Download presentation
Presentation is loading. Please wait.
Published byDomenic Wade Modified over 6 years ago
1
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Schematic illustration of the geometry
2
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Numerical finite difference method grid
3
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Effect of Ha and Ri on streamlines (upper row) and isotherms (lower row) for aiding lid-driven case and Φ = 73 deg, solid lines φ = 0, and dashed lines φ = 0.03: (a) Ri = 0.1, (b) Ri = 1, and (c) Ri = 10
4
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Effect of Ha and side wall inclination on streamlines (upper row) and isotherms (lower row) for aiding lid-driven, Ri = 1.0, solid lines φ = 0, and dashed lines φ = 0.03: (a) Φ = 66 deg and (b) Φ = 80 deg
5
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Effect of Ha and Ri on streamlines (upper row) and isotherms (lower row) for opposing lid-driven and Φ = 73 deg, solid lines φ = 0, and dashed lines φ = 0.03: (a) Ri = 0.1, (b) Ri = 1, and (c) Ri = 10
6
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Effect of Ha and side wall inclination on streamlines (upper row) and isotherms (lower row) for opposing lid-driven case, Ri = 1.0, solid lines φ = 0 and dashed lines φ = 0.03: (a) Φ = 66 deg and (b) Φ = 80 deg
7
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Distributions of local Nusselt number along the inclined right side wall NuR for Φ = 73 deg, φ = 0.03, and Ri = 1.0
8
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Distributions of local Nusselt number along the inclined right side wall NuR for Φ = 73 deg, φ = 0.03, and Ha = 0
9
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Distributions of local Nusselt number along the inclined right side wall NuR for Φ = 73 deg, Ha = 50, and Ri = 1.0
10
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Variation of average Nusselt number along the inclined right side wall Nuav for Φ = 73 deg, Ri = 1.0
11
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Variation of average Nusselt number along the inclined right side wall Nuav for Φ = 73 deg, Ha = 10
12
Date of download: 10/21/2017 Copyright © ASME. All rights reserved. From: Magnetic Field Effect on Mixed Convection in Lid-Driven Trapezoidal Cavities Filled With a Cu–Water Nanofluid With an Aiding or Opposing Side Wall J. Thermal Sci. Eng. Appl. 2016;8(3): doi: / Figure Legend: Variation of average Nusselt number along the inclined right side wall Nuav for Ha = 10, Ri = 1.0