Introduction Multiple factors influence the choice of both adhesive and release liner End user requirements Converting, die cutting Printing, dispensing, application Adhesive characteristics Liner characteristics Components are impacted by one another Overall objective is to deliver a label that end user can dispense efficiently Release Study: Consider adhesive factors which contribute to release changes: Tackifier chemistry Rubber/Elastomer types Rheology Case Study: application of study results September 2013 Label Release Liner Industry Seminar
4
STUDY PARAMETERS Evaluation using single UV cured silicone release formulation. Optimization for obtain easy release Evaluation of 10 Hot Melt adhesives of varying chemistries Sample Preparation: Single UV cured silicone formulation, single coating incidence Test adhesives coated to liner via ChemInstruments HLC-100 Facestock 20# DP Bond, laminated in line. September 2013 Label Release Liner Industry Seminar
5
Test Conditions All release testing done on IMASS ZPE1100W hi/variable speed release tester. Ramped Velocity: 0-2 meters per second, references force at 1200 ipm (0.508 m/s) Constant Speed testing at 1200 ipm. Samples listed A through J lowest to highest based on G” as per Rheometrics RDAIII temperature sweep. September 2013 Label Release Liner Industry Seminar
6
Rheology plots Highest G” Lowest G” September 2013
Label Release Liner Industry Seminar
7
ADHESIVES EVALUATED September 2013
Label Release Liner Industry Seminar
8
Sample ordering based on Loss Modulus G”
September 2013 Label Release Liner Industry Seminar
9
Release force 0.508 m/s ramped velocity test. (1200 ipm value)
September 2013 Label Release Liner Industry Seminar
10
Constant speed release, 1200 ipm
September 2013 Label Release Liner Industry Seminar
11
Release force by G” and Tackifier
September 2013 Label Release Liner Industry Seminar
12
Release force by G” and Polymer
September 2013 Label Release Liner Industry Seminar
13
Ramped Force Separated by Polymer type
September 2013 Label Release Liner Industry Seminar
14
SUMMARY Study looked at holding silicone chemistry constant and evaluating release force of various adhesives Adhesives were characterized by three parameters: rheology, tackifier chemistry and rubber type Looked at release values at constant speed as well as ramped velocity September 2013 Label Release Liner Industry Seminar
15
Conclusions Data suggest a strong inverse correlation between G” and release force values Lower release force is required for higher G” formulations (“stiffer” adhesives”) Within the samples evaluated There did not seem to be an effect of tackifier chemistry – hydrocarbon or rosin ester Rubber type also was not seen to correlate to release force Release performance requirements need to be considered during adhesive formulation as well as silicone selection So how can this information be applied to adhesive development? September 2013 Label Release Liner Industry Seminar
16
Case History: Applying study learnings
Background: Launched a new freezer grade adhesive Customer reported release issues: too tight for auto-dispensing Approach Apply learnings from the study to modify release New formula: changes to both rubber and tackifier No significant impact on performance (peel/tack) Maintained cold temperature adhesion Release values now within acceptable range September 2013 Label Release Liner Industry Seminar
17
Rheology : new versus original
September 2013 Label Release Liner Industry Seminar
18
Release Force Charts Original Adhesive Modified Adhesive
Release force values at 1200 in/min Original grams/in Modified grams/in September 2013 Label Release Liner Industry Seminar
19
Conclusions Data of study suggested a strong inverse correlation between G” and release force values Lower release force is required for higher G” formulations (“stiffer” adhesives”) Release performance requirements need to be considered during adhesive formulation as well as silicone selection Case Study showed how the study findings can be applied Balance performance needs with release requirements September 2013 Label Release Liner Industry Seminar