IS FOR HAZARDS AT HOSPITALS
SKC is pleased to provide elp in sampling for target compounds. H
2
COMMON CHEMICAL HAZARDS IN HOSPITALS
ANESTHETIC GASES Halothane, Isoflurane Desflurane, Enflurane Sevoflurane STERILANT GASES Ethylene Oxide STERILANT LIQUIDS Glutaraldehyde Hydrogen Peroxide Peracetic acid SOLVENTS Formaldehyde
3
ANESTHETIC GASES DEFINING THE HAZARD
U.S. NIOSH has published a document that describes the occupational hazards of waste anesthetic gases in hospitals. See
4
NIOSH DEFINES THE WORKERS POTENTIALLY EXPOSED
Workers in operating facilities with no automatic ventilation or scavenging systems or operating facilities where these systems are in poor condition Workers in recovery rooms where gases exhaled by recovering patients are not properly vented or scavenged
5
ANESTHETIC GASES ACTIVE SAMPLING METHODS
Enflurane, halothane, and isoflurane can be sampled using sorbent tubes containing Anasorb® 747 sorbent to assess short-term (15-minute) or long-term (2-hour) exposures by OSHA Method 103. SKC A
6
ANESTHETIC GASES PASSIVE SAMPLING METHOD
SKC research chemists have validated the use of SKC diffusive sampler containing 500 mg of Anasorb 747 to sample the halogenated anesthetic gases. SKC
7
ANESTHETIC GASES SKC PASSIVE SAMPLER VALIDATION
The SKC was fully validated for isoflurane and halothane and partially validated for desflurane, enflurane, and sevoflurane. See the complete validation report at
8
STERILANT GASES DEFINING THE HAZARD
Ethylene oxide (EtO) gas sterilizers have been used by hospitals for many years to sterilize surgical equipment and supplies that cannot tolerate excessive heat, moisture, or abrasive chemicals. NIOSH has a criteria document on this topic at
9
ETHYLENE OXIDE ACTIVE SAMPLING METHOD
Ethylene oxide can be sampled using sorbent tubes containing chemically coated Anasorb 747 sorbent to assess short-term (15-minute) or long-term (4-hour) exposures by OSHA Method 1010. SKC
10
ETHYLENE OXIDE PASSIVE SAMPLING METHOD
Passive samplers containing the same sorbent specified in OSHA 1010 can be used to assess TWA or short-term exposures. The validation done by SKC chemists can be reviewed at SKC
11
STERILANT LIQUIDS DEFINING THE HAZARD
New chemical agents are now being used to sterilize surgical tools, diagnostic instruments, and surfaces. NIOSH recently published a report on a hospital cleaner containing multiple chemical agents that has caused health effects on exposed workers. See LSO
12
GLUTARALDEHYDE ACTIVE SAMPLING METHOD
Cassettes containing 2 glass fiber filters treated with 2,4-DNPH and phosphoric acid can be used at flow rates up to 2 L/min to assess short-term (5 to15 minute) or long-term (4-hour) exposures by OSHA Method 64. SKC
13
GLUTARALDEHYDE PASSIVE SAMPLING METHOD
The SKC UMEX 100 passive sampler that contains a chemically coated tape can be used to sample glutaraldehyde using a calculated sampling rate of 14 ml/min. SKC
14
HYDROGEN PEROXIDE ACTIVE SAMPLING METHOD
U.S. OSHA released Method 1019 in 2016 for the collection of hydrogen peroxide using chemically coated filters SKC This was a welcome replacement to previous methods using impingers.
15
PERACETIC ACID ACTIVE SAMPLING METHOD
There is no U.S. agency sampling method available at this time for peracetic acid. SKC supplies a chemically coated silica gel tube to meet the requirements of a French agency method. SKC UC or UC. The flow rate of 1 L/min is critical in achieving reliable results. Given the high pressure drop of the sample media, heavy duty pumps such as the SKC AirChek Touch or XR5000 should be used.
16
SOLVENTS DEFINING THE HAZARD
There can be a large number of various solvents in hospital laboratories and research facilities. Formaldehyde is used principally as a water-based solution called formalin and is a bactericide, tuberculocide, fungicide, virucide, and sporicide.
17
FORMALDEHYDE ACTIVE SAMPLING METHODS
There are a number of agency methods using sorbent tubes for formaldehyde: OSHA 52 using coated XAD-2 tubes SKC (TWAs) or (STELs) NIOSH 2541 using coated XAD-2 tubes SKC NIOSH 2016 using coated silica gel tubes SKC
18
FORMALDEHYDE PASSIVE SAMPLING METHOD
The SKC UMEX 100 passive sampler has been validated by OSHA Method 1007 for 15-minute STELs or 8-hour TWA compliance sampling. Note: OSHA requires that active sampling be done when the source of formaldehyde is formalin due to chemistry reasons. SKC
19
BIOLOGICAL HAZARDS IN HOSPITALS
INCLUDE KNOWN STRAINS OF Bacteria Viruses Fungi Other microorganisms ALSO INCLUDE NEW PATHOGENS FOR SARs MRSA Bird Flu
20
AIR SAMPLING FOR VIABLE BACTERIA AND FUNGI
The SKC BioStage is a single-stage cascade impactor used to collect viable samples following NIOSH Methods 0800 and 0801. Growth medium (agar) in standard culture plates is supplied by an environmental microbiology lab for use with this sampler. SKC
21
PUMP PARTNER FOR THE SKC BIOSTAGE
The SKC Biostage can be attached directly to the SKC QuickTake 30 pump using the mounting bracket. Flow rates of 28.3 L/min for sample times of 5 minutes or less are typically used. SKC K
22
SPECIAL NOTE ON SAMPLING FOR VIRUSES
ACGIH reports that air sampling for viruses is not routinely done for indoor air studies. Viruses do not remain long in the environment and do not multiply alone on organic substrates. Research and public health agencies may do air sampling to research transmission of airborne viral diseases. This technique was used by NIOSH during the SARs response.
23
AIR SAMPLING OPTIONS VIRUSES
The evaluation method chosen to collect viral samples depends on the virus itself, the environmental conditions, and the analysis techniques available.
24
SAMPLING FOR MRSA Methicillin-resistant Staphylococcus Aureus (MRSA) is normally found as a surface contaminant. Sterile swabs are typically used for sampling followed by growth culture. SKC
25
THANK YOU FOR YOUR ATTENTION!