Percutaneous Closure of an Aortic Prosthetic Paravalvar Leak: An Australian First
Jonathon P. Fanning, MBBS, Stephen V. Cox, FRACP, Gregory M. Scalia, FRCC, FRACP, FASE Heart, Lung and Circulation Volume 21, Issue 3, Pages (March 2012) DOI: /j.hlc Copyright © 2011 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ) Terms and Conditions
2
Figure 1 Panel A: Angiographic imaging of the paravalvar defect closure device (black arrow) adjacent to the aortic prosthesis. The orientation of the devices is demonstrated in the inset panel. Panel B: Omniplane transoesophageal echocardiographic imaging of the paravalvar defect closure device (white arrow) adjacent to the aortic prosthesis (Ao: aorta; LA: left atrium; LV: left ventricle). Heart, Lung and Circulation , DOI: ( /j.hlc ) Copyright © 2011 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ) Terms and Conditions
3
Figure 2 Panel A: Transthoracic apical four chamber view demonstrating the jet of severe aortic regurgitation (white arrows) into the left ventricle (LV: left ventricle; LA: left atrium). Panel B: Post-implant apical echocardiographic view showing trivial residual aortic regurgitation (white arrow). Heart, Lung and Circulation , DOI: ( /j.hlc ) Copyright © 2011 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ) Terms and Conditions
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.