Presentation is loading. Please wait.

Presentation is loading. Please wait.

Validation of smart textile electrodes for electrocardiogram monitoring in free-moving horses  Andrea Guidi, Antonio Lanata, Gaetano Valenza, Enzo Pasquale.

Similar presentations


Presentation on theme: "Validation of smart textile electrodes for electrocardiogram monitoring in free-moving horses  Andrea Guidi, Antonio Lanata, Gaetano Valenza, Enzo Pasquale."— Presentation transcript:

1 Validation of smart textile electrodes for electrocardiogram monitoring in free-moving horses 
Andrea Guidi, Antonio Lanata, Gaetano Valenza, Enzo Pasquale Scilingo, Paolo Baragli  Journal of Veterinary Behavior: Clinical Applications and Research  Volume 17, Pages (January 2017) DOI: /j.jveb Copyright © 2016 Elsevier Inc. Terms and Conditions

2 Figure 1 Experimental set up: placement of systems with the smart textiles and Ag/AgCl electrodes (a) and the phone interface (b). Journal of Veterinary Behavior: Clinical Applications and Research  , 19-23DOI: ( /j.jveb ) Copyright © 2016 Elsevier Inc. Terms and Conditions

3 Figure 2 Examples of ECG traces recorded with smart textiles (red) and Ag/AgCl (blue) electrodes. In the Ag/AgCl-based recording, high-amplitude peaks are shown in the trace, which are generated by MAs and can be confused with the R peaks. The real R peaks collected with Ag/AgCl electrodes have smaller amplitudes. (For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.) Journal of Veterinary Behavior: Clinical Applications and Research  , 19-23DOI: ( /j.jveb ) Copyright © 2016 Elsevier Inc. Terms and Conditions

4 Figure 3 The number of MAs over time recorded for each of the 7 horses. In the histograms, the reported values relate to the signal sample. A signal sampled at 250 Hz has 250 samples/s. Given that an artifact is identified with a piece of altered signal, the number of the samples included in each artifact (y axis) for each bin (x axis) has been counted. Journal of Veterinary Behavior: Clinical Applications and Research  , 19-23DOI: ( /j.jveb ) Copyright © 2016 Elsevier Inc. Terms and Conditions

5 Figure 4 Boxplot of MA% obtained from Ag/AgCl and textile electrodes.
Journal of Veterinary Behavior: Clinical Applications and Research  , 19-23DOI: ( /j.jveb ) Copyright © 2016 Elsevier Inc. Terms and Conditions


Download ppt "Validation of smart textile electrodes for electrocardiogram monitoring in free-moving horses  Andrea Guidi, Antonio Lanata, Gaetano Valenza, Enzo Pasquale."

Similar presentations


Ads by Google