Download presentation
Presentation is loading. Please wait.
Published byPenelope Cummings Modified over 6 years ago
1
Stephan Aulenbacher MAGIX Collaboration Meeting 2017-02-16
The Stephan Aulenbacher MAGIX Collaboration Meeting
2
Topics A1 Boundaries The Chamber The Catcher Rearrangement of A1
Summary
3
Motivation Target walls causing the major contributions to the background!
4
Boundaries from A1 Parameters: 510 mm diameter of the chamber
Hight of the windows at least 160 mm Window on 90 degree on both sides for adjustment 15 degree smallest angle in forward direction Biggest possible opening angle for the windows Opening of the exit beamline 35 mm
5
Boundaries from the Target
Parameters: DN 320 ISO K Flange for the main connection DN 200 CF Flange on the sinde for a turbo pump Catcher and Nozzle must be adjustable
6
The Catcher/Injection
Catcher position Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil
7
Bellow to pump connection
The Catcher Catcher position Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Beamline Groundplate Bellow to pump connection
8
The Catcher Catcher position Nozzle position Beam
Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Pipe to catcher
9
Adjustment of the whole structure throug movement of the bottom
The Catcher Catcher position Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Actual catcher Adjustment of the whole structure throug movement of the bottom
10
The Catcher Catcher position Nozzle position Beam
Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Injection Nozzle
11
The Catcher Catcher position Nozzle position Beam
Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Adjustment
12
The Catcher Catcher position Nozzle position Beam
Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Revolver
13
The Catcher Catcher position Nozzle position Beam
Adjustable in x-y-z Direction Nozzle position Beam Adjustment Carbon foil Chamber
14
The Chamber Geometry Windows Turbo pump 510 mm diameter
35 mm exit beamline Windows 90 degree for adjustment 15 degree angle in forward direction Biggest possible opening 160 mm height Turbo pump DN 200 CF Flange
15
Rearrangement of A1 Exchange the chamber
Exchange the chamber‘s platform Place the pumping station Place the control rack in the bunker Electricity support, cooling water, liquid nitrogen,…
16
Rearrangement of A1 Range of Spec A Space for Turbopump Pumps
Similar presentations