Download presentation
Presentation is loading. Please wait.
1
DUAL TEMPERATURE SYSTEM
HWASUNG THERMO CO., LTD.
2
HT-250SPES DTS 12 x 7 x 7ft Condenser Evaporator 1 Evaporator 2
-25℃ 0℃ Cond. Eva. 1 Eva. 2 Condenser Evaporator 1 Evaporator 2 HT-250SPES HT-100 II HT-050 II
3
HT-30DWES DTS 16 x 7 x 7ft Condenser Evaporator 1 Evaporator 2
-25℃ 0℃ Cond. Eva. 1 Eva. 2 Condenser Evaporator 1 Evaporator 2 HT-30DWES HT-250 II HT-100 II
4
HT-50DWES DTS 20 x 7.5 x 7.5ft Condenser Evaporator 1 Evaporator 2
-25℃ 0℃ Cond. Eva. 1 Eva. 2 Condenser Evaporator 1 Evaporator 2 HT-50DWES HT-250 II
5
PRODUCT HT-50DWES DTS
7
Set Temperature -25℃ ( Normal Drive Mode)
COMPARTMENT 1 – TEMP.A Set Temperature -25℃ ( Normal Drive Mode) ◀ High Speed Until temperature get -25℃ ◀ Low Speed When temperature reaches at -25℃ ◀ Defrost starts When temperature lower than -25℃
8
Set Temperature 0℃ ( Normal Drive Mode)
COMPARTMENT 2 – TEMP.B Set Temperature 0℃ ( Normal Drive Mode) ◀ B.Co On Second Evaporator is running until temperature get 0℃ ◀ B.Co off Evaporator fan stops when temp. reaches at set-point