1
Comparison of Neck Screw and Conventional Fixation Techniques in Mandibular Condyle Fractures Using 3-Dimensional Finite Element Analysis Ricardo Augusto Conci, Flavio Henrique Silveira Tomazi, Pedro Yoshito Noritomi, PhD, Jorge Vicente Lopes da Silva, PhD, Guilherme Genehr Fritscher, PhD, Claiton Heitz, PhD Journal of Oral and Maxillofacial Surgery Volume 73, Issue 7, Pages (July 2015) DOI: /j.joms Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
2
Figure 1 (A) One-miniplate system. (B) Two-miniplate system. (C) System using neck screw and “L”-shaped plate. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
3
Figure 1 (A) One-miniplate system. (B) Two-miniplate system. (C) System using neck screw and “L”-shaped plate. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
4
Figure 2 (A) Displacement values in 1-miniplate system. (B) Displacement values in 2-miniplate system. (C) Displacement values in neck screw system. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
5
Figure 2 (A) Displacement values in 1-miniplate system. (B) Displacement values in 2-miniplate system. (C) Displacement values in neck screw system. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
6
Figure 3 (A) Von Misses tension values for 1-miniplate system. (B) Von Misses tension values for 2-miniplate system. (C) Von Misses tension values for neck screw system. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
7
Figure 4 (A) Main maximum tension values for 1-miniplate system. (B) Main maximum tension values for 2-miniplate system. (C) Main maximum tension values for neck screw system. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions
8
Figure 5 (A) Main minimum tension values for 1-miniplate system. (B) Main minimum tension values for 2-miniplate system. (C) Main minimum tension values for neck screw system. Journal of Oral and Maxillofacial Surgery , DOI: ( /j.joms ) Copyright © 2015 American Association of Oral and Maxillofacial Surgeons Terms and Conditions