Presentation is loading. Please wait.

Presentation is loading. Please wait.

Luminosity Measurement using BHABHA events

Similar presentations


Presentation on theme: "Luminosity Measurement using BHABHA events"— Presentation transcript:

1 Luminosity Measurement using BHABHA events
Tel Aviv University HEP experimental Group MDI SLAC Ronen Ingbir Lumical - A Future Linear Collider detector HEP Tel Aviv University

2 Strip design ΔE~0.31√E L R Cracow
Lumical - A Future Linear Collider detector

3 Pad design 15 cylinders * 24 sectors * 30 rings = cells 8 cm 0.31 cm Silicon 28 cm 0.34 cm Tungsten Cell Size 1.3cm*2cm> 1.3cm*6cm< ~1 Radiation length ~1 Radius Moliere L R 6.10 m Lumical - A Future Linear Collider detector HEP Tel Aviv University

4 Reconstruction Algorithm
We explored two reconstruction algorithms: Events Num. T.C Awes et al. Nucl. Inst. Meth. A311 (1992) 130. The log. weight fun. was designed to reduce steps in a granulated detector : 1. Selection of significant cells. 2. Log. smoothing. Log. weight. E weight. Lumical - A Future Linear Collider detector HEP Tel Aviv University

5 Logarithmic Constant 400 GeV Constant value Constant value
After selecting: We explored a more systematic approach. The first step is finding the best constant to use under two criteria: 1. Best resolution. 2. Minimum bias. Constant value Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University

6 Energy dependent constant
The goal is to find a global weight function. Is the the log. weight constant really a constant ? Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University

7 Shower reconstruction
What happens when we select the best log. weight constant ? Num. of Cells Num. of Sectors Shower size Log. Weight Selection Energy portion (%) Num. of Cylinders Most of the information is in the selected cells. En>90% Lumical - A Future Linear Collider detector HEP Tel Aviv University

8 Magnetic field Lumical - A Future Linear Collider detector
HEP Tel Aviv University

9 Background studies BHWIDE + CIRCE
Lumical - A Future Linear Collider detector HEP Tel Aviv University

10 Geometric acceptance In Eout-Ein P= Eout+Ein Out Energy Resolution
3 cylinders 33 mrad 2 cylinders 1 cylinders Lumical - A Future Linear Collider detector HEP Tel Aviv University

11 Left-Right balance L R Simulation distribution
Distribution after acceptance and energy balance selection Right signal - Left signal Left side detector signal Right side detector signal Lumical - A Future Linear Collider detector HEP Tel Aviv University

12 Energy resolution Ntuple 31% 29% 42% 24% 45% 46% 25% 49% No cuts
Ntuple No cuts With cuts Pure electrons 31% 29% Bhabha 42% 24% Bhabha + Beamstrahlung 45% Bhabha + Beamstrahlung + Beam spread (0.05%) 46% 25% Bhabha + Beamstrahlung + Beam spread (0.5%) 49% Lumical - A Future Linear Collider detector HEP Tel Aviv University

13 Angular resolution Lumical - A Future Linear Collider detector
HEP Tel Aviv University

14 ‘Pure’ electrons simulation
Bias study ‘Pure’ electrons simulation Bhabha+Beam+BS(5e-4) Lumical - A Future Linear Collider detector HEP Tel Aviv University

15 Real life algorithm Working with both sides of the detector and looking at the difference between the reconstructed properties: (In real life we don’t have generated properties) Lumical - A Future Linear Collider detector HEP Tel Aviv University

16 Dense design 0.1 cm Silicon 0.55 cm Tungsten 0.34 cm Tungsten
Lumical - A Future Linear Collider detector HEP Tel Aviv University

17 Moliere radius & Radiation length
Detector Signal 0.8cm 1.1cm Z (cm) 30 radiation length detector 47 radiation length detector Lumical - A Future Linear Collider detector HEP Tel Aviv University

18 New geometric acceptance
Events Energy Resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University

19 Optimization Lumical - A Future Linear Collider detector
HEP Tel Aviv University

20 Margins in between cells
Energy resolution Polar resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University

21 Maximum peak shower design
Our basic detector is designed with 30 rings * 24 sectors * 15 cylinders = 10,800 channels Do we use these channels in the most effective way ? 20 cylinders 10 cylinders 24 sectors * 15 rings * (10 cylinders + 20 cylinders) = 10,800 channels 4 rings 15 rings 11 rings 30 rings cylinders Lumical - A Future Linear Collider detector HEP Tel Aviv University

22 Polar reconstruction Maximum peak shower design Basic Design
0.11e-3 rad 0.13e-3 rad Constant value Angular resolution improvement without changing the number of channels Other properties remain the same Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University

23 High Statistics MC BHWIDE + fast detector simulation
Lumical - A Future Linear Collider detector HEP Tel Aviv University

24 R&D status & future steps
Pure electron MC Detector properties Events selection ‘Real physics’ MC Bhabha + Beamstrahlung + Beamspread High statistics MC Luminosity with a crossing angle Luminosity with polarised beams (Gideon Alexander) ‘Real physics’ MC + digitization + elec. noise + New max peak design + Margins Final optimization Lumical - A Future Linear Collider detector HEP Tel Aviv University

25 THE END Lumical - A Future Linear Collider detector
HEP Tel Aviv University


Download ppt "Luminosity Measurement using BHABHA events"

Similar presentations


Ads by Google