Presentation is loading. Please wait.

Presentation is loading. Please wait.

EUDET JRA3, Activity Obninsk State University

Similar presentations


Presentation on theme: "EUDET JRA3, Activity Obninsk State University"— Presentation transcript:

1 EUDET JRA3, Activity Obninsk State University
DESY. EUDET meeting 8-9 Dec 2005, DESY Valeri Saveliev Obninsk State University, Russia / DESY, Hamburg

2 Main Activity in Frame JRA3
Physics and Detector Simulation, R&D project on the New Photodetectors for ILC Hadron Calorimeter System New concept of Hadron Calorimeter System on Base Fe/Si structure, 8 Dec 2005 Valeri Saveliev

3 Physics and Detector Simulation
Study of the SM Higgs Sensitivity, Study the Response of ILC Spectrometer with full Monte Carlo Simulation Frames: Geant3, Geant4, Prototype Study and Analysis of experimental data from Test Beams 8 Dec 2005 Valeri Saveliev

4 Physics and Detector Simulation
We got the funding for the development the regional branch of Net for the Grid Mathematical Modeling, Start the modernization of the Computer Cluster 8 Dec 2005 Valeri Saveliev

5 R&D New Photodetectors for ILC Hadron Calorimeter
Concept of Hadron Sc Tile Calorimeter – with direct light readout from Scintillator Tile by SiPM Sc. Cells SiPM module WLS 8 Dec 2005 Valeri Saveliev

6 R&D New Photodetectors for ILC Hadron Calorimeter
New Concept of Hadron Sc Tile Calorimeter – direct light readout from Scintillator Tile by Advance Silicon Photomultiplier Sc. Cell Sc. Cell SiPM 8 Dec 2005 Valeri Saveliev

7 R&D Project on the New Photodetector
Study of the Light Balance and Propagation in the Sc Tiles for the ILC Hadron Calorimeter , Development of the Advance Silicon Photomultipliers, Test setup for the Testing of the Scintillator Tile – Advance Silicon Photomultiplier, Prototyping and Test of the Stintillator - Silicon Photomultiplier Hadron Calorimeter Modules, 8 Dec 2005 Valeri Saveliev

8 R&D Project on the New Photodetector
Collaboration with: SensL, Cork, Ireland Company with connection to the TYNDAL National Institute of Ireland ( Advance Si technology ) 8 Dec 2005 Valeri Saveliev

9 Concept of Hadron Sc Tail Calorimeter with Direct Readout
Tasks: Blue range sensitivity of the Advance Silicon Photomultiplier, Large area of the Advance Silicon Photomultiplier. 8 Dec 2005 Valeri Saveliev

10 SiPM Technology General view 1x1 mm, Common Electrode Layout,
Microcells with Quenching Mechanism Trench technology, 8 Dec 2005 Valeri Saveliev

11 SiPM Trench Technology
Cork University Study Result: the trenches reduce the probability that a crosstalk event occurs during the detection of an incident photon from 50% to below 1%. Measurements of the cross talk probability versus the distance between the pixels show an excellent agreement with the model. Trench Technology for preventing Optical Crosstalk, High Filling Factor (Geometrical Efficiency) 8 Dec 2005 Valeri Saveliev

12 Future Combination of the Sensors and FE Electronics in the same technology Process. 8 Dec 2005 Valeri Saveliev

13 New concept of Hadron Calorimeter System on Base Fe/Si structure
Tendency to build the Compact ILC Spectrometer, gives the possibility to thinking about full Fe/Si Hadron Calorimeter, analog or semidigital, The Basis for such Study is exist, problem mainly in cost, but probably time is enough… We are going to look on that. 8 Dec 2005 Valeri Saveliev

14 Plans Define the plans of activity in frame EUDET ,
Proposal in Russia for Funding from Russian Ministry of Education and Science 8 Dec 2005 Valeri Saveliev

15 SiPM Performance Dynamic Range – is defined by fine structure of SiPM
Low Photon Flux Spectrum P P Q1phe Identity of microcells is very high: the width of 1 phe peak is the distribution of signals from 1440 microcells due to photons is randomly distributed across the area of Si-PM Q2phe Q3phe Q4phe Dynamic Range – is defined by fine structure of SiPM ( and correspond 1500 photoelectrons) 8 Dec 2005 Valeri Saveliev

16 SiPM Performance Intrinsic Resolution
Q1phe Q2phe P Q3phe Q4phe Q5phe Q6phe Full Size SiPM – 1440 cells ( 20x30 microns) The Intrinsic Resolution of SiPM is very High (for 100 phe ~ few %) 8 Dec 2005 Valeri Saveliev