I.- Relative Spectral Response: Corrected of green light contamination II.-Flat Fields with Internal Calibration Lamps during Commissioning Luisa M. Lara IAA-CSIC Granada (SPAIN)
2
Green light contamination in the UV range.
WAC Relative Spectral Response – Data from Sept. ’01, warm CCD at T=292 K NAC Relative Spectral Response – Data from Aug. ’01 and July ’03 with cold CCD (~ K). Relative (and/or absolute) detector measurements not available for the NAC Delta Calibration. Green light contamination in the UV range.
3
Other OSIRIS UV filters (specially the NAC ones) are not in Lindau a similar correction cannot be done for the Relative Spectral Response of the CCD#243 NAC FM.
5
II.-Flat Fields with Internal Calibration Lamps during Commissioning Luisa M. Lara IAA-CSIC Granada (SPAIN)
6
WAC and NAC “flats” (should be called “lamp images”) with Main Internal Calibration Lamp – Data from Slot 2b Commissioning (June ’04)
7
Available Data for Main Lamps
WAC Available Data for Main Lamps Empty Red640 Green535 Vis610 Na589 NH2 571 OI 630
8
Lab Calibration Lab Calibration Commissioning Commissioning Green
Empty Empty OI 630 Commissioning Commissioning Green Empty Empty OI 630
9
NAC Available Data Main ffp-vis, orange645 ffp-vis, green535
ffp-vis, blue480 ffp-vis, red740 ffp-vis, ffp-ir Ortho800, ffp-ir Near-ir, ffp-ir ffp-vis, hydra700 Fe2O3, ffp-ir
10
Processed images of the main internal calibration lamps acquired with filter combinations (ffp-vis,blue480), (ffp-vis,red740) and (ffp-vis,ffp-ir) Lab Calibration Commissioning
11
FFP-Vis, Orange 645
12
Lab Calibration Commissioning
Average in columns (solid line) and in rows (dotted line) of a normalized* image of the main and internal calibration lamps acquired with filter combination (ffp-vis,red740). Lab Calibration Commissioning Normalization with the mean value in a squared area of 200x200 pixels around the central pixel of the CCD. Normalization with the median
13
Conclusions There WAS a noticeable difference between the CCD spectral response measured in the lab and in the OSIRIS Calibration setup at wavelengths shorter than ~350 nm, either for the WAC FM and the NAC Pre-FM. Problem of green light contamination in the UV range of the monochromator is being assessed. Main Internal Calibration Lamps performance during commissioning remains as during the ground calibration.