Operational Experience with Zinc Injection at Angra 2
B. Stellwag 1), M. Ruebenich 2), M. de Oliveira 2) M. Menezes 2), V. Schneider 1), U. Staudt 3) Bitte beachten Sie auch die Beispieldatei AREVA_Beispiele auf dem Softwareserver sw_pool.xp. Dort erhalten Sie Hinweise auf die Verwendung von Fotos, Farben und Gestatungselementen. 1) Framatome ANP GmbH, Germany 2) Eletronuclear, Brazil 3) VGB PowerTech, Germany 2006 ISOE International Symposium, Essen, Germany
3
Contents Zn Injection at Angra 2: Background and Objective
Preparatory Work Results: - Primary Coolant Chemistry Data - RCS Surface Activity Data - Dose Rate Trends Summary and Conclusions
4
Average Annual Collective Doses at PWR Plants Around the World
5
Background and Objective
Stellites in RPV of pre-Konvoi and Konvoi plant generations were substituted by Co-free wear resistant materials Measure resulted in very low radiation fields at RCS. Stellites in RPV of Angra 2 similar to four-loop 1300 MW class Siemens PWRs which went commercial in 80´ies Zinc injection was implemented at Angra 2 for mitigation of future buildup of high dose rates at the RCS Zinc injection started two days after first criticality of Angra 2
6
Angra 1 and 2 / Brazil April 2002
Angra 2: 1356 MWe four-loop PWR built by Siemens, 1st Criticality 07/2000
7
Preparations for Zinc Injection at Angra 2
Dosing concept: Injection of zinc acetate by chemical injection system Use of zinc, depleted in Zn-64 (< 5% Zn-64) Zinc analysis by graphite-tube atomic absorption spectrometry Analysis frequency for Zn and Fe initially once per day, for Cr and Ni once per week, monitoring of coolant activity Target concentration 5 ppb Zn in primary coolant Zinc injection started during commissioning of Angra 2 in Phase D, power tests
8
Results: Primary Coolant Chemistry Data
9
Zn Concentration of Primary Coolant at Angra 2
10
Fe Concentration of Primary Coolant at Angra 2
11
Co-58 & Co-60 Activity Data of Primary Coolant at Angra 2
12
Summary: Coolant Chemistry Properties
Zinc could be detected already at the start of zinc injection Target of 5 ppb Zn reached 4 weeks later Avg. coolant Fe concentration of 1.2 ppb Fe is at the lower end of the range typical of Siemens plants Co-60 content of primary coolant at Angra 2 is lower than that of sister plants despite of lower Co-60 pickup of RCS surfaces Angra 2 primary coolant chemistry Fe and Co-60 levels can be taken as an indicator for low corrosion product release and hence high-quality oxide layers on RCS materials
13
Results: RCS Surface Activity Values and Dose Rates
14
Co-60 Hot Leg Surface Activity Data of Siemens PWRs
15
Co-60 Cold Leg Surface Activity Data of Siemens PWRs
16
Hot Leg Average Contact Dose Rates at Siemens Plants
17
Cross-Over Piping Avg. Contact Dose Rates at Siemens Plants
18
Dose Rate in SG Channel Head of Siemens PWR Hot Leg
19
Summary: RCS Dose Rates and Surface Activities
Zn injection at Angra 2 resulted in a Co-60 surface activity level in the range of pre-Konvoi and Konvoi plants RCS contact dose rates and SG channel head data at Angra 2 are also in the range of pre-Konvoi and Konvoi plants Angra 2 dose rates are at least three times lower than that of sister plants with similar stellite inventory
20
Conclusions, Recommendations
Angra 2 is the first and only PWR plant injecting zinc from start of first criticality Low Fe and Co-60 levels of primary coolant, hence - low corrosion product release - high quality oxide layers on RCS materials Results of zinc injection met all of the expectations of the operator of Angra 2 Full-system decontamination and subsequent zinc injection is an attractive option for reducing RCS dose rates of mature PWR plants - quickly - efficiently - permanently.