Fujitsu Training Documentation Hardware Installation
Hardware Installation ETERNUS DX500 S3 and DX600 S3 ETERNUS DX500 S3 and DX600 S3 Hardware Installation Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
2
Fujitsu Training Documentation
Hardware Installation ETERNUS DX500 S3 and DX600 S3 Content Rack Mounting Power Cabling DX500 S3 / DX600 S3 Backend Architecture Backend Cabling QSFP Power On / Power Off Procedures CE Switch Panel - Function Buttons Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
3
Fujitsu Training Documentation
Rack Mounting Hardware Installation ETERNUS DX500 S3 and DX600 S3 Fit the Controller Enclosure and/or Drive Enclosure to the rack For more and detailed information use the Hardware Installation Guide for the ETERNUS DX Midrange S3; inp-R14B EN1) For better stability installation of hardware in a rack has to start from the bottom Always have tilt prevention in place when installing HD-DE Make sure in advance that the maximum load capacity of the raised floor construction is not exceeded when installing High Density Drive Enclosures (that can be extremely heavy when fully populated) Controller Enclosure: maximum 54 kg Drive Enclosure: maximum 35 kg HD Drive Enclosure: maximum 95 kg 1) At the end of the file name 01 refers to first released version and EN refers to language variant English Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
4
Fujitsu Training Documentation
Power Cabling Hardware Installation ETERNUS DX500 S3 and DX600 S3 For FTS (CEMEA&I) only Connect the rack PDUs (Power Distribution Units) to independent AC power phases Make sure that the AC power switches on each Enclosure are turned off before connecting their power cables Connect each Power Supply of an Enclosure to different Power Distribution Units Left Rack PDU Right Rack PDU PSU#0 inlet PSU#1 inlet Always follow the local power cabling regulations! PSU#0 inlet PSU#1 inlet Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
5
DX500 S3 Backend Architecture
Fujitsu Training Documentation DX500 S3 Backend Architecture Hardware Installation ETERNUS DX500 S3 and DX600 S3 Diskless Controller Enclosure 2x PCIe 3.0 links used as CM inter-communication paths 1x IOC (SAS I/O Controller) per CM Redundant paths to DEs 1x SAS-3.0 Expander per CM Provides 2x independent SAS bus connectors Each SAS backend pair supports maximum of 11 DEs SAS QSFP cable (external) 2 backend SAS pairs Each port supports SAS 12G 4 parallel SAS lines BUD Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
6
DX600 S3 Backend Architecture
Fujitsu Training Documentation DX600 S3 Backend Architecture Hardware Installation ETERNUS DX500 S3 and DX600 S3 Diskless Controller Enclosure 2x PCIe 3.0 links used as CM inter-communication paths 2x IOC (SAS I/O Controller) per CM Redundant paths to DEs 1x SAS-3.0 Expander per CM Provides 4x independent SAS bus connectors Each SAS backend pair supports maximum of 11 DEs SAS QSFP cable (external) 4 backend SAS pairs Each port supports SAS 12G 4 parallel SAS lines BUD Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
7
Fujitsu Training Documentation
SAS Backend Cable QSFP Hardware Installation ETERNUS DX500 S3 and DX600 S3 Follow the SAS port labels at the Enclosures This will point to the correct cabling This sign means "IN" and this sign means "OUT" Connect the cables according the labels showing the direction Cable end marked with plug into Enclosure connector marked with SAS ports of the Controller Enclosure always have the type "OUT" QSFP Cable Is a twin-cable with a Mini SAS connector at its end The cable has a blue release tab that must be applied when removing the cable from the connector Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
8
DX500 S3 Backend Cabling QSFP (1)
Fujitsu Training Documentation DX500 S3 Backend Cabling QSFP (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Drive Enclosure expansion Connect SAS (OUT) ports with SAS (IN) ports 2 ports (2 paths) are provided for SAS (OUT) per CM IN OUT IN OUT Drive Enclosure# 10 IN OUT IN OUT Drive Enclosure #00 C M # 1 Controller Enclosure C M # 0 SAS Port # 0 SAS Port # 1 SAS Port # 0 # 1 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
9
DX500 S3 Backend Cabling QSFP (2)
Fujitsu Training Documentation DX500 S3 Backend Cabling QSFP (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 QSFP cables in lengths 3.5 m and 6 m are available for forward and reverse cabling DX 500 S3 supports up to 11 DEs per each (2) SAS bus 2nd DE must be connected to the second SAS bus DE#12 OUT IN DE#02 OUT IN DE#11 OUT IN DE#01 OUT IN DE#10 OUT IN DE#00 OUT IN IOM#0 IOM#1 #1 #0 CE DX500 S3 CM#0 CM#1 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
10
DX600 S3 Backend Cabling QSFP (1)
Fujitsu Training Documentation DX600 S3 Backend Cabling QSFP (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Drive Enclosure expansion Connect SAS (OUT) ports with SAS (IN) ports 4 ports (4 paths) are provided for SAS (OUT) per CM IN OUT IN OUT Drive enclosure 30 IN OUT IN OUT Drive enclosure 20 IN OUT IN OUT Drive enclosure 10 IN OUT IN OUT Drive enclosure 00 Controller enclosure #0 #1 SAS Port #2 #3 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
11
DX600 S3 Backend Cabling QSFP (2)
Fujitsu Training Documentation DX600 S3 Backend Cabling QSFP (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 QSFP cables in lengths 3.5 m and 6 m are available for forward and reverse cabling DX 600 S3 supports up to 11 DEs per each (4) SAS bus All SAS buses must be populated before adding a second DE to the first bus Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
12
Advantage of Reverse QSFP Cabling
Fujitsu Training Documentation Advantage of Reverse QSFP Cabling Hardware Installation ETERNUS DX500 S3 and DX600 S3 In the extremely rare case of a complete DE failure all HDDs remain accessible in all surviving DEs No longer accessible Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
13
DX Midrange S3 HD-DE Expansion
Fujitsu Training Documentation DX Midrange S3 HD-DE Expansion Hardware Installation ETERNUS DX500 S3 and DX600 S3 Maximum number of HD-DEs DX500 S3 8 when the total number of HDDs does not exceed 528 16 when the total number of HDDs does not exceed 1056 DX500 S3 DX600 S3 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
14
Fujitsu Training Documentation
Power On Procedure (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 The ETERNUS DX S3 systems can be powered on from the Controller Enclosure Push the Power Switch The Power Switch of the CE lights green The power on sequence takes about 2 minutes If everything is OK, the green Ready LED in the CE and the green Power LED in the DE switch on ID Fault Power Power Ready Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
15
Fujitsu Training Documentation
Power On Procedure (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Controller Enclosure LEDs POWER SWITCH with integrated LED Constant green when the power is turned on READY LED Constant green when device is available for use FAULT LED Constant amber when a failure is detected in the ETERNUS DX system Blinks in amber when a component which requires preventive maintenance is detected MAINT LED Constant green when the system has its status set to Maintenance IDENTITY LED Constant blue when locate functionality is enabled by the GUI or CLI CACHE LED Constant green when data exists in cache memory Blinks in green when cached data is saved to the flash memory Remote LED Constant green when the system is turned on and off by additional external hardware Power switch Power indicator Fault Identify Maintenance Cache Ready Remote Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
16
Power On Procedure (3) Drive Enclosure LEDs
Identical for 2.5" and 3.5" DE IDENTIFY LED Constant blue when locate functionality is enabled by the GUI or CLI POWER LED The Drive Enclosure is operating normally and was switched on by the CM DE-ID (7-segment) Shows a 2-digit Drive Enclosure ID First digit is the SAS bus number DX500 S3: "0" and "1" DX600 S3: "0", "1", "2" and "3" Second digit is the DE number "01" = DE#1, "14" = DE#4… "3A" = DE#10 The ID is assigned automatically by the SAS backend cabling during the Add DE procedure DE ID Identify Fault Power Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014
17
Fujitsu Training Documentation
Power Off Procedure Hardware Installation ETERNUS DX500 S3 and DX600 S3 Verify with the customer that all server I/O is stopped Also confirm that the Cache LED in the Operator Panel is off Hold down the power switch of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will shutdown all Enclosures gracefully In case of moving ETERNUS to a new location, you naturally have to also disconnect the AC power cords from the PDUs after the system is powered off Make sure the Cache LED of the Controller Enclosure is off Power switch Cache Ready Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
18
CE Switch Panel - Function Buttons (1)
Fujitsu Training Documentation CE Switch Panel - Function Buttons (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Remove the CE front bezel to get access to the Function Buttons Located above the Power Switch Use the pin tool to operate one of the following functions See next slide for further details Enable / disable Maintenance Mode Change CM Master Reset the IP address of the FST port to factory default Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
19
CE Switch Panel - Function Buttons (2)
Fujitsu Training Documentation CE Switch Panel - Function Buttons (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 The operation can be performed by carrying out the following steps To toggle the system status between "Maintenance" and "Normal" Keep the Function Button pushed for three seconds The MNT LED lights green when the system is in Maintenance mode The MNT LED is off when the system is in Normal mode Switch the functionality of Master CM to the other Controller Module (1) Switch on "Maintenance Mode" (2) Push down the Function Button twice within three seconds The Master LED lights green to indicate the Master CM (3) Switch off "Maintenance Mode" Reset the FST port of the CM to the default values (2) Push down the Function Button three times within three seconds The MNT LED blinks green for a few seconds Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014
20
Fujitsu Training Documentation
Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014