Presentation is loading. Please wait.

Presentation is loading. Please wait.

Part 3 LABTQ /LABNET. Technical experience with testing ECO design parameters 20 years of Round Robin test on boilers and collaboration in LABNET/LABTQ.

Similar presentations


Presentation on theme: "Part 3 LABTQ /LABNET. Technical experience with testing ECO design parameters 20 years of Round Robin test on boilers and collaboration in LABNET/LABTQ."— Presentation transcript:

1 Part 3 LABTQ /LABNET. Technical experience with testing ECO design parameters
20 years of Round Robin test on boilers and collaboration in LABNET/LABTQ. Measurement state of the art (DGC)

2

3 Resulting in high quality of testing in the EU for appliances covered
Activities INTERCOMPARISONS (efficiency, emissions) on boilers & cookers. Good Laboratory Practise documents Investigations Resulting in high quality of testing in the EU for appliances covered

4 Activities  INTERCOMPARISONS (efficiency, emissions) on boilers & cookers. 1990 – 2012 several RRT tests on gas boilers & fuel oil boilers 2004 gas burner 2011 gas cooker Good Laboratory Practise documents Investigations

5 Inter-comparison WHAT IS IT? = Circulating the
same appliance through labs . . . . . . . .

6 Measurement and acquisition
module (reference) BOILER - Efficiency - T water in - T water out - Water flow - Gas flow - Gas pressure etc.. Measurement and acquisition (laboratory)

7 Water flow Danfoss Water temp. FR & Co. Pt 100 1/10-DIN Gas volume OVAL GAL 53 5m3/h + convert. Gas temp FP & Co. Pt 100 1/10-DIN Gas pressure JUMO 4 AP 30 Air temp FP & Co. Pt 100 1/10-DIN

8 ReproducibilityR = 4.5% rel.
INTERCOMPARISON 1991 Maximum Minimum

9 The reproducibility (R) is the value, below which the absolute difference between two single test results obtained with the same method on identical test material, under different conditions (different operators, different apparatus, different laboratories, and different time) may be expected to lie with a specified probability of 95% (ISO 5725).

10 WP1 GLP Efficiency (GLP document)
Good Laboratory Practice Document (G.L.P.) . J E B I A H F D G C Boiler Efficiency Intercomparison Improved Interlaboratory Reproducibility 1991 1996

11 Good Laboratory Practise documents
Activities INTERCOMPARISONS Good Laboratory Practise documents Two so far (Eff. & emissions) Investigations

12 Investigations Activities INTERCOMPARISONS
Good Laboratory Practise documents Investigations 7 projects with the EU support: BCR work on Efficiency of CH boilers Investigation on NOx and CO measurement of CH boilers Electrical testing of CH boilers (SAVELEC) Determination of Efficiency with losses (CH boilers) Direct or indirect 30% part load test: comparison Harmonized method for the calculation of uncertainty for efficiency Noise measurement of CH boilers Labs own investigations on various issues

13 BCR work on Efficiency of CH boilers
WP 1 Stability criteria DGC WP 2 Influence of ambient conditions GASTEC DTI WP 3 Uncertainty calculation CETIAT GASTEC WP 4 Heat contribution of the pump DGC GASTEC, CETIAT WP 5 Harmonisation of formulae GASTEC BRITISH GAS WP 6 Influence of the calorific value CETIAT DGC, GASTEC WP 7 Good laboratory practise DGC CETIAT, DTI, ARGB WP 8 Intercomparison DGC CETIAT, GASTEC, plus up to 9 additional participants. Investigation on NOx and CO measurement of CH boilers Electrical testing of CH boilers (SAVELEC) Determination of Efficiency with losses (CH boilers) Direct or indirect 30% part load test: comparison Harmonized method for the calculation of uncertainty for efficiency Noise measurement of CH boilers

14 Investigation on NOx and CO measurement of CH boilers
BCR work on Efficiency of CH boilers Investigation on NOx and CO measurement of CH boilers 1. Influence of Chemical Composition of the Gas 2. Influence of Chemical Composition of the Fuel Oil 3. Repeatability of Test and Influence of Atmospheric Pressure 4. Influence of Sampling System Characteristics 5. Influence of the NOx, CO, O2, CO2 Analyser. Characteristics on Measured NOx and CO Emission 6. Influence of Calibration Gases Report, Resumé 7. Development and Optimisation of Appropriate Procedures for the Periodical Control of the analysers 8. Integration of the Results of Work Packages 1 to 7 in an Updated CEN Technical Report 9. Intercomparison Electrical testing of CH boilers (SAVELEC) Determination of Efficiency with losses (CH boilers) Direct or indirect 30% part load test: comparison Harmonized method for the calculation of uncertainty for efficiency Noise measurement of CH boilers

15 Harmonized method for the calculation of uncertainty for efficiency
BCR work on Efficiency of CH boilers Investigation on NOx and CO measurement of CH boilers Electrical testing of CH boilers (SAVELEC) Determination of Efficiency with losses (CH boilers) Direct or indirect 30% part load test: comparison Harmonized method for the calculation of uncertainty for efficiency Noise measurement of CH boilers

16 WP5 Uncertainty calculation, ex for one meter = gas flow

17

18 Noise measurement of CH boilers
BCR work on Efficiency of CH boilers Investigation on NOx and CO measurement of CH boilers Electrical testing of CH boilers (SAVELEC) Determination of Efficiency with losses (CH boilers) Direct or indirect 30% part load test: comparison Harmonized method for the calculation of uncertainty for efficiency Noise measurement of CH boilers EUROPEAN METHOD FOR BOILER NOISE MEASUREMENT (BOILERNOISE project) Duration : 3 years Partners : CETIAT & GDF (Fr), BBRI (Be), BRE (UK), Istituto GIORDANO (It), OWI (Ge),VTT (Fi)

19 WHAT IS THE ACTUAL SITUATION FOR THE PARAMETERS NEEDED FOR ECODESIGN?
BOILER Full load efficiency Part load efficiency NOx Standby loss Electricity consumption HOT WATER APPLIANCES Hot water efficiency Other parameter= same as above

20 ReproducibilityR = 4.5% rel.
INTERCOMPARISON 1991 Maximum Minimum PART LOAD EFFICIENCY R= about 3 (+/- 1,5%) to 4,5 (+/- 2,25%) FULL LOAD EFFICIENCY R = about 3 (+/- 1,5%) STANBY LOSSES (+/- 50%?)

21 WP2 GLP NOx CO (GLP document)
+/ - 20% 70 mg/kWh gross = ca 78 mg/kWh net SMT 4 - CT Improvement of Interlaboratory Reproducibility for NOx and CO Measurements

22 WHAT IS THE ACTUAL SITUATION FOR THE PARAMETERS NEEDED FOR ECODESIGN
WHAT IS THE ACTUAL SITUATION FOR THE PARAMETERS NEEDED FOR ECODESIGN? (tested during RRTs) BOILER Full load efficiency +/- 1,5 % Rel Part load efficiency +/- 2 % Rel NOx +/- 20 % Rel (at the limit proposed) Standby loss +/- 50 % Rel (?) Electricity consumption (?) Noise (?) HOT WATER APPLIANCES Hot water efficiency (?) Other parameter= same as above