Presentation is loading. Please wait.

Presentation is loading. Please wait.

Real time Pcr.

Similar presentations


Presentation on theme: "Real time Pcr."— Presentation transcript:

1 Real time Pcr

2 Limitations of End-Point PCR
Poor Precision Low sensitivity Low resolution Non - Automated Size-based discrimination only Results are not expressed as numbers Ethidium bromide for staining is not very quantitative Post PCR processing

3 The Evolution of PCR to Real-Time
Traditional PCRs use Agarose gels for detection of amplification at the final phase or end-point of the PCR reaction Real time PCR has advanced to allow detection before the end-point of the reaction.

4 Real-time PCR detection
While the reaction is occurring monitors the fluorescence emitted during the reaction as an indicator of amplicon production at each PCR cycle Real-Time chemistries allow for the detection of PCR amplification during the early phases of the reaction

5

6 PCR Phases Exponential: Linear (High Variability):
Exact doubling of product is accumulating at every cycle (assuming 100% reaction efficiency). The reaction is very specific and precise. Linear (High Variability): The reaction components are being consumed, the reaction is slowing, and products are starting to degrade. Plateau (End-Point: Gel detection for traditional methods): The reaction has stopped, no more products are being made and if left long enough, the PCR products will begin to degrade. Figure 3 shows three replicates of a sample. The replicates have the same starting quantity. As the PCR reaction progresses, the samples begin to amplify in a very precise manner. Amplification occurs exponentially, that is a doubling of product (amplicon) occurs every cycle. This type of amplification occurs in the exponential phase. Exponential amplification occurs because all of the reagents are fresh and available, the kinetics of the reaction push the reaction to favor doubling of amplicon. However, as the reaction progresses, some of the reagents are being consumed as a result of amplification. This depletion will occur at different rates for each replicate. The reactions start to slow down and the PCR product is no longer being doubled at each cycle. This linear amplification can be seen in the linear phase of the reaction. The three samples begin to diverge in their quantities during the linear phase. Eventually the reactions begin to slow down and stop all together or plateau. Each tube or reaction will plateau at a different point, due to the different reaction kinetics for each sample. These differences can be seen in the plateau phase. The plateau phase is where traditional PCR takes its measurement, also known as end-point detection. Figure 3 also shows that the three replicate samples, which started out at the same quantity in the beginning of the reaction, reflect different quantities at the plateau phase. Since the samples are replicates they should have identical quantities. Therefore, it will be more precise to take measurements during the exponential phase, where the replicate samples are amplifying exponentially. The amplification phases can be viewed differently to assess the PCR phases. The figures that follow show the phases of PCR in a Logarithmic scale view and a Linear scale view (Figures 4 and 5).

7

8 The plateau effect on a fivefold dilution series:
The 5-fold dilution series, seems to plateau at the same place even though the exponential phase clearly shows a difference between the points along the dilution series. This reinforces the fact that if measurements were taken at the plateau phase, the data would not truly represent the initial amounts of starting target material. As you can see from the figure, the samples in the gel contain 10 copies and 50 copies, respectively. It is hard to differentiate between the 5-fold change on the Agarose gel. Real-Time PCR is able to detect a two-fold change (i.e. 10 Vs. 20 copies) .

9 Real-time Principles Three general methods for the quantitative detection: Hydrolysis probes (TaqMan, Beacons). Hybridisation probes (Light Cycler). DNA-binding agents (SYBR Green).

10 TaqMan Chemistry Real-time systems using fluorogenic-labeled probes that use the 5´ nuclease activity of Taq DNA polymerase. Detecting only specific amplification products. Eliminate post-PCR processing for the analysis of probe degradation

11 A fluorogenic probe enables the detection of a specific PCR product as it accumulates during PCR.
The TaqMan® Probe is designed with a high-energy dye termed a Reporter at the 5 end, and a low-energy molecule termed a Quencher at the 3 end. While the probe is intact, the proximity of the quencher dye greatly reduces the fluorescence emitted by the reporter dye by fluorescence resonance energy transfer (FRET) through space. When reporter and quencher are separated the reporter fluoroscence

12 How TaqMan Sequence Detection Chemistry Works
If the target sequence is present, the probe anneals downstream from one of the primer sites During extension the probe is cleaved by the 5´ nuclease activity of Taq DNA polymerase. The reporter dye is separated from the quencher dye, increasing the reporter dye signal. The probe is removed from the target strand, allowing primer extension to continue to the end of the template strand.. Additional reporter dye molecules are cleaved from their respective probes with each cycle. Hydrolysis probe technique: The hydrolysis probe is conjugated with a quencher fluorochrome, which absorbs the fluorescence of the reporter fluorochrome as long as the probe is intact. However, upon amplification of the target sequence, the hydrolysis probe is displaced and subsequently hydrolyzed by the Taq polymerase. This results in the separation of the reporter and quencher fluorochrome and consequently the fluorescence of the reporter fluorochrome becomes detectable. During each consecutive PCR cycle this fluorescence will further increase because of the progressive and exponential accumulation of free reporter fluorochromes.

13 The fluorescence intensity is increased proportional to the amount of amplicon produced.

14 Molecular Beacons

15 Hybridization Probes Fluorescence Resonance Energy Transfer (FRET) Concept Donor fluorophore is excited by appropriate wavelength Donor energy is transferred non-radiatively to the acceptor fluorophore Excited acceptor emits at longer wavelength Increase in fluorescence with each cycle The signal depends only on hybridization

16 How the Hybridisation probes work?
When the two fluorochromes are in close vicinity (1–5 nucleotides apart), the emitted light of the donor fluorochrome will excite the acceptor fluorochrome (FRET). This results in the emission of fluorescence, which subsequently can be detected during the annealing phase and first part of the extension phase of the PCR reaction. Hybridisation probes technique: In this technique one probe is labelled with a donor fluorochrome at the 3’ end and a second –adjacent- probe is labelled with an acceptor fluorochrome. When the two fluorochromes are in close vicinity (1–5 nucleotides apart), the emitted light of the donor fluorochrome will excite the acceptor fluorochrome (FRET). This results in the emission of fluorescence, which subsequently can be detected during the annealing phase and first part of the extension phase of the PCR reaction. After each subsequent PCR cycle more hybridisation probes can anneal, resulting in higher fluorescence signals.

17 SYBR® Green I Dye Chemistry
Small molecules that bind to double- stranded DNA can be divided into two classes: Intercalators Minor-groove binders There are two requirements for a DNA binding dye for real-time detection of PCR: Increased fluorescence when bound to double-stranded DNA No inhibition of PCR

18 How the SYBR Green I Dye Chemistry Works
When SYBR Green I dye is added to a sample, it immediately binds to all double-stranded DNA present in the sample. During the PCR, the DNA Polymerase amplifies the target sequence, and creates the PCR products. The SYBR Green I dye binds to each new copy of double-stranded DNA. As the PCR progresses, more amplicons are created. The result is an increase in fluorescence intensity proportionate to the amount of PCR product produced. SYBR Green I technique: SYBR Green I fluorescence is enormously increased upon binding to double-stranded DNA. During the extension phase, more and more SYBR Green I will bind to the PCR product , resulting in an increased fluorescence. Consequently, during each subsequent PCR cycle more fluorescence signal will be detected.

19 Advantages of SYBR Green I Dye
It can be used to monitor the amplification of any double-stranded DNA sequence. No probe is required, which reduces assay setup and running costs. Disadvantage of SYBR Green I Dye SYBR Green I dye chemistry may generate false positive signals SYBR Green I dye binds to nonspecific double-stranded DNA sequences. Needs fully optimized PCR system -no primer dimers or non-specific amplicons. When not to choose SYBR Green Multiplex reactions.

20 Terms Used in Quantitation Analysis
Amplification plot: The plot of fluorescence signal versus cycle number

21 Baseline: The initial cycles of PCR, in which there is little change in fluorescence signal
Passive reference: A dye that provides an internal reference to which the reporter dye signal can be normalized during data analysis. Rn (normalized reporter): The fluorescence emission intensity of the reporter dye divided by the fluorescence emission intensity of the passive reference dye. Normalization is necessary to correct for fluctuations caused by changes in concentration or volume.

22 Rn+: The Rn value of a reaction containing all components, including the template
Rn-:The Rn value of an un-reacted sample. The Rn-value can be obtained from: The early cycles of a real-time PCR run (those cycles prior to a detectable increase in fluorescence), OR A reaction that does not contain any template ΔRn (delta Rn): The magnitude of the signal generated by the given set of PCR conditions. [ΔRn = (Rn+) – (Rn-)]

23 Threshold: The average standard deviation of Rn for the early PCR cycles, multiplied by an adjustable factor. The threshold should be set in the region associated with an exponential growth of PCR product. Ct (threshold cycle): The fractional cycle number at which the fluorescence passes the fixed threshold

24

25 Quantitation By Real time PCR

26 Absolute Quantitation
Used to quantitate unknown samples by interpolating their quantity from a standard curve. Standard: A sample of known concentration used to construct a standard curve. From a standard curve you can extrapolate the quantity of an unknown sample. Unknown: A sample containing an unknown quantity of template. This is the sample whose quantity you want to determine

27

28 The standard curve resulting from Ct value and standard concentrations should be a linear graph with a high correlation coefficient (> 0.99). Theoretically a single copy of the target should create a CT value of 40 (if efficiency is 100%), which is the y-intercept in a standard curve experiment CT value of 40 or more means no amplification and cannot be included in the calculations

29 Relative Quantitation
A relative quantitation assay is used to analyze changes in gene expression in a given sample relative to another reference sample (such as an untreated control sample). Relative quantitation might be used to measure gene expression in response to a chemical (drug).

30 Relative Quantitation Standard curve method
Using a separate standard curve for the target and endogenous control, in separate tubes. Requires the least amount of optimization and validation.

31 Relative Quantitation Comparative CT method
The need for a standard curve is eliminated. The target and endogenous control are amplified in the same tube. Increased throughput: wells no longer need to be used for the standard curve samples. the adverse effect of any pipetting and dilution errors made in creating the standard curve samples are eliminated. A validation experiment must be run to show that the efficiencies of the target and endogenous control amplifications are approximately equal.

32 Endogenous/Internal Control
Usually an abundantly and constantly expressed housekeeping gene Best to run a validity test for the selected endogenous control Combination may be used

33 Understanding CT CT (threshold cycle) is the intersection between an amplification curve and a threshold line. It is a relative measure of the concentration of target in the PCR reaction. The CT values from PCR reactions run under different conditions or with different reagents cannot be compared directly. A: Rn is the fluorescence of the reporter dye divided by the fluorescence of a passive reference dye. In other words, Rn is the reporter signal normalized to the fluorescence signal of ROX™. In this view, Rn is graphed versus cycle. B: ΔRn is Rn minus the baseline, graphed here versus the cycle of PCR. C: Amplification plot shows the Log (ΔRn) graphed versus cycle.

34 Effect of Efficiency of a PCR Reaction on Ct
The slope of a standard curve is a reflection of the amplification efficiency The efficiency of the reaction can be calculated by the following equation: Eff=10(-1/slope) –1 The efficiency of the PCR should be % (ideal slope = ­3.32) The PCR efficiency is dependent on: the assay and the master mix performance sample quality. length of the amplicon secondary structure primer design

35

36 Using the PCR Equation Xn = X0(1 + E)n Xn X0
Xn = PCR product after cycle n X0 = initial copy number E = amplification efficiency n = cycle number Xn E IS MAXIMALLY 1.0, BUT USUALLY AROUND 0.9. X0 cycle number 36

37 Effect of Amplification Efficiency
Xn = X0(1+E)n Case 1: E = Case 2: E = 0.8 Xn = 100 (1+0.9)30 Xn = 100 (1+0.8)30 Xn = 2.3 x 1010 Xn = 4.6 x 109 CALCULATE EFFICIENCIES FROM THE SLOPE OF YOUR DOSE RESPONSE CURVES Result A difference of 0.1 in amplification efficiencies created a five-fold difference in the final ratio of PCR products after 30 cycles 37

38 Applications of Molecular Based Testing in Clinical Microbiology
Rapid or high-throughput identification of microorganisms Those that are difficult or time-consuming to isolate e.g., Mycobacteria Hazardous organisms e.g., Histoplasma, Coccidiodes Those without reliable testing methods e.g., HIV, HCV High-volume tests e.g., S. pyogenes, N. gonorrhoeae, C. trachomatis

39 Applications of Molecular Based Testing in Clinical Microbiology
Detection and analysis of resistance genes mecA  oxacillin resistance in Staphylococcus aureus vanA, vanB, and vanC  vancomycin resistance in Enterococcus katG and inhA  isoniazid resistance in M. tuberculosis Genotyping Mycobacterium, HCV, and HIV Reclassification of microorganisms for epidemiological purposes, and to predict therapeutic efficacy Discovery of new microorganisms

40 Real-time PCR advantages
Not influenced by non-specific amplification Amplification can be monitored in real-time No post-PCR processing of products (high throughput, low contamination risk) Ultra-rapid cycling (30 minutes to 2 hours) Most specific, sensitive and reproducible Not much more expensive than conventional PCR (except equipment cost)


Download ppt "Real time Pcr."

Similar presentations


Ads by Google