1 Volume 16, Issue 1, Pages 215-222 (January 2017)
A novel conformal superficial high-dose-rate brachytherapy device for the treatment of nonmelanoma skin cancer and keloids  Clara Ferreira, Daniel Johnson, Karl Rasmussen, Clinton Leinweber, Salahuddin Ahmad, Jae Won Jung  Brachytherapy  Volume 16, Issue 1, Pages (January 2017) DOI: /j.brachy Copyright © 2016 American Brachytherapy Society Terms and Conditions

2 Fig. 1 Conformal superficial brachytherapy (CSBT) device showing possible seed expansions for positioning in the skin surface to conform to treatment lesion. Time and position of each seed can be controlled to optimize the treatment. Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

3 Fig. 2 (a) Clockwise direction, starting from top left: frontal view of the template with no rods extended, field 1 (yellow), superposition of fields 1 and 2 (orange), superposition of fields 1, 2, and 3 (red). (b) Representation of total dose distribution from all fields added. “(For interpretation of the references to color in this figure legend, the reader is referred to the Web version of this article.)” Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

4 Fig. 3 Device holder and CSBT device positioned at the target.
Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

5 Fig. 4 Scanned device template exported to BPS and used for planning different seed positions. Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

6 Fig. 5 Profile doses at the surface for planned and measured 125I seed matrix. Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

7 Fig. 6 (a) Plot of normalized PDD and profiles for 90Sr–90Y and 6 MeV electron EBRT and isodose lines from film scans for PDD and (b) profiles for external 6 MeV electron beams and 90Sr–90Y single seed and multiple adjacent 90Sr–90Y placements. Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions

8 Fig. 7 MCNPX 2.6% depth dose and radial simulations for the dose per decay profile of model used for experimental setup using the 142Pr glass rod. The dose falloff is steep and drops to minimal values at points beyond 5 mm. Brachytherapy  , DOI: ( /j.brachy ) Copyright © 2016 American Brachytherapy Society Terms and Conditions