S65-V Color Sensors
2
CIE Chromaticity Diagram
B R All colors can be created using Red, Green and Blue (RGB) combinations White is composed of RGB components in equal percentage White is not a color and decreases its intensity as it becomes gray and then black
3
Munsell Color Diagrams
4
Color Sensor Types 3 RGB light sources 1 normal Receiver
1 white light source 3 RGB receivers Older technology Datasensor TEC Baumer FKDM22 IDEC SA1J Keyence CZ-K Omron E3MC Sick CS1/CS3/CSM1 Wenglor FT05 State-of-the-art technology Better spot concentration More chromatic sensitivity Improved precision and stability Datasensor S65-V IDEC SA1K SensoPart FT50C Wenglor FP04/FP11
5
C or C+I ? YES NO C = Chromaticity C+I = Chromaticity + Intensity
Intensity: insensitive - High depth of field - Detection of different colors on reflective surfaces - Gray-scale not detected Intensity sensitive - B/W and gray-scale recognition Distinguishes a pure color from the same one with white dots or lines Distinguishes different surfaces with the same color YES NO
6
New Models Available
7
S65-V: Highlights
8
S65-V Application Examples
9
S65-V Application Functions
Quality control Object positioning Object sorting Presence control Color coding OK
10
Lid presence detection on rotating cans
Application Notes Lid presence detection on rotating cans INDUSTRIAL SECTOR Bottling, beverage and liquid MACHINERY/PLANT TYPE Can filling machine MACHINERY/PLANT SECTION Seal application APPLICATION DESCRIPTION The control of an aluminium seal presence on rotating cans before packaging was necessary, regardless of the different colors amongst which an aluminium-colored model predominated. The can border is detected in order to activate the output only with seal absence or damage.
11
Detection of semi-transparent objects
Application Notes Detection of semi-transparent objects INDUSTRIAL SECTOR Wire production MACHINERY/PLANT TYPE Plastic wire-drawing machine MACHINERY/PLANT SECTION End of line APPLICATION DESCRIPTION The sensor controls the quality of the wire to exclude parts with too much or insufficient transparent sections. Green wire with transparent contour
12
Color detection of distant objects with reflector
Application Notes Color detection of distant objects with reflector R8 reflector INDUSTRIAL SECTOR Automotive industry MACHINERY/PLANT TYPE Automotive electrical part assembling MACHINERY/PLANT SECTION Fuse production control APPLICATION DESCRIPTION Each fuse has a different color according to its amperage value. The sensor, thanks to the use of an R8 reflector, functions in a through beam mode, obtaining longer operating distances, reliable detection and a good depth of field in the 'C' mode configuration.
13
Opaque mark detection on shiny surfaces
Application Notes Opaque mark detection on shiny surfaces INDUSTRIAL SECTOR Bottling and beverage MACHINERY/PLANT TYPE Bottling machines MACHINERY/PLANT SECTION Capping enclosure section APPLICATION DESCRIPTION The sensor detects the mark on the champagne bottles in order to stop the bottle in the correct position for successive operations.
14
Shiny mark detection on opaque surfaces
Application Notes Shiny mark detection on opaque surfaces INDUSTRIAL SECTOR Bottling and beverage MACHINERY/PLANT TYPE Bottling machines MACHINERY/PLANT SECTION Capping enclosure section APPLICATION DESCRIPTION The sensor detects the mark on the wine bottles in order to stop the bottle in the correct position for successive operations.
15
Color discrimination with slight color variations
Application Notes Color discrimination with slight color variations INDUSTRIAL SECTOR Automotive industry MACHINERY/PLANT TYPE Automatic assembling lines MACHINERY/PLANT SECTION Plastic accessory sorting APPLICATION DESCRIPTION The sensor detects small tone differences of same-colored parts in order to sort each product in the correct assembling line. Color C Color B Color A
16
Detection of the correct wiring
Application Notes Detection of the correct wiring INDUSTRIAL SECTOR Automotive industry MACHINERY/PLANT TYPE Automotive electrical part assembling MACHINERY/PLANT SECTION Electrical circuit wiring APPLICATION DESCRIPTION The sensor detects the color pattern in order to verify the correct wire sequence. The wire color sequence is transmitted to a PC through the serial interface.
17
Application Notes Check the color inside a bottle and apply the proper color marking to the cap INDUSTRIAL SECTOR Bottling, beverages and liquid MACHINERY/PLANT TYPE Liquid color bottling MACHINERY/PLANT SECTION Capping and color marking APPLICATION DESCRIPTION The sensor detects the color of the liquid inside each bottle and provides information for marking the color on the cap.
18
S65-V Control Panel
19
S65-V Sensor Configuration
Place the object to be detected Press SET for 2 seconds Click SEL until correct output is displayed Click SET to save setting OUTPUT SELECTION SENSING MODE Click SEL to select C or C+I Click SEL repeatedly to select from 10 levels TOLERANCE LEVEL
20
S65-V Sensor Programming (1)
Action: Place the sensor in front of the color to be detected, typically 20mm; sensor will sample the color to be detected 1) Preliminary operation • Press and hold Set > 2 seconds • Channel 1 (‘SEt1’) is selected by default • Click Select until desired channel is displayed • Click Set to save selection 2) Channel Selection • Click Select to choose: Color or Color + Intensity (Color is the default mode) 3) C or C+I color detection type Device status: Output LED: OFF Output Status LEDs: All OFF Display: C (Color) or C_I (Color + intensity)
21
S65-V Sensor Programming (2)
4) Tolerance level Action: • Click Select repeatedly until desired tolerance level is displayed;10 levels available • Click Set to save tolerance setting 3) C or C+I color detection type Action: • Click Set to save the selection Device status: Output LED: ON Output Status LEDs: Selected channel ON Display: toL0 (most selective) toL1 (tolerance level 1)..... …….toL9 (less selective) Output LED: ON (if saved) Output Status LEDs: Selected channel ON Display: “updt” (flashing 2 seconds)
22
S65-V Delay Function 1) Delay setting 2) Turn to operating mode
Action: Press Set for 6 seconds • Click Select repeatedly until desired delay setting is displayed (d_00 to d_40) Device status: Output LED: OFF (no target) Channel Status LEDs: All OFF Display: d_00 (no delay) d_05 (5 ms delay) d_10 (10 ms delay) d_20 (20 ms delay) d_30 (30 ms delay) d_40 (40 ms delay) 2) Turn to operating mode Action: Click Set to store settings Device status: Output LED: OFF (no target) Channel Status LEDs: All OFF Display: run (no delay selected) or rund (run delay selected)
23
S65-V Visualization Setting
SEL Press button for 2 seconds to initiate sequential display Sensor configuration can be viewed during run mode To view sensor settings, press Select for 2 seconds or more. The output channel, sensing mode, and tolerance level will then be displayed sequentially, followed by the delay interval (applicable to all channels). At the end of the sequence, the display will indicate ‘run’ or ‘rund’ (depending on the delay setting). Repeat for each channel
24
MOUNTING ON GLOSSY SURFACES
S65-V InstallationNote MOUNTING ON GLOSSY SURFACES
25
S65-V vs. Baumer FKDM22 FKDM22N1901/S14F Light Source 3 RGB LEDs
Spot size 3 x 5mm Sensing distance 40mm Tolerance 5 levels Algorithm C+I Response time 340 µs (1.5 kHz) Channel/output 4 - PNP Setting 3 push-buttons Indicators 8 LEDs Housing Zinc die-cast IP67 Dimensions 23 x 50 x 50mm Connector M12 8-poles rot. Other features synch. input RS232 interface
26
S65-V vs. Wenglor FP04/FP11 Light Source 1 white LED
Spot size Ø 2 / 10mm Sensing distance 30-50/10-100mm Tolerance 7 levels Algorithm C+I Response time 300µs (1.66 kHz) Channel/output 3 - PNP Setting push-button + switch Indicators 5 LEDs Housing Plastic IP67 Dimensions 20 x 50 x 50mm Connector M12 8-poles rot. Other features teach-input RS232 interface delay
27
S65-V vs. Sensopart FT50C Light Source 1 white LED Spot size Ø 4mm
Sensing distance 10-30mm Tolerance 5 levels Algorithm C+I Response time 1ms (500Hz) Channel/output 3 - PNP Setting 2 push-buttons Indicators 7 LEDs Housing ABS plastic IP67 Dimensions 17 x 50 x 50mm Connector M12 8-poles rot. Other features teach input synch input delay
28
S65-V vs. Sick CS1/CS3 Light Source 3 RGB LEDs
Spot size 2 x 4mm/Ø13 mm Sensing distance 12.5/60mm Tolerance 5 levels Algorithm C+I Response time 0.5/2.5ms (1/0.3kHz) Channel/output 1 or 3 - NPN or PNP Setting push-button + switch Indicators 2 LEDs Housing Zinc die-cast IP67 Dimensions 30 x 53 x 80mm Connector M12 8-poles Other features teach input blanking input delay
29
S65-V vs. Omron E3MC Light Source 3 RGB LEDs Spot size Ø 12mm
Sensing distance 60mm Tolerance 7 levels Algorithm C or C+I Response time 1/6ms (500/80 Hz) Channel/output 1 or 4 - NPN or PNP Setting push-button + switch Indicators 5 LEDs + bar-graph Housing Zinc die-cast IP66 Dimensions 30 x 53 x 80mm Connector M12 8-poles Other features teach in input synch input delay
30
S65-V vs. IDEC SA1J Light Source 3 RGB LEDs Spot size Ø 2.5 - 8mm
Sensing distance mm Tolerance 5 levels Algorithm C or C+I Response time 0.3/5ms (1.5/0.1 kHz) Channel/output 1 or 3 - PNP or NPN Setting push-button + switch Indicators 1 / 3 LEDs Housing Aluminum IP67 Dimensions 30 x 50 x 80mm Connector cable 5 or 7 poles Other features teach input synch input delay
31
S65-V vs. Sick CSM1-P1114/N1114 Light Source 3 RGB LEDs
Spot size 1.5 x 6.5mm Sensing distance 12.5mm Tolerance 3 levels Algorithm C+I Response time 500µs (1kHz) Channel/output 1 - NPN or PNP Setting 1 push-button Indicators 1 LED Housing ABS plastic IP67 Dimensions 12 x 40 x 22mm Connector M12 4-poles Other features teach input delay
32
Performance you can count on!
S65-VIP Low Cost!! Easy setting Wide white LED spectrum Good sensing distance 10 tolerance levels C or C+I selection Short response time High switching frequency 3 independent channels 3 NPN or PNP outputs 4-digit display & LEDs indicator Compact housing IP67 Standard 25x50x50 mm M12 standard conn. External synchronization RS485 serial interface version Programmable delay function Small spot Performance you can count on!
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.