis in 8.6% of covered stents Al-Lamee et al J Am Coll Cardiol Intv 2011;4 :87-95
11
Small “Stain” Noted on the Inferior Wall During RCA Stent Procedure
Reopro Discontinued
12
Tamponade 3 hrs later: Balloon Occlusion Sealed Perforation Only After Distal Platelet Injection
13
PCI of Chronic Total Occlusion
Difficult Wire Passage
14
Type 3 Perforation Following Inflation of 1.5mm Balloon
15
Type 3 Perforation Treated with Coil Embolization
16
Coronary Perforation - Diagnosis -
Angiographic (blush, jet, coronary sinus compression, contrast in pericardium) No angiographic evidence in 10-20% ECHO (Not needed in 50% at Beaumont) Delayed tamponade common (wire induced & IIbIIIa)
17
Management of Coronary Perforation
Hemodynamic Support Volume and inotropes Pericardiocentesis (pigtail) IABP (to resussitate) Seal Perforation Reverse heparin Balloon occlusion Platelets (abciximab) Embolization (coil, gel foam, thrombus) Covered stent (Jomed available) Surgery
18
Stent Misadventures Imprecise placement
Stent entrapment in uncrossable lesion Unexpandable lesion Sheared off by guide catheter Lost!
19
Common Mechanism of Stent Loss
Stent Entrapment Brilakis et al CCI 2005;66:33
20
Mechanism of Stent Loss
Stent “Pulled-Off” the Delivery Balloon Brilakis et al CCI 2005;66:33
22
Attempt to snare the stent or grasp it with forceps Use twisted wires
What Are The Options ? Insert a balloon into the undeployed stent , inflate it and withdraw the stent out of the coronary Attempt to snare the stent or grasp it with forceps Use twisted wires High risk features in CARESS-IN-AMI: extensive ST elevation, new onset LBBB, previous MI, Killip class >2, or LVEF <35%
23
Retrieval of Stent with Loop Snare
Brilakis et al CCI 2005;66:33
24
Twisted Wire Stent Retrieval
Brilakis et al CCI 2005;66:33
25
Small Balloon Stent Retrieval
Brilakis et al CCI 2005;66:33
26
A 1.5X20 Balloon Was Inserted Inflated ,and Withdrawn
27
A 1.5X20 Balloon Was Inserted Inflated ,and Withdrawn
However the stent could not be pulled out
28
A 1.5X20 Balloon Was Inserted Inflated ,and Withdrawn
And , wire position was suddenly lost
31
What Are The Options Now ?
Leave it in place ? Snare it ? Grasp it with forceps ? Use twisted wires ? High risk features in CARESS-IN-AMI: extensive ST elevation, new onset LBBB, previous MI, Killip class >2, or LVEF <35%
32
Things You May Wish to Consider
Which snare is best ? Shape and size of guide catheter ? Femoral sheath size ? Is imaging optimal ? High risk features in CARESS-IN-AMI: extensive ST elevation, new onset LBBB, previous MI, Killip class >2, or LVEF <35%
33
Retrieval Devices Brilakis et al CCI 2005;66:33
41
Final RCA Result
42
Stent Embolization Systemically – generally “safe” Intracoronary
Deploy (if on wire) Crush (if off wire) Retrieve with snare or wrapped in parallel guide wires or on small balloon
43
Mayo Clinic Experience 11,773 PCI’s
● Stent loss in 0.32% ● Successful retrieval 35/38 - balloon expansion and withdrawal 45% - snare 26% - twisted wires 5% - forceps 12% Brilakis et al CCI 2005;66:33
44
Conclusion Complications of PCI have decreased with routine use of intracoronary stents However, perforation and stent misadventures continue to challenge the interventionalist. Attention to prevention, recognition and treatment of these complications is essential
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.