Presentation is loading. Please wait.

Presentation is loading. Please wait.

A Design Approach to Mitigate Corrosion Under Insulation

Similar presentations


Presentation on theme: "A Design Approach to Mitigate Corrosion Under Insulation"— Presentation transcript:

1 A Design Approach to Mitigate Corrosion Under Insulation
Goldeneye Project, St Fergus, Scotland Gwyn Evans FWEL 14/01/04

2 Specification Development
Conceptual Design Insulation and Coating Extent Insulation systems Coating systems “ Cradle to Grave “

3 Insulation Systems

4 Insulation Systems Materials Small Bore Piping Sealing Training
Polymeric Sheeting Ulvashield UV Cured FRP Fibaroll VECR Small Bore Piping Sealing Training

5 Insulation Systems Test rig

6 Coating Systems for Insulated Surfaces

7 Coating Systems for Insulated Surfaces

8 Thermally Sprayed Aluminium
TSA System Surface Preparation Sa 3 Aluminium, grade Al 99.5 to BS EN 2263 at 200microns thick. (+/- 20%) by Arc sprayed wire method Seal Coat 120°C & Less Epoxy Based Sealer 121 °C & Above Silicone Aluminium Sealer

9 Thermally Sprayed Aluminium
Applicator Qualification AWS C2.16 Restricted access Adhesion 7 Mpa for both carbon and stainless steel surfaces