Download presentation
Presentation is loading. Please wait.
1
EXO-SKELETON Hamed kalami (PhD Student)
Andre Khayat (Bachelors Degree) Supervisor: Dr. Urbanic
2
CONTENTS What is Ehlers–Danlos Syndrome (EDS) Signs and symptoms
Problem to be Solved and Goal Bones and joints of hand Parametric dimensions of Hand Previous Designs Designs and Models Parametric Design Measuring System Future Measuring System Materials
3
Ehlers–Danlos SyndromeSigns and symptoms
Overly flexible joints - Because the connective tissue that holds joints together is looser, your joints can move far past the normal range of motion. Stretchy skin - Weakened connective tissue allows your skin to stretch much more than usual. Fragile skin - Damaged skin often doesn't heal well
4
Figure 21 Standard Bulky, Cumbersome, Poorly Sized Brace
Problem to be Solved Bypass the tedious and costly procedures currently in place for EDS braces Waiting period Poorly fitted braces Insurance coverage issues No currently designed brace for many joints Less costly braces More customized Figure 21 Standard Bulky, Cumbersome, Poorly Sized Brace
5
Bones and joints of hand
Bones of the right hand Joints of the right hand Metacarpal phalangeal Joint
6
Parametric dimensions of Hand
Proximal Middle Distal Thumb 0.196 ∗ H L lI −2 – 0.158 ∗ H L lI −3 Index 0.265 ∗ H L lI I −2 0.143 ∗ H L I I −3 0.097 ∗ H L lI I −4 0.277 ∗ H L lI I I −2 0.170 ∗ H L I I I −3 0.108 ∗ H L lI I I −4 Ring 0.259 ∗ H L lI V −2 0.165 ∗ H L I V −3 0.107 ∗ H L lI V −4 Small 0.206 ∗ H L lV −2 0.117 ∗ H L V −3 0.093 ∗ H L lV −4 Parametric length for a hand Metacarpal bones Thumb 0.251 ∗ H L lI −1 Index (0.374 ∗ H L)2 + (0.126 ∗ H B)2 lI I −1 Middle 0.373 ∗ H L lI I I −1 Ring (0.336 ∗ H L)2 + (0.077 ∗ H B)2 lI V −1 Small (0.295 ∗ H L)2 + (0.179 ∗ H B)2 lV −1 Parametric length for a finger Parametric length for a thumb
7
PREVIOUS DESIGNS
8
Designs and Models Casing Design Brace Design Pillbug Design
Whole Hand Brace
9
Casing design Simple design 2 parts Functional
Easy to make it aesthetic No pinching
10
Brace Design Curves are fit on the finger Parametric design Aesthetic
Light Hinge for DIP and static for PIP Simple mechanism
11
Pill bug (Accordion) design
12
Models for Whole Hand
13
Parametric Design
14
Measuring System Point cloud Sophisticated surfaces Needs steady part
Takes time to scan
15
Future Measuring System
Structured-light 3D scanner Scanning whole the surface in one time Quick Not effected by object movement Point cloud to polygon software Very fast Automated accurate
16
Materials Material Cost/Kg (USD) Pro Con Extruder Temp (°C)
Application ABS $29.00 Availability, ease of use, affordability Hardness, roughness Stiff, non-movable parts, Ninjaflex $110.00 Flexible, Retains Shape after Deformation Complex Printing Phone Cases Nylon $57.30 Flexible when thin, High Tensile Strength, Lightweight Complex process, High Price Printed Gears TPU $104.80 Flexibility, Elasticity, Chemical Resistance Difficulty Maintaining Stiffness/Shape, High Price Medical Devices
17
Stair Assist Robust Frames Load-Bearing Components
Large-scale, intricate profiles Multi-Material and Multi-Process Interface
18
Stair Assist Prototype CAD Model
Individual components modeled in Catia V5 Brought together in common assembly Frame padded out from behind Complete Model of Prototype obtained
19
Stair Assist Prototype Manufactured Model
Individual components dissected into printable/machineable parts based on necessary mechanical properties Entire assembly brought together into functional prototype employing various manufacturing methods seamlessly
20
Other Designs
21
Thank You
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.